Abstract
Disposal of Department of Energy (DOE) radioactive waste into repositories such as the Waste Isolation Pilot Plant (WIPP) and the Nevada Test Site (NTS) requires characterization to ensure regulatory and transportation requirements are met and to collect information regarding chemistry of the waste for processing concerns. Recent addition of an inductively coupled plasma quadrupole mass spectrometer in a radioactive contaminated laboratory at the Oak Ridge National Laboratory (ORNL) has allowed the evaluation of advantages of using ICP-MS over traditional techniques for some of these characterization needs. The measurement of long-lived beta nuclides (i.e.99Tc) by ICP-MS has resulted in improved detection limits and accuracy than the traditional counting techniques as well as reducing the need for separation/purification techniques which increase personnel exposure to radiation. Using ICP-MS for the measurement of U isotopes versus the traditional Thermal Ionization Mass Spectrometer (TIMS) technique has reduced cost and time by more than half while still maintaining the needed accuracy to determine risk assessment of the waste tanks. In addition, the application of ICP-MS to ORNL waste tank characterization has provided the opportunity to estimate non-routine radionuclides (i.e.135Cs and151Sm) and non-routine metals (i.e. Li, Ti, rare earths, etc.) using a rapid low cost screening method. These application methodologies and proficiencies on ORNL waste samples are summarized throughout the paper.
Similar content being viewed by others
References
J. M. Keller, J. M. Giaquinto, A. M. Meeks, Characterization of the MVST Waste Tanks Located at ORNL, ORNL/TM-13357, Oak Ridge National Laboratory, 1996.
J. M. Keller, J. M. Giaquinto, A. M. Meeks, Characterization of the OHF Waste Tanks Located at ORNL, ORNL/TM-13394, Oak Ridge National Laboratory, 1997.
U.S. Environmental Protection Agency, Test Methods for Evaluating Solid Waste, SW-846, 3rd ed., July 1992.
D. M. Beals, J. Radioanal. Nucl. Chem., 204 (1996) 253.
M. Noé, A. Hérès Applications of Inductively Coupled Plasma-Mass Spectrometry to Radionuclide Determinations ASTM, 1995, p. 29.
W. R. Kinard, N. E. Bibler, C. J. Coleman, R. A. Dewberry, W. T. Boyce, S. B. Wyrick, Applications of Inductively Coupled Plasma-Mass Spectrometry to Radionuclide Determinations, ASTM, 1995, p. 48.
National Academy of Sciences, The Radiochemistry of the Rare Earths Scandium, Yttrium, and Actinium, NAS-NS 3020, U.S. AEC, 1961.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Meeks, A.M., Giaquinto, J.M. & Keller, J.M. Application of ICP-MS radionuclide analysis to “Real World” samples of department of Energy radioactive waste. J Radioanal Nucl Chem 234, 131–136 (1998). https://doi.org/10.1007/BF02389760
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF02389760