Abstract
We imaged two patients who had silicone oil injected into their vitreous cavities. The images demonstrated an increased chemical shift artifact. We developed and tested an in vitro silicone oil model in an attempt to explain this. To our knowledge, this artifact has not been previously described. We constructed a phantom using medication cups containing water, lard and two types of silicone. Background control baths of water and lard were used to simulate different local environments. The phantoms were imaged with T1- and T2-weighted and T1-weighted fat suppression sequences. The artifacts were due to the pronounced chemical shift of silicone in relation to intraconal fat. Our model accurately reproduced our clinical images. Spectral analysis of the silicone model revealed different resonating frequencies for fat/silicone, thereby explaining the pronouced chemical shift artifact.
Key words
Orbit Silicone MRI Chemical shiftPreview
Unable to display preview. Download preview PDF.
References
- 1.Cibis PA, Becker B, Okun E, Canaan S (1962) The use of liquid silicone in retinal detachment surgery. Arch Ophthalmol 68: 590–599Google Scholar
- 2.Armaly MF (1962) Ocular tolerance to silicone. Arch Ophthalmol 68: 126–131Google Scholar
- 3.Machemer R (1971) Vitrectomy: a pars plana approach. Trans Am Acad Ophthalmol Otolaryng 75: 813–820Google Scholar
- 4.Scott JD (1989) Silicone oil as an instrument. In: Glaser BM, Michels RG (eds) Retina — surgical retina, vol 3. CV Mosby, Baltimore, pp 307–315Google Scholar
- 5.Steinbach BG, Hiskes SK, Fitzsimmons JR, Lanier L (1992) Phantom evaluation of imaging modalities for silicone breast implants. Invest Radiol 27: 841–846Google Scholar
- 6.Gorczya DP, Sinha S, Ahn CY et al (1992) Silicone breasts implants in vivo: MR imaging. Radiology 185: 407–410Google Scholar
- 7.Okun E, Arribas N, Johnston GP (1969) Therapy of retinal detachment complicated by massive preretinal fibroplasia. Mod Probl Ophthalmol 8: 563–571Google Scholar
- 8.Leaber PK (1989) Complications of intraocular silicone oil. In: Glaser BM, Michels RG (eds) Retina — surgical retina, vol 3. CV Mosby, Baltimore, pp 293–306Google Scholar
- 9.Willott MR (1988) NMR chemical principles. In: Partain CL, Price RR, Patton JA, Julkarni MV, James Jr. AE (eds) Magnetic resonance imaging, 2nd edn: Physical principles and instrumentation, vol 2. Saunders, Philadelphia, pp 987–1002Google Scholar
- 10.Smith AS, Weinstein MA, Hurst GC et al (1990) Intracranial chemical-shift artifacts on MRI images of the brain: observations and relation to sampling bandwidth. AJR 154: 1275–1283Google Scholar
- 11.Smith RC, Lange RC, McCarthy SM (1991) Chemical shift artifact: dependence on shape and orientation of lipid-water interface. Radiology 181: 225–229Google Scholar
- 12.Schneider E, Chan TW (1993) Selective MR imaging of silicone with the three-point Dixon technique. Radiology 187: 89–93Google Scholar