Abstract

Determination of ovarian follicular size and number by real-time ultrasound lacks the precision that has been ascribed to it. Four major error sources inherent in the scanning and interpreting process were analyzed to determine the relative contributions to overall variation. The sources measured were machine, sonographer, sonologist, and patient bladder volume. A protocol using a normal clomiphene-stimulated woman allowed the determination of the coefficient of variance for both follicular number and follicular diameter as well as a mean diameter range in each of the categories. A large degree of variation was found in all groups. Surprisingly, it was noted that maximal bladder filling did not produce optimal images. We believe that while variability in ultrasound can be recognized and lessened, it cannot be eliminated. Thus, caution must be used when ultrasound follicular comparisons are made within each program from day to day and particularly between institutions. A liberal range should be allowed for optimal follicle sizes for any given stimulation protocol.

This is a preview of subscription content, log in to check access.

References

  1. 1.

    Vargyas JM, Marrs RP, Kletzky OA, Mishell DR: Correlation of ultrasonic measurement of ovarian follicle size and serum estradiol levels in ovulatory patients following clomiphene citrate for in vitro fertilization. Am J Obstet Gynecol 1982;144:569–573

  2. 2.

    Jones G: The use of human menopausal gonadotropin for ovulation stimulation in patients for in vitro fertilization. Infertility 1983;6:11–29

  3. 3.

    Marrs RP, Vargyas JM, March CM: Correlation of ultrasonic and endocrinologic measurements in human menopausal gonadotropin therapy. Am J Obstet Gynecol 1983;145:417–421

  4. 4.

    Ylostalo P, Ronnberg L, Jouppila, P: Measurement of the ovarian follicle by ultrasound in ovulation induction. Fertil Steril 1979;31:651–655

  5. 5.

    Queen JT, O'Brien GD, Bains LM, Simpson J, Collins WP, Campbell S: Ultrasound scanning of ovaries to detect ovulation in women. Fertil Steril 1980;34:99–105

  6. 6.

    Seibel MM, McArdel CR, Thompson IE, Berger MJ, Taymor ML: The role of ultrasound in ovulation induction: A critical appraisal. Fertil Steril 1981;36:573–577

  7. 7.

    Buttery B, Trounson A, McMaster R, Wood C: Evaluation of diagnostic ultrasound as a parameter of follicular development in an in vitro fertilization program. Fertil Steril 1983;39:458–463

Download references

Author information

Correspondence to Gail S. Prins.

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Prins, G.S., Vogelzang, R.L. Inherent sources of ultrasound variability in relation to follicular measurements. J Assist Reprod Genet 1, 221–225 (1984). https://doi.org/10.1007/BF01131620

Download citation

Key Words

  • in vitro fertilization (IVF)
  • ultrasound
  • ovarian follicles