A.C. Cardiac defibrillator performance

  • F. Hepburn
Article
  • 67 Downloads

Abstract

An adequate expression of the desired characteristics is necessary for the assessment of commercially-available and privately-made defibrillators., The wide range of electrical performance of such units demands simple methods for measurement and possible modification. Observed performance characteristics are compared and subsidiary points of design mentioned. A simple instantaneous-electrode-current monitor is shown to be clinically useful and capable of giving rapid estimates of tissue resistance. It is also useful for assessment of defibrillator design and operation.

Sommaire

Une formule adéquate des caractéristiques recherchées est nécessaire pour évaluer l'efficacité d'un défibrillateur disponible dans le commerce ou construit individuellement. Les possibilités étendues des opérations électriques de tels instruments demandent l'application de méthodes simples aux mesures de contrôle et modifications possibles.

Les caractéristiques opérationnelles observées sont comparées entre elles et les détails du project d'ensemble sont décrits.

Une commande de contrôle simple fonctionnant avec un courant d'électrode instantané, apparaît utile en usage clinique et peut fournir une évaluation rapide de la résistance des tissus. Cette commande de contrôle trouve également son application dans l'évaluation des possibilités opérationnelles d'un défibrillateur et de la qualité de sa construction.

Zusammenfassung

Allgemeinverbindliche Charakteristiken sind für die Beurteilung von im Handel erhältlichen und durch Privatinitiative entwickelten Herzdefibrillatoren erforderlich. Der große anteil der elektrischen Ausrüstung dieser Geräte verlangt einfache Meßmethoden und Modifizierungsmöglichkeiten.

Die untersuchten Charakteristiken werden verglichen und auf zusätzliche Gesichtspunkte wird hingewiesen.

Ein einfaches Anzeigegerät für den Augenblickswert des Elektrodenstromes wird gezeigt. Dieses Gerät dürfte in klinischer Hinsicht von Nutzen sein sowie in ter Lage sein, schnelle Abschätzungen der Gewebewiderstände zu geben. Es kann ebenso für die Beurteilung der Ausführung und Leistungsfähigkeit von Defibrillatoren herangezogen werden.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Beck, C. S., Pritchard, W. H. andFeil, S. H. (1947) Ventricular fibrillation of long duration abolished by electric shock,J. Amer. med. Ass.,135, 985–986.Google Scholar
  2. Birnbaum, G. L. (1952) Simple cardiac defibrillator.J. Thorac. Surg.,23, 183–187.Google Scholar
  3. Guyton, A. C. andSatterfield, J. (1951) Factors concerned in electrical defibrillation of the heart particularly through the unopened chest.Amer. J. Physiol.,167, 81–87.Google Scholar
  4. Johnson, J., Kirby, C. K. andDripps, R. D. (1951) Defibrillation of the ventricles by electric shock with complete recovery.Ann. Surg.,134, 116–118.CrossRefGoogle Scholar
  5. Kouwenhoven, W. B., Milnor, W. R., Knickerbocker, G. G. andChesnut, W. R. (1957) Closed chest defibrillation of the heart.Surgery,42, 550–561.Google Scholar
  6. Leeds, S. E. (1953) Cardiac resuscitation.J. Amer. med. Ass.,152, 1409–1413.Google Scholar
  7. McMillan, I. K. R. (1955) Cardiac resuscitation.Brit. Med. Bull.,11, 229–232.Google Scholar
  8. McMillan, I. K. R., Cockett, F. B. andStyles, P. (1952) Cardiac arrest and ventricular fibrillation.Thorax,7, 205–212.CrossRefGoogle Scholar
  9. Mapleson, W. W. (1964) The design of defibrillating apparatus. Proc. Conf. on Resuscitation and Cardiac Pacing, Glasgow.Google Scholar
  10. Perry, B. J. andTrotman, R. E. (1958) An internal defibrillator with current measuring facilities.Electron. Engng.,30, 24–25.Google Scholar
  11. Shephard, R. J. (1961) The design of a cardiac defibrillator.Brit. Heart J.,23, 7–19.Google Scholar
  12. Zoll, P. M. andLinenthal, A. J. (1962) Termination of refractory tachycardia by external counter shock.Circulation,25, 596–603.Google Scholar
  13. Zoll, P. M., Linenthal, A. J., Gibson, W., Paul, M. H. andNorman, L. R. (1956a) Termination of ventricular fibrillation in man by externally applied counter shock.New Engl. J. Med.,254, 727–732.CrossRefGoogle Scholar
  14. Zoll, P. M., Linenthal, A. J. andNorman, L. R. (1960) Ventricular fibrillation.New Engl. J. Med.,262, 105–112.CrossRefGoogle Scholar
  15. Zoll, P. M., Paul, M. H., Linenthal, A. J., Norman, L. R. andGibson, W. (1956b) Effects of external electric currents on the heart.Circulation,14, 745–756.Google Scholar

Copyright information

© International Federation for Medical Electronics and Biological Engineering 1965

Authors and Affiliations

  • F. Hepburn
    • 1
  1. 1.Department of Medical Physics, The General InfirmaryUniversity of LeedsLeedsEngland

Personalised recommendations