Journal of Medical Systems

, Volume 6, Issue 6, pp 539–554

Dynamic volume imaging of moving organs

  • R. A. Robb
  • L. J. Sinak
  • E. A. Hoffman
  • J. H. Kinsey
  • L. D. Harris
  • E. L. Ritman
Article

Abstract

The Dynamic Spatial Reconstructor system has been developed to dynamically (up to 60/sec) image the entire 3-D volume (up to 240 adjacent 1-mm-thick transverse sections) encompassing moving organs of the body, particularly the heart and lungs, or the circulation in any organ. This capability permits accurate regional and global measurements to be made of the important relationships between structure and function within and among these organs, which in turn facilitates achievement of new insights into the basic physiological processes of these organs, and promises increased sensitivity and specificity in the diagnosis of pathology that affects normal organ function. This article explains the biomedical and technological rationale for development of the DSR, describes the design concepts and practical operation of the system, and presents preliminary results obtained with the system, including initial data from one of the first patient studies.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Symposium on Biological Effects, Imaging Techniques, and Dosimetry of Ionizing Radiations. Department of Health and Human Sciences, Publication (FDA), 80-8126 (July) 1980.Google Scholar
  2. 2.
    Cormack A.M., Early two-dimensional reconstruction (CT scanning) and recent topics stemming from it. Nobel Lecture, December 8, 1979.J. Comput. Assist. Tomogr. 4(5):658–664, 1980.Google Scholar
  3. 3.
    Hounsfield, G.N., Computed medical imaging. Nobel Lecture, December 8, 1979.J. Comput. Assist. Tomogr. 4(5):665–674, 1980.Google Scholar
  4. 4.
    Gordon, R., and Herman, G.T., Three-dimensional reconstruction from projections: A review of algorithms.Int. Rev. Cytol. 38:111–151, 1974.Google Scholar
  5. 5.
    Shepp, L.A., and Kruskal, J.B., Computerized tomography: The new medical x-ray technology.Am. Math. Monthly. 85(6):420–439, 1978.Google Scholar
  6. 6.
    Dwyer, S.J., III, Brenner, D.J., Takasugi, S., and Goldberg, H., Annotated bibliography of computed tomography. Special Publication Series UMC-HCTC/E-001, University of Missouri-Columbia, 1979.Google Scholar
  7. 7.
    Ring, B.A., An overview: Computed axial tomography.Appl. Radiol. November-December: 110–125, 1979.Google Scholar
  8. 8.
    Alfidi, R.J., MacIntyre, W.J., and Haaga, J.R., The effects of biological motion on CT resolution.Am. J. Roentgenol. 127:11–15, 1976.Google Scholar
  9. 9.
    Hounsfield, G.N., Picture quality of computed tomography.Am. J. Roentgenol. 127:3–9, 1976.Google Scholar
  10. 10.
    Glover, G.H., and Eisner, R.L., Theoretical resolution of computed tomography systems.J. Comput. Assist. Tomogr. 3(1):85–91, 1979.Google Scholar
  11. 11.
    Huesman, R.H., The effects of a finite number of projection angles and finite lateral sampling of projections on the propagation of statistical errors in transverse section reconstruction.Phys. Med. Biol. 22:511–521, 1977.Google Scholar
  12. 12.
    Frieder, G., and Herman, G.T., Resolution in reconstructing objects from electron micrographs.J. Theoret. Biol. 33:189–211, 1971.Google Scholar
  13. 13.
    Chesler, D.A., Riederer, S.J., and Pelc, N.J., Noise due to photon counting statistics in computed x-ray tomography.J. Comput. Assist. Tomogr. 1(1):64–74, 1977.Google Scholar
  14. 14.
    Brooks, R.A., and DiChiro, G., Slice geometry in computer assisted tomography.J. Comput. Assist. Tomogr. 1(2):191–199, 1977.Google Scholar
  15. 15.
    Johnson, S.A., Total body exposure, pixel size, and signal-to-noise ratio considerations for three-dimensional x-ray attenuation reconstructions.Reconstruction Tomography in Diagnostic Radiology and Nuclear Medicine (M.M. Ter-Pogossian, M.E. Phelps, G.L. Brownell, J.R. Cox, Jr., D.O. Davis, and R.G. Evens, eds.), University Park Press, Baltimore, 1977, pp. 199–214.Google Scholar
  16. 16.
    Shepp, L.A., and Stein, J.A., Simulated reconstruction artifacts in computerized x-ray tomography.Reconstruction Tomography in Diagnostic Radiology and Nuclear Medicine (M.M. Ter-Pogossian, M.E. Phelps, G.L. Brownell, J.R. Cox, Jr., D.O. Davis, and R.G. Evens, eds.), University Park Press, Baltimore, 1977, pp. 33–48.Google Scholar
  17. 17.
    Robb, R.A., and Ritman, E.L., High-speed synchronous volume computed tomography of the heart.Radiology 133:655–661, 1979.Google Scholar
  18. 18.
    Ritman, E.L., Robb, R.A., Johnson, S.A., Chevalier, P.A., Gilbert, B.K., Greenleaf, J.F., Sturm, R.E., and Wood, E.H., Quantitative imaging of the structure and function of the heart, lungs, and circulation.Mayo Clin. Proc. 53:3–11, 1978.Google Scholar
  19. 19.
    Guthaner, D.F., Wexler, L., and Harell, G., Computed tomography demonstration of cardiac structures.Am. J. Roentgenol. 133(1):75–81, 1979.Google Scholar
  20. 20.
    McLoud, T.C., Wittenberg, J., and Ferrucci, Jr., J.T., Computed tomography of the thorax and standard radiographic evaluation of the chest: A comparative study.J. Comput. Assist. Tomogr. 3(2):170–180, 1979.Google Scholar
  21. 21.
    Gur, D., Drayer, B.P., Borovetz, H.S., Griffith, B.P., Hardesty, R.L., and Wolfson, S.K., Dynamic computed tomography of the lung: Regional ventilation measurements.J. Comput. Assist. Tomogr. 3(6):749–753, 1979.Google Scholar
  22. 22.
    Sagal, S.S., Weiss, E.S., Gillard, R.G., Hounsfield, G.N., Gilbert, R., Jost, T., Stanley, R.J., and Ter-Pogossian, M.M., Gated computed tomography of the human heart.Invest. Radiol. 12(6):563–566, 1977.Google Scholar
  23. 23.
    Harrell, G.S., Guthaner, D.F., Breiman, R.S., Morehouse, C.C., Seppi, D.J., Marshall, W.H., and Wexler, L., Stop-action cardiac computed tomography.Radiology 123(2):515–517, 1977.Google Scholar
  24. 24.
    Beringer, W., Redington, R., Leuc, W., Axel, L., Norman, D., Brundage, B., Carlsson, E., Herfkens, R., and Lipton, M., Technical aspects and clinical applications of CT/X, a dynamic CT scanner.J. Comput. Assist. Tomogr. 5(2):206–215, 1981.Google Scholar
  25. 25.
    Boyd, D.P., Gould, R.G., Quinn, J.K., Sparks, R., Stanley, J.H., and Herrmannsfeldt, W.B., A proposed dynamic cardiac 3-D densitometer for early detection and evaluation of heart disease.IEEE Trans. Nucl. Sci. NS-26(2):2724–2727, 1979.Google Scholar
  26. 26.
    Robb, R.A., Ritman, E.L., Gilbert, B.K., Kinsey, J.H., Harris, L.D., and Wood E.H., The DSR: A high-speed three-dimensional x-ray computed tomography system for dynamic spatial reconstructions of the heart and circulation.IEEE Trans. Nucl. Sci. NS-26(2):2713–2717, 1979.Google Scholar
  27. 27.
    Ritman, E.L., Kinsey, J.H., Robb, R.A., Gilbert, B.K., Harris, L.D., and Wood, E.H., Three-dimensional imaging of heart, lungs, and circulation.Science 210:273–280, 1980.Google Scholar
  28. 28.
    Iinuma, T.A., Tateno, Y., Umegaki, Y., and Watanabe, E., Proposed system for ultra-fast computed tomography.J. Comput. Assist. Tomogr. 4:494–499, 1977.Google Scholar
  29. 29.
    Haimson, J., X-ray source without moving parts for ultra-high-speed tomography.IEEE Trans. Nucl. Sci. NS-26(2):2857–2861, 1979.Google Scholar
  30. 30.
    Robb, R.A., and Gilbert, B.K., Description and evaluation of a system for high-speed three-dimensional computed tomography of the body. The Dynamic Spatial Reconstructor.NCC-80 National Computer Conference, American Federation of Information Processing Society 49:427–436, 1980.Google Scholar
  31. 31.
    Kinsey, J.H., Robb, R.A., Ritman, E.L., and Wood, E.H., The DSR—A high temporal resolution volumetric roentgenographic CT scanner.Herz 5(3):177–188, 1980.Google Scholar
  32. 32.
    Robb, R.A., X-ray computed tomography: An engineering synthesis of multi-scientific principles.CRC Critical Rev. Bioeng. 7(4):265–333, 1982.Google Scholar
  33. 33.
    Herman, G.T., Lakshminarayanan, A.V., Naparstek, A., Ritman, E.L., Robb, R.A., and Wood, E.H., Rapid computerized tomography.Medical Data Processing (M. Laudet, J. Anderson, and S. Begon, eds.), Taylor and Francis, London, 1976, pp. 581–598.Google Scholar
  34. 34.
    Artzy, E., Frieder, G., Herman, G.T., and Liu, H.K., A system for three-dimensional dynamic display of organs from computed tomograms.Proc. Comput. Appl. Radiol. Comput. Assist. Anal. Radiol. Images, 1979, pp. 285–290.Google Scholar

Copyright information

© Plenum Publishing Corporation 1982

Authors and Affiliations

  • R. A. Robb
    • 1
  • L. J. Sinak
    • 1
  • E. A. Hoffman
    • 1
  • J. H. Kinsey
    • 1
  • L. D. Harris
    • 1
  • E. L. Ritman
    • 1
  1. 1.From the Biodynamics Research Unit, Department of Physiology and BiophysicsMayo FoundationRochester

Personalised recommendations