Advertisement

Materials and Structures

, Volume 30, Issue 9, pp 527–532 | Cite as

Thermally induced softening and cracking in concrete with minimal reinforcement

  • Agnes Nagy
Scientific Reports

Abstract

This paper deals with modeling of softening and cracking induced by non-uniform cooling or shrinkage of reinforced concrete. Concrete and reinforcement are described by a set of constitutive equations and cooling is assumed to be a linear thermal diffusion process. The investigated structure is a medium-thick wall with external restraint modeled by springs. The main purpose of the paper is to study the role and the amount of the socalled minimum reinforcement necessary to control cracking. Another purpose is to find the force actually arising in the wall during cooling and also to compute the range of softening and cracking of the concrete. Sensitivity of the results is studied in a parametric investigation.

Keywords

Minimum Reinforcement Failure Region Material Region Spring Coefficient Tension Softening 

Résumé

Cet article traite de la modélisation du radoucissement et de la fissuration dus au refroidissement non uniforme ou au retrait du béton armé. Le béton et son renforcement sont décrits par un ensemble d'équations constitutives et le refroidissement est présumé être un processus linéaire de diffusion thermique. La structure étudiée est un mur d'épaisseur moyenne retenu à l'extérieur par des ressorts. L'objectif principal de cet article est d'étudier le rôle et la quantité minimale d'armature nécessaire pour le contrôle de la fissuration. Un deuxième objectif est de déterminer la force réelle qui monte dans le mur pendant le refroidissement et de calculer l'étendue du ramollissement et de la fissuration du béton. Une investigation paramétrique étudie la sensibilité des résultats.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. [1]
    CEB, ‘Design Manual on Cracking and Deformations’, No. 158 (1985).Google Scholar
  2. [2]
    Jaccoud, J.P., Francou, B. and Camara, J.M., ‘Armature minimale pour le contrôle de la fissuration’, Institut de Statique et Structures, École Polytechnique Fédérale de Lausanne, Mai 1984.Google Scholar
  3. [3]
    Jaccoud, J.P. and Charid, H., ‘Armature minimale pour le contrôle de la fissuration’, Institut de Statique et Structures, École Polytechnique Fédérale de Lausanne, Essais Série C, Publication IBPA No. 109, 114, Septembre 1985.Google Scholar
  4. [4]
    Jaccoud, J.P., ‘Armature minimale pour le contrôle de la fissuration des structures en béton’, École Polytechnique Fédérale de Lausanne, Thèse No 666, 1987.Google Scholar
  5. [5]
    Iványi, Gy., ‘Bemerkungen zur “Mindestbewehrung’ in Wänden’,Beton- und Stahlbetonbau 90 Heft11 (1995).CrossRefGoogle Scholar
  6. [6]
    Thelandersson, S. and Mårtensson, A., ‘Effect on Tension Softening and Cracking on Drying Shrinkage of Concrete’, Report TVMS-7041, Division of Structural Mechanics, Lund, 1987.Google Scholar
  7. [7]
    Thelandersson, S., Mårtensson, A. and Dahlblom, O., ‘Tension softening and cracking in drying concrete’,Mater. Struct. 21 (1988) 416–424.CrossRefGoogle Scholar
  8. [8]
    Nagy, A., ‘Cracking of Concrete Structures Due to Early Thermal Deformations’, Report TVBK-1009, Division of Structural Engineering, Lund, 1994.Google Scholar
  9. [9]
    Luikov, A.V., ‘Analytical Heat Diffusion Theory’ (Academic Press, New York, 1968).Google Scholar
  10. [10]
    Nagy, A., ‘Softening and Cracking Due to Colling in Concrete Provided with Supplementary Reinforcement’, Report TVBK-7050, Division of Structural Engineering, Lund, 1995.Google Scholar
  11. [11]
    Karihallo, L. B., ‘Fracture Mechanics and Structural Concrete’ (Longiman Scientific & Technical, 1995).Google Scholar

Copyright information

© RILEM 1997

Authors and Affiliations

  • Agnes Nagy
    • 1
  1. 1.Department of Structural EngineeringLund Institute of TechnologySweden

Personalised recommendations