High-resolution recordings of thePR segment in magnetocardiography

  • S. N. Erné
  • R. R. Fenici
  • H. D. Hahlbohm
  • M. Masselli
  • H. P. Lehmann
  • Z. Trontelj
Article

Summary

ThePR interval of magnetocardiograms has been measured with a SQUID sensor in the Berlin magnetically shielded room. In addition to previously reported ramps with isolated superimposed signals in several cases a structured morphology has been found.

PACS. 87.40

Biomagnetism (including magnetocardiography) 

PACS. 85.25

Superconducting devices superconducting magnets 

Riassunto

Il magnetocardiogramma ad alta risoluzione è stato registrato mediante magnetometri superconduttori in 12 volontari sani utilizzando la camera schermata di Berlino per ridurre il livello di rumore elettromagnetico. La morfologia del trattoPR magnetico è caratterizzata dalle «rampe» in precedenza osservate, sulle quali s’inseriscono segnali. A volte la forma d’onda appare complessa.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. (1).
    S. N. Erné, R. R. Fenici, H.-D. Halbohm, H. P. Lehmann andZ. Trontelj:High-resolution magnetocardiography: Recording of His-Purkinje activity in man, inProceedings of the IX International Congress of Electrocardiography, Suppl., to be published onJpn. Heart J. Google Scholar
  2. (2).
    A. Mager:The Berlin magnetically shielded room (BMSR),Section A:Design and construction, inBiomagnetism, edited byS. N. Erné, H.-D. Hahlbohm andH. Lübbig (Berlin and New York, N. Y., 1981), p. 51.Google Scholar
  3. (3).
    S. N. Erné, H.-D. Hahlbohm, H. Scheer andZ. Trontelj:The Berlin magnetically shielded room (BMSR),Section B:Performance, inBiomagnetism, edited byS. N. Erné, H.-D. Hahlbohm andH. Lübbig (Berlin and New York, N. Y., 1981), p. 79.Google Scholar
  4. (4).
    R. Fenici, G. L. Romani, S. Barbanera, P. Zeppilli, P. Carelli andI. Modena:G. Ital. Cardiol.,10, 1366 (1980).Google Scholar
  5. (5).
    D. E. Farrell, J. H. Tripp andR. Nordgren:IEEE Trans. Biomed. Eng., BME-27, 345 (1980).Google Scholar
  6. (6).
    S. Barbanera, P. Carelli, R. Fenici, R. Leoni, I. Modena andG. L. Romani:IEEE Trans. Magn.,17, 849 (1981).CrossRefGoogle Scholar
  7. (7).
    M. Saarinen, P. Siltanen, P. J. Karp andT. E. Katila:Ann. Clin. Res. Suppl.,10, No. 21, 1 (1978).Google Scholar
  8. (8).
    S. N. Erné, H.-D. Hahlbohm andJ. Palow:The Berlin magnetically shielded room (BMSR),Section C:Periphery, inBiomagnetism, edited byS. N. Erné, H.-D. Hahlbohm andH. Lübbig (Berlin and New York, N. Y., 1981), p. 89.Google Scholar

Copyright information

© Società Italiana di Fisica 1983

Authors and Affiliations

  • S. N. Erné
    • 1
  • R. R. Fenici
    • 1
  • H. D. Hahlbohm
    • 1
  • M. Masselli
    • 1
  • H. P. Lehmann
    • 1
  • Z. Trontelj
    • 1
  1. 1.Physikalisch-Technische BundesanstaltInstitut BerlinBerlin 10

Personalised recommendations