Advertisement

Polymer Bulletin

, Volume 28, Issue 4, pp 481–487 | Cite as

Thermal expansion of irradiated polyvinyl chloride from 10 K to 340 K

  • H. S. Jayanna
  • S. V. Subramanyam
Article

Summary

The coefficient of thermal expansion is measured for irradiated Polyvinyl Chloride (PVC) from 10K to 340K. The samples of PVC are irradiated, up to 500 Mrad in steps of 100 Mrad, in air at room temperature by using Co gamma rays with a dose rate of 0.3 Mrad/h. The PVC is an amorphous sample which is confirmed by X-ray diffraction. The coefficient of thermal expansion is found to decrease with radiation dose from 10K to 110K and it increaseswith radiation dose from 110K to 340K. The results are explained on the basis of radiation induced degradation of the sample.

Keywords

Radiation Polymer Chloride Thermal Expansion Radiation Dose 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Subrahmanyam H.N. and Subramanyam S.V., (1987) J. Polym. Sci. Polym. Phys., 25: 1549Google Scholar
  2. 2.
    Subrahmanyam H.N. and Subramanyam S.V., (1987) Polymer (GB) 20:1331Google Scholar
  3. 3.
    Lawton E.J., Bueche A.M. and Balwit J.S., (1953) Nature 172:76Google Scholar
  4. 4.
    Karpov V.L., (1855)Sessiya Akad. Nauk. SSSR Po. Mirnomu Ispolzovaniyu Atomnoi Energii, Moscow pp 1.Google Scholar
  5. 5.
    Charlesby A., (1953) Plastics 18: 142Google Scholar
  6. 6.
    Chapiro A. (1962) Radiation chemistry of polymeric systems Interscience, NY., pp 464.Google Scholar
  7. 7.
    Hiroshi Sobue, Yoneho Tabata and Yoshio Tajima (1958) J. Polym. Sci. 115: 598Google Scholar
  8. 8.
    Chapiro A. (1956) J. Chim. Physique, 53: 895Google Scholar
  9. 9.
    Charlesby A. (1960) Atomic radiation and polymers, Pergamon Press, Oxford, pp 312.Google Scholar
  10. 10.
    Miller A.A., (1958) J. Phy. Chem., 63:1755Google Scholar
  11. 11.
    Subrahmanyam H.N. and Subramanyam S.V., (1986) Framana 27:647Google Scholar
  12. 12.
    Krishnapur P.P., Subramanyam S.V. and Rajagopal E.S., (1979) Ind. J. Technol., 17: 165Google Scholar
  13. 13.
    Pott R. and Schefzyk, (1983) J. Phys. E., 16: 444Google Scholar
  14. 14.
    Subrahmanyam H.N., (1985) Ph.D., Thesis, Indian Institute of Science, Bangalore India.Google Scholar
  15. 15.
    Wang L.H., Choy C.L. and Porter R.S., J. Polym.Sci. (1982) Polym. Phys., 20:633Google Scholar
  16. 16.
    Wang L.H., Choy C.L. and Porter R.S., (1983) J.Polym.Sci. Polym.Phys., 21: 657Google Scholar
  17. 17.
    Hellwege K.H., Hennig J. and Knappe W., (1963) Kolloid-Z., 188: 121Google Scholar

Copyright information

© Springer-Verlag 1992

Authors and Affiliations

  • H. S. Jayanna
    • 1
  • S. V. Subramanyam
    • 1
  1. 1.Department of PhysicsIndian Institute of ScienceBangaloreIndia

Personalised recommendations