Comparison of the measurements of the cerebral ventricles obtained by CT scanning and pneumoencephalography

  • Originals
  • Published:
Neuroradiology Aims and scope Submit manuscript

Summary

This study was undertaken to compare the accuracy of measurements of the ventricular system obtained by the CT scanner and pneumoencephalography (PEG). In it the ventricular system was evaluated in each case by measuring the span of the frontal horns, cellae mediae and third ventricle in relation to the diameter of the inner and outer tables of the skull from the PEG films. The indices of Evans, Schiersmann, and Schaltenbrand and Nürnberger were applied to these measurements. The same indices were obtained using the appropriate CT printouts. A very good measure of agreement was obtained with the indices arrived at from both the CT scan printouts and the pneumoencephalograms.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Dandy, W.E.: Ventriculography following the injection of air into the cerebral ventricles. Ann. Surg. 68, 5–11 (1918)

    Google Scholar 

  2. Dandy, W.E.: Roentgenography of the brain after the injection of air into the spinal canal. Ann. Surg. 70, 397–403 (1919)

    Google Scholar 

  3. Evans, W.A.: An encephalographic ratio for estimating ventricular enlargement and cerebral atrophy. Arch. Neurol. Psychiatr. 47, 931–937 (1942)

    Google Scholar 

  4. Gawler, J., du Boulay, G.H., Bull, J.W.D., Marshall, J.: Computerized tomography (The EMI scanner): A comparison with pneumoencephalography and ventriculography. J. Neurol. Neurosurg. Psychiatr. 39, 203–211 (1976)

    Google Scholar 

  5. Gyldenstedt, C., Kosteljanetz, M.: Measurement of the normal ventricular system with computer tomography of the brain. Neuroradiology 10, 205–213 (1976)

    Google Scholar 

  6. Hanson, J., Levander, B., Liliequist, B.: Size of the intracerebral ventricles as measured with computer tomography, encephalography and echoventriculography. Acta Radiol. [Suppl.] (Stockh.) 346, 98–106 (1975)

    Google Scholar 

  7. Hounsfield, G.N.: Computerized transverse axial scanning (tomography): Part 1. Description of system. Br. J. Radiol. 46, 1016–1022 (1973)

    Google Scholar 

  8. Schaltenbrand, G., Nürnberger, S.: Radiographic landmarks for stereotactic operations. In: Introduction to sterotaxis with an atlas of the human brain Vol. 1. pp. 421–436. (eds. G. Schaltenbrand and P. Bailey) New York: Grune and Stratton 1959

    Google Scholar 

  9. Schiersmann, O.: Einführung in die Encephalographie. Stuttgart: Thieme 1952

    Google Scholar 

  10. Synek, V., Reuben, J.R.: The ventricular-brain ratio using planimetric measurement of EMI scans. Br. J. Radiol. 49, 233–237 (1976)

    Google Scholar 

  11. Synek, V., Reuben, J.R., du Boulay, G.H.: Comparing Evans' index and computerized axial tomography in assessing relationship of ventricular size to brain size. Neurology 26, 231–233 (1976)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Synek, V., Reuben, J.R., Gawler, J. et al. Comparison of the measurements of the cerebral ventricles obtained by CT scanning and pneumoencephalography. Neuroradiology 17, 149–151 (1979). https://doi.org/10.1007/BF00339871

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00339871

Key words

Navigation