Springer Nature is making SARS-CoV-2 and COVID-19 research free. View research | View latest news | Sign up for updates

Potassium in the rat kidney proximal tubules in situ: Determination by K+-selective liquid ion-exchange microelectrodes

  • 31 Accesses

  • 19 Citations

Summary

Intraluminal K+ concentration in the rat kidney proximal tubule was measured in situ by means of K+-selective liquid ion-exchange microelectrodes. By virtue of its independence of sampling techniques, the in situ measurement is more accurate in dealing with fluids flowing through microtubular structures. Using K+-selective liquid ion-exchange microelectrodes it was observed that the K+ concentration falls along the length of the proximal convoluted tubule. The mean (TF/P) K concentration ratio of 0.89±0.01 for the first convolution is significantly greater (p<0.001) than the mean ratio of 0.81±0.01 for the last convolution of the proximal tubule. A description is given of the construction and calibration of the K+-selective microelectrode with a new liquid ion-exchanger.

This is a preview of subscription content, log in to check access.

References

  1. 1.

    Bloomer, H. A., Rector, F. C., Jr., Seldin, D. W.: The mechanism of potassium reabsorption in the proximal tubule of the rat. J. clin. Invest.42, 277 (1963).

  2. 2.

    Khuri, R. N., Flanigan, W. J., Oken, D. E.: Potassium in proximal tubule fluid of rats and necturus measured with glass electrodes. J. appl. Physiol.21, 1568 (1966).

  3. 3.

    —, Goldstein, D. A., Maude, D. L., Edmonds, C., Solomon, A. K.: Single proximal tubules of the necturus kidney: Na and K determination by glass electrodes. Amer. J. Physiol.204, 743 (1963).

  4. 4.

    Litchfield, J. B., Bott, P. A.: Micropuncture study of renal excretion of water, K, Na, and Cl in the rat. Amer. J. Physiol.203, 667 (1962).

  5. 5.

    Malnic, G., Klose, R. M., Giebisch, G.: Micropuncture study of renal potassium excretion in the rat. Amer. J. Physiol.206, 674 (1964).

  6. 6.

    Marsh, D. G., Ullrich, K. J., Rumrich, G.: Micropuncture analysis of the behavior of potassium ions in rat renal cortical tubules. Arch. ges. Physiol.277, 107, (1963).

  7. 7.

    Settzo, R. J., Wise, W. M.: Liquid organic ion-exchanger electrode with organophilic-hydrophobic membrane. U.S. Patent No. 3,448,032 (1969).

  8. 8.

    Wise, W. M., Kurey, M. J., Baum, G.: Direct potentiometric measurement of potassium in blood serum with liquid ion-exchange electrode. Clin. Chem.16, 103 (1970).

Download references

Author information

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Khuri, R.N., Agulian, S.K. & Wise, W.M. Potassium in the rat kidney proximal tubules in situ: Determination by K+-selective liquid ion-exchange microelectrodes. Pflugers Arch. 322, 39–46 (1971). https://doi.org/10.1007/BF00586663

Download citation

Key-Words

  • Potassium Microelectrode
  • Liquid Ion-Exchange Microelectrode
  • Proximal Tubule Potassium

Schlüsselwörter

  • Kalium-Mikroelektrode
  • Flüssigkeits-Ionenaustausch-Mikroelektrode
  • Kalium in proximalen Tubuli