Skip to main content
Log in

A flow ultramicroscope for particle counting and size distribution analysis

  • Published:
Colloid and Polymer Science Aims and scope Submit manuscript

Summary

A machine is described which will count particles or droplets in suspension in a liquid down to 0.1 μm and which is capable of size measurements between 0.1 μm and 2.0 ,μm. It works on the basis of the flow ultramicroscope. A stream of particles is passed through a laser beam and as each one passes a pulse of scattered light is produced. The pulses are detected by a photomultiplier and can be counted. Additionally the intensity of the pulses can be measured and a size distribution built up for the particles.

The absolute accuracy of the machine has been checked by calibration against narrow size distribution polystyrene latexes and plots of intensity vs. size are found to conform with theory.

Zusammenfassung

Die Arbeit stellt ein Gerät, geeignet für Teilchenzählung von einer Größenordnung bis 0.1 μm, vor. Es funktioniert auf Art eines Fließ-Ultramikroskops mit dem Unterschied, daß Teilchengrößenbestimmungen in dem Bereich von 0.1 bis 2.0 μm möglich sind, was mit anderen Geräten nicht der Fall ist.

Die Teilchen fließen durch ein mit Laserlicht beleuchtetes Meßvolumen (Küvette). Das von ihnen gestreute Licht erzeugt Impulse, die mit Hilfe eines Photomultiplikators gezählt werden können. Die Intensität des von einem Teilchen gestreutes Licht hängt von dessen Größe ab und deshalb wird die Bestimmung einer Größenverteilung möglich.

Die absolute Genauigkeit des Gerätes bestimmt man durch Vergleich mit einer engen Größenverteilung Polystyrol Latex. Ergebnisse zeigen, daß der Verlauf der Intensität in Abhängigkeit von Teilchengrößen mit der Theorie gut übereinstimmt.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Derjaguin, B. V., G. Ja. Vlasenko, J. Coll. Sci.17, 605 (1962).

    Google Scholar 

  2. McFadyen, P., A. L. Smith, J. Coll. Inter. Sci.45, 573 (1973).

    Google Scholar 

  3. Smith, A. L., R. Duckworth, Private Communication, Unilever Research Ltd., Port Sunlight, Wirral, Merseyside.

  4. Leohr, G., R. Reinecke, Die Ang. Mak. Chem.85, 181 (1980).

    Google Scholar 

  5. Kerker, M., “The Scattering of Light and Other Electromagnetic Radiation”, Academic Press (1969).

  6. Gucker, F. T., J. Tuma, J. Coll. Inter. Sci.27, 402 (1968).

    Google Scholar 

  7. Jones, A. R., Personal Communication, Department of Chemical Engineering and Chemical Technology, Imperial College, London.

  8. Goodwin, J. W., J. Hearn, C. C. Ho, R. H. Ottewill, Brit. Polym., J.5, 347 (1973).

    Google Scholar 

  9. Chung-Li, Y., J. W. Goodwin, R. H. Ottewill, Prog. Coll. Polym. Sci.60, 163, 1976.

    Google Scholar 

  10. Homola, A. M., M. Inoue, A. A. Robertson, J. Appl. Polym. Sci.19, 3077 (1975).

    Google Scholar 

  11. Cricks, R., Personal Communication, I. C.I. Plastics Division, Welwyn Garden City, Herts.

  12. Lips, A., Disc. Farad. Soc.65, 326 (1978).

    Google Scholar 

  13. Cornell, R. M., J. W. Goodwin, R. H. Ottewill, J. Coll. Inter. Sci.71, 254 (1979).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Walsh, D.J., Anderson, J., Parker, A. et al. A flow ultramicroscope for particle counting and size distribution analysis. Colloid & Polymer Sci 259, 1003–1009 (1981). https://doi.org/10.1007/BF01558614

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01558614

Key words

Navigation