Real-time measurement of pulse wave velocity from arterial pressure waveforms

  • M. W. Ramsey
  • W. R. Stewart
  • C. J. H. Jones
Physiological Measurement

Abstract

Instrumentation for the real-time clinical measurement of pulse wave velocity (PWV) from intra-arterial pressure waveforms is presented. The time delay between pressure waveforms (obtained from two intra-arterial catheter-mounted transducers 5 cm apart) is calculated by a transputer using multiple comparisons between discrete sections of the waveforms. The method is validated by analysis of digital and analogue signals with known time delays and is used to measure changes in PWV in the right common iliac artery (RCIA) during infusions of acetylcholine (2·4, 24 and 240 μg ml−1) in six healthy subjects. The system measures the delay between digitally shifted triangular waveforms and pressure waveforms to a precision of about 50 μs, and it is superior to measurements performed by hand using a high-performance digital storage oscilloscope. When used to measure the effects of acetylcholine on the RCIA, dose-dependent reductions in PWV are recorded (−8·5%, −11·6%, −14·5%). It is concluded that the instrumentation enables PWV to be measured with high accuracy and precision in real time, if the pressure signals are of high fidelity and the relative amplification of the signals is carefully balanced.

Keywords

Algorithms Computer systems Haemodynamics 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Avolio, A. P., Chen, S., Wang, R., Zhang, C., Li, M., andO’Rourke, M. F. (1983): ‘Effects of aging on changing arterial compliance and left ventricular load in a northern Chinese urban community’,Circ.,68, pp. 50–58Google Scholar
  2. Benthin, M., Dahl, P., Ruzica, R., andLindström, K. (1991): ‘Calculation of pulse-wave velocity using cross-correlation—effects of reflexes in the arterial tree’,Ultrasound Med. Biol.,17, pp. 461–469.CrossRefGoogle Scholar
  3. Bland, J. M., andAltman, D. G. (1986): ‘Statistical methods for assessing agreement between two methods of clinical measurement’,Lancet,1, pp. 307–310Google Scholar
  4. Bramwell, J. C., Hill, A. V., andMcSwiney, B. A. (1923): ‘The velocity of the pulse wave in man in relation to age as measured by the hot-wire sphygmograph’,Heart,10, pp. 233–255Google Scholar
  5. Caro, C. G., Pedley, J. G., Schroter, R. C., andSeed, W. A. (1978): ‘The mechanics of the circulation’ (Oxford University Press)Google Scholar
  6. Evans, D. H. (1988): ‘A pulse foot-seeking algorithm for Doppler ultrasound waveforms’,Clin. Phys. Physiol. Meas.,9, pp. 267–271CrossRefGoogle Scholar
  7. Gribbin, B., Pickering, T. G., andSleight, P. (1979): ‘Arterial distensibility in normal and hypertensive man’,Clin. Sci.,56, pp. 413–417Google Scholar
  8. Inmos (1989): ‘The transputer applications notebook: systems and performance’, Inmos Ltd., Bristol, UK.Google Scholar
  9. Jaffrin, M. Y., andVanhoutte, C. (1979): ‘Quantitative interpretation of arterial impedance plethysmographic signals’,Med. Biol. Eng. Comput.,17, pp. 2–10CrossRefGoogle Scholar
  10. Jones, C. J. H., Parker, K. H., Hughes, R., andSheridan, D. J. (1991): ‘Non-linearity of human arterial pulse wave transmission’,ASME J. Biomech. Eng.,114, pp. 10–14Google Scholar
  11. Manning, G. K., andDripps, J. H. (1986): ‘Comparison of correlation and modulus difference processing algorithms for the determination of foetal heart rate from ultrasonic Doppler signals’,Med. Biol. Eng. Comput.,24, pp. 121–129CrossRefGoogle Scholar
  12. McDonald, D. A. (1976): ‘Regional pulse-wave velocity in the arterial tree’,J. Appl. Physiol.,24, pp. 73–78Google Scholar
  13. McDonald, D. A. (1974): ‘Blood flow in arteries’ (Edward Arnold, London)Google Scholar
  14. Milnor, W. R. (1989): ‘Hemodynamics’ (Williams and Wilkins, Baltimore) 2nd edn.Google Scholar
  15. Nichols, W. W. andO’Rourke, M. F. (1990): ‘McDonald’s blood flow in arteries: theoretical, experimental and clinical principles’ (Edward Arnold, London) 3rd edn.Google Scholar
  16. Nye, E. R. (1964): ‘The effect of blood pressure alteration on the pulse wave velocity’,Br. Heart J.,26, pp. 261–265Google Scholar
  17. Okada, M., andKimura, S. (1986): ‘Estimation of arterial pulse wave velocities in the frequency domain: method and clinical considerations’,Med. Biol. Eng. Comput.,24, pp. 255–260CrossRefGoogle Scholar
  18. Press, W. H., Flannery, B. P., Teukolsky, S. A., andVetterling, W. T. (1988): ‘Numerical recipes in C: the art of scientific computing’, (Cambridge University Press)Google Scholar
  19. Stewart, W. R., Ramsey, M. W., andJones, C. J. H. (1994): ‘Noninvasive measurement of pulse wave velocity using transputer based analysis of Doppler flow audio signals’,Physiol. Meas.,15, pp. 299–307CrossRefGoogle Scholar
  20. Tardy, Y., Vieyres, P. P., andMeister, J.-J. (1990): ‘Assessment of the true pulse-wave velocity over the physiological pressure range’. 12th Ann. Int. Conf. of the IEEE Engineering in Medicine and Biology Society, Philadelphia, Pennsylvania, vol. 12, pp. 1817–1818Google Scholar
  21. Toto-Moukouo, J. J., Achimastos, A., Asmar, R. G., Hugues, C. J., andSafar, M. E. (1986): ‘Pulse wave velocity in patients with obesity and hypertension’,Am. Heart J.,112, pp. 136–140CrossRefGoogle Scholar
  22. Weinmann, J., andSapoznikov, D. (1971): ‘Equipment for continuous measurements of pulse wave velocities’,Med. Biol. Eng. Comput.,9, pp. 125–138CrossRefGoogle Scholar
  23. Wright, J. S., Cruickshank, J. K., Kontis, S., Dore, C., andGosling, R. G. (1990): ‘Aortic compliance measured by noninvasive Doppler ultrasound: description of a method and its reproducibility’,Clin. Sci.,78, pp. 463–468Google Scholar

Copyright information

© IFMBE 1995

Authors and Affiliations

  • M. W. Ramsey
    • 1
  • W. R. Stewart
    • 2
  • C. J. H. Jones
    • 1
  1. 1.Department of CardiologyUniversity of Wales College of MedicineCardiffUK
  2. 2.Department of BioengineeringUniversity of Wales College of MedicineCardiffUK

Personalised recommendations