Evaluation of blood resistivityin vivo for impedance cardiography in man, dog and rabbit

  • F. M. Traugott
  • A. W. Quail
  • S. W. White
Article

Abstract

The accuracy of impedance cardiography for measurement of stroke volume (SV2) has been controversial. This could be, in part, due to the use in the Kubicek formula of the bench-determined blood resistivity (ϱ)-haematocrit (Hct) relationship, which does not take into account factors such as complex blood-velocity movements. In the present studyin vivo, ϱ was calculated in dog, rabbit and man from the rearranged Kubicek formula, ϱ=(SV. Zo2)/(L2. dZ/dt max T); the stroke volumes used in the calculation being derived at different Hcts in the different species from the independent techniques of electromagnetic flowmeter, direct Fick, and direct Fick and thermodilution, respectively. Thein vivo ϱ-Hct relationship is linear, inverse and nearly constant over the range of Hcts tested (dog 26–62%, man 31–48%, rabbit 37%). No significant difference exists between meanin vivo ϱ values determined for the three species at corresponding haematocrits despite different thoracic anatomy and circulatory dynamics. Thus, the best estimate of mean ϱin vivo within the normal Hct range is 135Ω cm, the use of which will result in a SV2 accuracy of better than ±10%.

Keywords

Blood resistivityin vivo Cardiac output Haematocrit Impedance Cardiography Stroke volume 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Baker, L. E., Judy, W. V., Geddes, L. A., Langley, F. M. andHill, D. W. (1971) The measurement of cardiac output by means of electrical impedance.Cardiovasc. Res. Center Bull.,9, 135–145.Google Scholar
  2. Denniston, J. C., Maher, J. T., Reeves, J. T., Cruz, J. C., Cymerman, A. andGrover, R. F. (1976) Measurement of cardiac output by electrical impedance at rest and during exercise.J. Appl. Physiol. 40, 91–95.Google Scholar
  3. Frewer, R. A. (1974) The electrical conductivity of flowing blood.Biomed. Eng.,9, 552–555.Google Scholar
  4. Geddes, L. A. andBaker, L. E. (1967) The specific resistance of biological material—a compendium of data for the biomedical engineer and physiologist.Med. & Biol. Eng.,5, 271–293.Google Scholar
  5. Geddes, L. A. andSadler, C. (1973) The specific resistance of blood at body temperature.Med. & Biol. Eng.,11, 336–339.Google Scholar
  6. Hill, D. W. andThompson, F. D. (1975a) The effect of haematocrit on the resistivity of human blood at 37°C and 100 KHz.Med. & Biol. Eng.,13, 182–186.Google Scholar
  7. Hill, D. W. andThompson, F. D. (1975b) The importance of blood resistivity in the measurement of cardiac output by the thoracic impedance method.Med. & Biol. Eng.,13, 187–191.Google Scholar
  8. Kelman, G. R. andNunn, J. F. (1966) Nomograms for correction of bloodpO2,pCO2, pH and base excess for time and temperature.J. Appl. Physiol.,21, 1484–1490.Google Scholar
  9. Kubicek, W. G., Karnegis, J. N., Patterson, R. P., Witsoe, D. A. andMattson, R. H. (1966) Development and evaluation of an impedance cardiac output system.Aerospace Med.,37, 1208–1212.Google Scholar
  10. Kubicek, W. G., From, A. H. L., Patterson, R. P., Witsoe, D. A., Castaneda, A., Lillehei, R. C. andErsek, R. (1970) Impedance cardiography as a noninvasive means to monitor cardiac function.J. Assoc. Advanc. Med. Instrument,4, 79–84.Google Scholar
  11. Liebman, J. P., Pearl, J. andBagno, S. (1962) The electrical conductance properties of blood in motion.Physics Med. Biol.,7, 177–194.CrossRefGoogle Scholar
  12. Mohapatra, S. N., Costeloe, K. L. andHill, D. W. (1977) Blood resistivity and its implications for the calculation of cardiac output by the thoracic electrical impedance technique.Intens. Care Med.,3, 63–67.CrossRefGoogle Scholar
  13. Pate, T. D., Baker, L. E. andRosborough, J. P. (1975) The simultaneous comparison of the electrical impedance method for measuring stroke volume and cardiac output with four other methods.Cardiovasc. Res. Bull.,14, 39–52.Google Scholar
  14. Patterson, R. P. (1965) Cardiac output determinations using impedance, plethysmography.M.S.E.E. thesis, University of Minnesota.Google Scholar
  15. Sokal, R. R. andRohlf, R. J. (1969)Biometry, San Francisco, W. H. Freeman, 405–468.Google Scholar
  16. Visser, K. R., Lamberts, R., Korstein, H. H. M. andZijlstra, W. G. (1976) Observations on blood flow related electrical impedance changes in rigid tubes.Pflugers Arch.,366, 289–291.CrossRefGoogle Scholar

Copyright information

© IFMBE 1981

Authors and Affiliations

  • F. M. Traugott
    • 1
  • A. W. Quail
    • 2
  • S. W. White
    • 3
    • 4
  1. 1.National Health & Medical Research Council of AustraliaAustralia
  2. 2.National Health & Medical Research Council of AustraliaAustralia
  3. 3.Faculty of MedicineUniversity of NewcastleAustralia
  4. 4.Department of AnaestheticsThe Royal Newcastle HospitalNewcastleAustralia

Personalised recommendations