Journal of Radioanalytical and Nuclear Chemistry

, Volume 125, Issue 1, pp 127–134

Radiation dosimetry using clear PMMA and PVC in the range of 5–45 kGy

  • Hasan M. Khan
  • Gulzar Ahmad
  • A. Sattar
  • S. K. Durrani
Article

Abstract

Some plastic sheets manufactured or commercially available in Pakistan have been tested as radiation dosimeters for cobalt-60 γ-rays. Radiation induced colouration in the plastics have been measured spectrophotometrically. The results show that 2 mm thick clear poly(methyl methacrylate) (PMMA) can be used as radiation dosimeter up to 45 kGy when absorption measurements are made at 305 nm and 314 nm; whereas 1 mm thick clear poly(vinylchloride) (PVC) is useful up to 30 kGy when measured at 396 nm. The response of PMMA dosimeter is stable for at least 15 days and that for PVC for 30 days, when stored under ambient conditions after irradiation. Post-irradiation stability at various temperatures (−10 to 55°C) has also been studied.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Copyright information

© Akadémiai Kiadó 1988

Authors and Affiliations

  • Hasan M. Khan
    • 1
  • Gulzar Ahmad
    • 1
  • A. Sattar
    • 2
  • S. K. Durrani
    • 2
  1. 1.National Centre of Excellence in Physical ChemistryUniversity of PeshawarPeshawar(Pakistan)
  2. 2.Nuclear Institute for Food and AgriculturePeshawar(Pakistan)