Medical and Biological Engineering and Computing

, Volume 40, Issue 5, pp 506–511 | Cite as

Neonatal lungs: Maturational changes in lung resistivity spectra

  • B. H. BrownEmail author
  • R. A. Primhak
  • R. H. Smallwood
  • P. Milnes
  • A. J. Narracott
  • M. J. Jackson
Article

Abstract

The electrical resistivity of lung tissue can be related to the structure and composition of the tissue and also to the air content. Electrical impedance tomographic measurements have been used on 155 normal children over the first three years of life and 25 pre-term infants, to determine the absolute resistivity of lung tissue as a function of frequency. The results show consistent changes with increasing age in both lung tissue resistivity (5.8Ωm at birth to 20.9Ωm at 3 years of age) and in the changes of resistivity with frequency (Cole parameter ratio R/S=0.41 at birth and 0.84 at 3 years of age). Comparison with a lung model showed that the measurements are consistent with maturational changes in the number and size of alveoli, the extracapillary blood volume and the size of the extracapillary vessels. However, the results show that the process of maturation is not complete at the age of three years.

Keywords

Lung Resistivity spectra Bio-impedance Neonatal lungs Tissue modelling 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Barber, D. C., andSeagar, A. D. (1987): ‘Fast reconstruction of resistance images’,Clin. Phys. Physiol. Meas.,8, pp. 47–54CrossRefGoogle Scholar
  2. Boyd, E. (1962): ‘Growth, including reproduction and morphological development’, inAltman, andDittmer (Eds), ‘Biological handbooks, federation of American societies for experimental biology’ (Washington, 1962), pp. 346–348Google Scholar
  3. Brown, B. H., Primhak, R. A., Smallwood, R. H., Milnes, P., Narracott, A. J., andJackson, M. J. (2002): ‘Neonatal lungscan absolute lung resistivity be measured non-invasively?,Med. Biol. Eng. Comput.,40, pp. 388–394Google Scholar
  4. Cole, K. S., andCole, R. H. (1941): ‘Dispersion and absorption in dielectrics’,J. Chem. Phys.,9, pp. 341–351Google Scholar
  5. Hampshire, A. R. (1997): ‘Neonatal electrical impedance tomographic spectroscopy’, PhD thesis, University of Sheffield, UKGoogle Scholar
  6. Lu, L., Brown, B. H., Barber, D. C., andLeathard, A. D. (1995): ‘A fast parametric modelling algorithm with the Powell method’,Physiol. Meas.,16, pp. 39–48CrossRefGoogle Scholar
  7. Nopp, P., Harris, N. D., Zhao, T. X., andBrown, B. H. (1997): ‘Model for the dielectric properties of human lung tissue against frequency and air content’,Med. Biol. Eng. Comput.,35, pp. 695–702Google Scholar
  8. Primhak, R. A., Brown, B. H., Jackson, M. J., Milnes, P., andSmallwood, R. H. (2001): ‘Maturational changes in lung impedance’,Proc. XIth International Conference on Electrical Bioimpedance Oslo, ISBN 82-91853-05-3, pp. 297–300Google Scholar
  9. Schibler, A., andHenning, R. (2001): ‘Measurement of functional residual capacity in rabbits and children using an ultrasonic flow meter’,Pediatric Research,49, pp. 581–588Google Scholar
  10. Smallwood, R. A., Hampshire, A. R., Brown, B. H., Primhak, R. A., Marven, S., andNopp, P. (1999): ‘A comparison of neonatal and adult lung impedances derived from EIT images’,Physiol. Meas,20, pp. 401–413CrossRefGoogle Scholar
  11. Wilson, A. J., Milnes, P., Waterworth, A., andBrown, B. H. (2001): ‘MK3.5 a modular, multi-frequency successor to the Mk3a EIS/EIT system’,Physiol. Meas.,22, pp. 49–54CrossRefGoogle Scholar
  12. Witsoe, D. A., andKinnen, E. (1967): ‘Electrical resistivity of lung at 100 kHz’,Med. Biol. Eng. Comput.,5, pp. 239–247Google Scholar
  13. Zeltner, T. B., Caduff, J. H., Gehr, P., Pfenninger, J., andBurri, P. H. (1987): ‘The postnatal development and growth of the human lung. I: Morphometry’,Resp. Physiol.,67, pp. 247–267Google Scholar
  14. Zhao, T. X. (1996): ‘New applications of electrical impedance of human blood’,J. Med. Eng. and Tech.,20: pp. 115–120Google Scholar

Copyright information

© IFMBE 2002

Authors and Affiliations

  • B. H. Brown
    • 1
    Email author
  • R. A. Primhak
    • 2
  • R. H. Smallwood
    • 1
  • P. Milnes
    • 1
  • A. J. Narracott
    • 1
  • M. J. Jackson
    • 2
  1. 1.Medical Physics & Clinical EngineeringUniversity of Sheffield, Royal Hallamshire HospitalSheffieldUK
  2. 2.Child HealthUniversity of SheffieldSheffieldUK

Personalised recommendations