Summary
Both diastolic and systolic arterial blood pressure can be measured with reasonable accuracy in the intact unanaesthetized rat by an improved tail-cuff method, which is described. In 12 rats the results of the indirect technique were compared with simultaneous recordings of intraaortic blood pressure. From this comparison correlation coefficients were calculated, which were 0.944 for the diastolic and 0.963 for the systolic readings.
Literatur
Breuninger, H.: Methode zur unblutigen Messung des Blutdrucks an Kleintieren. Arzneimittel-Forsch.6, 222–225 (1956).
Byrom, F. B., Wilson, C.: A plethysmographic method for measuring systolic blood pressure in the intact rat. J. Physiol. (Lond.)93, 301–304 (1938).
Frangipane, G., Aporti, F.: Improved indirect method for the measurement of systolic blood pressure in the rat. J. Lab. clin. Med.73, 872–876 (1969).
Geddes, L. A.: The direct and indirect measurement of blood pressure. Chicago: Year Book Med. Publ. 1970.
Gerold, M., Fünfschilling, H.: Abhängigkeit der indirekten Blutdruckmessung an Ratten von der Größe der Kompressionsmanschette. Arzneimittel-Forsch.21, 2071–2074 (1971).
Hager, H.: Die Ophthalmodynamographie als Methode zur Beurteilung des Gehirnkreislaufes. Klin. Mbl. Augenheilk.142, 827–846 (1963).
Kaindl, F., Polzer, K., Schuhfried, F.: Rheographie. Darmstadt: Th. Steinkopff 1967.
Luckner, H., Müller, F., Zieger, G.: Ein plethysmographisches Verfahren zur Bestimmung des systolischen und diastolischen Blutdrucks an unnarkotisierten Ratten. Pflügers Arch. ges. Physiol.258, 343–357 (1954).
Maistrello, I., Mascher, R.: Measurement of systolic blood pressure of rats: comparison of intraarterial and cuff values. J. appl. Physiol.26, 188–193 (1969).
Nyboer, J.: Electrical Impedance Plethysmography, 2. Aufl. Springfield, Ill.: Ch. C. Thomas 1970.
Pauschinger, P., Barbey, K., Brecht, K.: Über die hämodynamischen Grundlagen der auskultatorischen und graphischen Kriterien bei der Blutdruckmessung nach Riva-Rocci-Korotkow. Klin. Wschr.36, 915–924 (1958).
Pfeffer, J. M., Pfeffer, M. A., Frohlich, E. D.: Validity of an indirect tail-cuff method for determining systolic arterial pressure in unanesthetized normotensive and spontaneously hypertensive rats. J. Lab. clin. Med.78, 957–962 (1971).
Recklinghausen, H. von: Blutdruckmessung und Kreislauf in den Arterien des Menschen. Leipzig: Th. Steinkopff 1940.
Rowberg, A., Franklin, D., van Citters, R. L.: Nontraumatic method for measurement of blood pressure in animals with tails. J. appl. Physiol.27, 301–302 (1969).
Skeggs, L. T., Leonards, J. R.: A new endpoint for blood pressure determination in the rat's tail. Proc. Soc. exp. Biol. (N.Y.)63, 294–296 (1946).
Swales, J. D., Tange, J. D.: A photoelectric method of blood pressure measurement in the rat. J. Lab. clin. Med.75, 879–885 (1970).
Wetterer, E., Kenner, Th.: Grundlagen der Dynamik des Arterienpulses. Berlin-Heidelberg-New York: Springer 1968.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Hampel, H., Siebe, H. & Thron, H.L. Ein Verfahren zur unblutigen Bestimmung von diastolischem und systolischem Blutdruck bei der unnarkotisierten Ratte. Pflugers Arch. 340, 263–272 (1973). https://doi.org/10.1007/BF00586843
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00586843