High-quality recording of bioelectric events

Part 1 Interference reduction, theory and practice
  • A. C. Metting van Rijn
  • A. Peper
  • C. A. Grimbergen
Review

Abstract

In the first part of the review the various mechanisms that could be the cause of interference in bioelectric recordings are considered. It is demonstrated that the performance of a good amplifier can be seriously degraded in its functioning if the whole measurement situation is not taken into account. Several techniques used to reduce interference, of which guarding and driven right leg circuits are the most important, are analysed. In the second part of the review some examples of the application of the theory in practical situations are presented. The instrumentation amplifier circuit normally used in bioelectric recordings is improved for measurements under difficult circumstances. Another application is a low-cost 64-channel amplifier for multichannel ECG recordings. The third application is a device that can be added to bioelectric measurement systems and will provide a major reduction in interference.

Keywords

Bioelectric recordings Driven right leg Guarding Interference Isolation 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Almasi, J. J. andSmith, O. H. (1970) Systemic and random variations of ECG electrode impedance.Ann. NY Acad. Sci.,170, 509–519.Google Scholar
  2. Forster, I. C. (1974) Measurement of patient body capacitance and a method of patient isolation in mains environments.Med. & Biol. Eng.,12, 730–732.Google Scholar
  3. Geddes, L. A. andBaker, L. E. (1966a) Chlorided silver electrodes.Med. Res. Eng.,6, 33–34.Google Scholar
  4. Geddes, L. A. andBaker, L. E. (1966b) The relationship between input impedance and electrode area in recording the ECG.Med. & Biol. Eng.,4, 439–450.Google Scholar
  5. Geddes, L. A. (1972)Electrodes and the measurements of bioelectric events. Wiley Interscience, New York, 44–94.Google Scholar
  6. Grimnes, S. (1983) Impedance measurements of individual skin surface electrodes.Med. & Biol. Eng. & Comput.,21, 750–755.CrossRefGoogle Scholar
  7. Hamstra, G. H., Peper, A. andGrimbergen, C. A. (1984) Low-power, low-noise instrumentation amplifier for physiological signals.,22, 272–274.CrossRefGoogle Scholar
  8. Huhta, J. C. andWebster, J. G. (1973) 60-Hz interference in electro-cardiography.IEEE Trans.,BME-20, 91–101.Google Scholar
  9. McClellan, A. D. (1981) Extracellular amplifier with boot-strapped input stage results in high common-mode rejection.Med. & Biol. Eng. & Comput.,19, 657–658.CrossRefGoogle Scholar
  10. Morrison, R. (1977)Grounding and shielding techniques in instrumentation, 2nd edn. John Wiley & Sons, New York, 132–133.Google Scholar
  11. Motchenbacher, C. D. andFitchen, F. C. (1972)Low-noise electronic design. John Wiley & Sons, New York, 185–187.Google Scholar
  12. Olson, W. H. (1978) Electrical safety. InMedical instrumentation: application and design.Webster, J. G. (Ed.), Houghton Mifflin Co., Boston, 667–706.Google Scholar
  13. Pacela, A. F. (1967) Collecting the body's signals.Electronics,40, 103–112.Google Scholar
  14. Pallas-Arény, R. (1988) Interference-rejection characteristics of biopotential amplifiers: a comparative analysis.IEEE Trans.,BME-35, 953–959.Google Scholar
  15. Peper, A., Jonges, R., Losekoot, T. G. andGrimbergen, C. A. (1985) Recording of surface His-Purkinje potentials.Med. & Biol. Eng. & Comput.,23, 365–376.CrossRefGoogle Scholar
  16. Reek, E. J., Grimbergen, C. A. andvan Oosterom, A. (1984) A low-cost 64 channel microcomputer based data acquisition system for bedside registration of body surface maps. Proc. 11th Int. Congr. Electrocardiol., Caen, France, 17th–20th July, 37–38.Google Scholar
  17. Smit, H. W., Verton, K. andGrimbergen, C. A. (1987) A low-cost multichannel preamplifier for physiological signals.IEEE Trans. BME-34, 307–310.Google Scholar
  18. Spekhorst, H., SippensGroenewegen, A., David, G. K., Metting van Rijn, A. C. andBroekhuysen, P. (1988) Radiotransparent carbon fibre electrode for ECG recordings in the catheterization laboratory.BME-35, 402–406.Google Scholar
  19. Thakor, N. V. andWebster, J. G. (1980) Ground-free ECG recording with two electrodes..BME-27, 699–704.Google Scholar
  20. Tobey, G. E., Graeme, J. G. andHuelsman, L. P. (1971)Operational amplifiers: design and applications. McGraw-Hill, New York, 206–207.Google Scholar
  21. Winter, B. B. andWebster, J. G. (1983) Driven-right-leg circuit design.IEEE Trans.,BME-30, 62–66.Google Scholar

Copyright information

© IFMBE 1990

Authors and Affiliations

  • A. C. Metting van Rijn
    • 1
  • A. Peper
    • 1
  • C. A. Grimbergen
    • 1
  1. 1.Laboratory of Medical PhysicsUniversity of Amsterdam, Academic Medical CentreAmsterdamThe Netherlands

Personalised recommendations