European Journal of Nuclear Medicine

, Volume 16, Issue 8–10, pp 639–641 | Cite as

Two lymphoscintigraphic agents compared in vitro and in vivo in rabbit knees

  • Steen Levin Nielsen
  • Bente Pedersen
  • Eiliv Svalastoga
  • Dimitrios Vittas
  • Inge Reiman
Original Article

Abstract

Two99mTc-labelled colloidal radiopharmaceuticals [99mTc-albumin colloid (A) and99mTc-rhenium sulfide colloid (B)] were compared in vitro in saline, plasma, and synovial fluid with regard to particle size, radiochemical purity, protein binding level, and stability at varying acidity. The purpose was to compare the two compounds in studies of lymphatic drainage from the knee joint of rabbits.

Particle size for A was uniform at about 10 nm, but for B it varied between 40 and 80 nm. The radiochemical purity was lowest for B (90%–95%), with a small fraction of minor particles. B was protein bound, which was only the case for A in joint fluid from synovitic knees.

A faster disappearance of A than B was observed from the knee joint, with lesser retention in the regional lymph nodes. A negligible uptake of colloid was seen in the liver. The major fraction of radioactivity absorbed from the knee was excreted in the urine. The differences between in vitro and in vivo stability are probably due to phagocytosis in the synovial membrane.

Key words

Albumin colloid Lymphoscintigraphy Rabbit knee Synovial fluid Sulfide colloid 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Bergquist L, Strand S-E, Hafström L, Musson P-E (1984) Lymphoscintigraphy in patients with malignant melanoma: a quantitative and qualitative evaluation of its usefullness. Eur J Nucl Med 9:129–135Google Scholar
  2. Kaplan WD, Davis MA, Rose CM (1979) Radiopharmaceuticals for lymphoscintigraphy. J Nucl Med 20:933–937Google Scholar
  3. Nagai K, Ito Y, Nobuaki O, Muranaka A (1982) Deposition of small99mTc-labelled colloids in bone marrow and lymph nodes. Eur J Nucl Med 7:66–70Google Scholar
  4. Pedersen B, Kristensen K (1981) Evaluation of methods for sizing of colloidal radiopharmaceuticals. Eur J Nucl Med 6:521–526Google Scholar
  5. Reimann I, Vittas D, Nielsen SL, Svalastoga E (1987) Intraarticular lymphoscintigraphy of the normal knee joint in rabbits. Med Sci Res 15:909–910Google Scholar
  6. Strand S-E, Persson BRR (1979) Quantitative Iymphoscintigraphy I: basic concepts for optimal uptake of radiocolloids in the parasternal lymph nodes of rabbits. J Nucl Med 20:1038–1046Google Scholar
  7. Vittas D, Reimann I, Nielsen SL, (1987) Intraarticular lymphoscintigraphy of the human knee joint. Lymphology 20:98–101Google Scholar

Copyright information

© Springer-Verlag 1990

Authors and Affiliations

  • Steen Levin Nielsen
    • 1
  • Bente Pedersen
    • 3
  • Eiliv Svalastoga
    • 4
  • Dimitrios Vittas
    • 2
  • Inge Reiman
    • 2
  1. 1.Department of Nuclear MedicineDenmark
  2. 2.Department of Orthopedic SurgeryHerlev HospitalDenmark
  3. 3.Isotope Pharmacy, National Board of HealthDenmark
  4. 4.Department of Small Animal Diseases Royal Veterinary and Agricultural UniversityCopenhagenDenmark

Personalised recommendations