Feasibility of using the automatic generating system for quartz watches as a leadless pacemaker power source

Article

Abstract

An automatic power-generating system (AGS) which converts kinetic energy into electric energy for quartz watches was tested as a power source for implantable cardiac pacemakers. An automatic power-generating mechanism and a capacitor (0.33 F) were removed from a quartz watch (SEIKO) and encapsulated in a polyvinyl case. Characteristics of the AGS were investigated by acceleration equipment. The capacitor in the AGS was charged to 2.0 V (0.66 J) by placing it on the equipment for about 30 minutes. The equipment has a 2 Hz cycle and generates ±1.7 G at the end of each half cycle. The AGS (fully charged to 2.0 V) was used as the power source for a pulse generator circuit built using commercially available CMOS IC. The circuit generated pulses of 0.5 ms width at 1 Hz (60 pulses min−1). The voltage of the AGS was maintained at 1.6 V while it was being charged by the accelerations. The generator supplied pulses of 0.75V, 1.47 mA through a 510Ω load. With fully charged AGS, the generator was also used to pace a mongrel dog's heart at 140 beats min−1 for 60 minutes. During pacing, the AGS supplied 420 mJ to the circuit and the cardiac muscle. The AGS was placed on the right ventricular wall of the mongrel dog under anaesthesia. Energy of 80 mJ is stored in a capacitor by the heart beating at about 200 beats/min for 30 minutes. Thus the AGS generated 13 μJ per heart beat. This result suggests that the AGS may supply enough energy for use in a cardiac pacemaker.

Keywords

Accelerated motion Automatic power-generating system Button-type pacemaker Capacitor Charging characteristic Discharging characteristic Energy Kinetic energy Leadless pacemaker Mechano-electric energy conversion system 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Alt, E., Barold, S. S., andStangl, K. (Eds) (1993): ‘Rate adaptive cardiac pacing’ (Springer-Verlag, Berlin, Heidelberg) pp. 318–331Google Scholar
  2. Crossley, G. H., Gayle, D. D., Simmons, T. W., Haisty, W. K., Bailey, J. R., Davis-O'Brien, K., Hammon, J. W., andFitzgerald, D. M. (1996): ‘Reprogramming pacemakers enhances longevity and is cost-effective’,Circulation,94, pp. 245–247Google Scholar
  3. Greatbatch, W., Holmes, C. F., Takeuchi, E. S., andEbel, S. J. (1996): ‘Lithium/carbon monofluoride (Li/CFx): a new pacemaker battery’,Pacing Clin. Electrophysiol.,19, pp. 1836–1840CrossRefGoogle Scholar
  4. Hayakawa, N. (1988): ‘A study of the new energy system for quartz watches (II)—The effective circuit for the system’, Proc. Congrès Européen de Chronométrie, C. E. C., pp. 81–85Google Scholar
  5. Kraus, M., Buckingham, T. A., andCandinas, R. (1997): ‘High thresholds may alter end-of-life behavior in a dual chamber pacemaker’,Pacing Clin. Electrophysiol.,20, pp. 1691–1697CrossRefGoogle Scholar
  6. Lanmuller, H., Bijak, M., Mayr, W., Rafolt, D., Sauermann, S., andThoma, H. (1997): ‘Useful applications and limits of battery powered implants in functional electrical stimulations’,Artif. Organs,21, pp. 1210–212Google Scholar
  7. Markewitz, A., Kronski, D., Kammeyer, A., Kaulbach, H., Weinhold, C., Doering, W., andReichart, B. (1995): ‘Determinants of dual chamber pulse generators longevity’,Pacing Clin. Electrophysiol.,18, pp. 2116–2120CrossRefGoogle Scholar
  8. Mond, H. G., andStokes, K. B. (1992): ‘The electrode-tissue interface: The revolutionary role of steroid elution’,PACE,15, pp. 95–107Google Scholar
  9. Preston, T. A., andBowers, D. L. (1974): ‘The automatic thresholds tracking pacemaker’,Med. Instrum.,8, pp. 322–325Google Scholar
  10. Schaldach, M., andFurman, S. (Ed.) (1975): ‘Longevity and pacemaker power sources’,in ‘Advances in pacemaker technology’ (Springer-Verlag), Chapter 5Google Scholar
  11. Schuchert, A., andKuck, K. H. (1994): ‘Influence of internal current and pacing current on pacemaker longevity’,Pacing Clin. Electrophysiol.,17,(1), pp. 13–16CrossRefGoogle Scholar
  12. Suma, K. (Ed.) (1996): ‘Pacemaker data book’ (Japan Publications)Google Scholar
  13. Toyoshima, T. (1997): ‘Batteries for implantable medical devices’,Clin. Eng.,8, pp. 734–741Google Scholar
  14. Yasukawa, N., andNagao, S. (1986): ‘A study of the new energy system for quartz watches’, Proc. Congrès de Chronométrie, La Chaux-de-Fonds, pp. 15–18Google Scholar

Copyright information

© IFMBE 1999

Authors and Affiliations

  1. 1.Research Institute of ElectronicsShizuoka UniversityHamamatsuJapan
  2. 2.Hamamatsu University School of MedicineHamamatsuJapan

Personalised recommendations