Advertisement

On-line monitoring of benzene air concentrations while driving in traffic by means of isotopic dilution gas chromatography/mass spectrometry

  • E. Davoli
  • L. Cappellini
  • M. Moggi
  • S. Ferrari
  • R. Fanelli
Original Article

Abstract

There is no shortage of information about the average benzene concentrations in urban air, but there is very little about microenvironmental exposure, such as in-vehicle concentrations while driving in various traffic conditions, while refuelling, or while in a parking garage. The main reason for this lack of data is that no analytical instrumentation has been available to measure on-line trace amounts of benzene in such situations. We have recently proposed a highly accurate, high-speed cryofocusing gas chromatography/mass spectrometry (GC/MS) system for monitoring benzene concentrations in air. Accuracy of the analytical data is achieved by enrichment of the air sample before trapping, with a stable isotope permeation tube system. The same principles have been applied to a new instrument, specifically designed for operation on an electric vehicle (Ducato Elettra, Fiat). The zero emission vehicle and the fully transportable, battery-operated GC/MS system provide a unique possibility of monitoring benzene exposure in real everyday situations such as while driving, refuelling, or repairing a car. All power consumptions have been reduced so as to achieve a battery-operated GC/MS system. Liquid nitrogen cryofocusing has been replaced by a packed, inductively heated, graphitized charcoal microtrap. The instrument has been mounted on shock absorbers and installed in the van. The whole system has been tested in both fixed and mobile conditions. The maximum monitoring period without external power supply is 6 h. The full analytical cycle is 4 min, allowing close to real-time monitoring, and the minimum detectable level is 1 μg/m3 for benzene. In-vehicle monitoring showed that, when recirculation was off and ventilation on, i.e., air from outside the vehicle was blown inside, concentrations varied widely in different driving conditions: moving from a parking lot into normal traffic on an urban traffic condition roadway yielded an increase in benzene concentration from 17 to 62.3 μg/m3 even if the actual distance was small. A larger increase was observed when a car was left with the engine running at a distance 2 m from the zero emission vehicle: We measured an increment of benzene concentrations from 15.2 to 174.4 μg/m3 with a car equipped with a catalytic converter, and from 19.1 to 386.3 μg/m3 with a car without such a converter.

Key words

Gas chromatography Mass spectrometry Benzene Air pollution 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Air quality standards: benzene (1994) HMSO, LondonGoogle Scholar
  2. 2.
    Brunnemann KD, Kagan MR, Cox JE, Hoffmann D (1990) Analysis of 1,3-butadiene and other selected gas-phase components in cigarette mainstream and sidestream smoke by gas chromatography-mass selective detection. Carcinogenesis 11:1863–1868PubMedGoogle Scholar
  3. 3.
    Chan CC, Ozkaynak H, Spengler JD, Sheldon L (1991) Driver exposure to volatile organic compounds, CO, ozone and NO2 under different driving conditions. Environ Sci Technol 25:964–972Google Scholar
  4. 4.
    Davoli E, Cappellini L, Moggi M, Fanelli R (1994) Automated high-speed analysis of selected organic compounds in urban air by on-line isotopic dilution cryofocusing gas chromatography/mass spectrometry. J Am Soc Mass Spectrometry 5:1001–1007CrossRefGoogle Scholar
  5. 5.
    Davoli E, Leone A, Stramare L, Fanelli R (1995) Campionamento e determinazione di idrocarburi volatili in aria: l'impiego della spettrometria di massa con diluizione con isotopi stabili come possible metodo di riferimento. In: Minoia C, Apostoli P, Bartolucci GB (eds) II benzene: tossicologia, ambienti di vita e di lavoro. Morgan Edizioni Techniche, Milan, pp 283–289Google Scholar
  6. 6.
    Davoli E, Passagrilli C, Stramare L, Fanelli R (1994) Sampling and determination of VOC in environmental air: stable isotope dilution mass spectrometry as a candidate reference method. Proceedings of the 42nd ASMS Conference on mass spectrometry and allied topics. Chicago, 29 May–3 June 1994Google Scholar
  7. 7.
    Davoli E, Rossi O, Fanelli R (1993) A candidate reference method for automated analysis of selected organic compounds in urban air. In: Ciccioli P (ed) Atti 1° Simposio Nazionale sulle Strategie e Tecniche di Monitoraggio dell'Atmosfera, Rome, 20–22 September 1993. Società Chimica Italiana, Rome, pp 447–456Google Scholar
  8. 8.
    Davoli E, Rossi O, Fanelli R (1993) Stable isotope permeation tubes for GC-MS analysis of VOC in air. J High Res Chromatogr 16:626–628Google Scholar
  9. 9.
    Decreto Ministeriale 25 Novembre 1994. Aggiornamento delle norme tecniche in materia di limiti di concentrazione e di livelli di attenzione e di allarme per gli inquinanti atmosferici nelle aree urbane c disposizioni per la misura di alcuni inquinanti di cui al DM del 14 aprile 1994. Ministro dell'Ambiente e Ministero della Sanità, RomeGoogle Scholar
  10. 10.
    Foà V (1994) Per il benzene è allarme rosso. Impresa Ambiente 8:6–10Google Scholar
  11. 11.
    Lioy PJ (1990) Assessing total human exposure to contaminants. Environ Sci Technol 24:938–945Google Scholar
  12. 12.
    Russell M, Gruber M (1987) Risk assessment in environmental policy-making. Science 236:286–290PubMedGoogle Scholar
  13. 13.
    Seinfeld JH (1989) Urban air pollution: state of the science. Science 243:745–752Google Scholar
  14. 14.
    U.S. Environmental Protection Agency (1992) Motor vehicle-related air toxics study. Public Review Draft, December 1992Google Scholar
  15. 15.
    Wallace LA (1989) The exposure of the general population to benzene. Cell Biol Toxicol 5:297–314PubMedGoogle Scholar
  16. 16.
    World Health Organization (1987) IARC monographs on the evaluation of carcinogenic risks to humans, supplement 7: overall evaluations of carcinogenicity: an updating of IARC monographs volumes 1 to 42. IARC, LyonGoogle Scholar

Copyright information

© Springer-Verlag 1996

Authors and Affiliations

  • E. Davoli
    • 1
  • L. Cappellini
    • 1
  • M. Moggi
    • 1
  • S. Ferrari
    • 2
  • R. Fanelli
    • 1
  1. 1.Istituto di Ricerche Farmacologiche Mario NegriMilanoItaly
  2. 2.RIAL Vacuum S.p.A.ParmaItaly

Personalised recommendations