Respiratory compliance and resistance in mechanically ventilated patients with acute respiratory failure

  • M. Bernasconi
  • Y. Ploysongsang
  • S. B. Gottfried
  • J. Milic-Emili
  • A. Rossi
Original Articles

Abstract

The purpose of this study was noninvasive assessment of respiratory compliance and resistance in mechanically ventilated patients with acute respiratory failure (ARF). To this end, flow, change in lung volume, and airway pressure were measured at the proximal tip of the endotracheal tubes in twenty nine critically ill unselected patients. Eleven had acute exacerbation of chronic obstructive pulmonary disease (COPD), 8 had adult respiratory distress syndrome (ARDS) and 10 had ARF of various etiologies. Static compliance (Cst,rs), ‘intrinsic’ PEEP (PEEPi), as well as minimum and maximum resistance (Rrs,min and Rrs,max, respectively) were obtained with end-inspiratory and end-expiratory airway occlusions. We found that: (1) PEEPi was present in all patients with COPD (up to 11.4 cmH2O) and it was not uncommon in patients with ARF without history of chronic airway disease (up to 4.1 cmH2O). (2) Without correction for PEEPi average Cst,rs was not significantly different between ARDS and COPD patients, whereas the average corrected compliance was significantly lower in ARDS patients. (3) Substantial frequency-dependence of resistance was exhibited not only by COPD patients, but also by ARDS patients.

Key words

Acute respiratory failure Mechanical ventilation Respiratory resistance Static respiratory compliance Positive end-expiratory pressure (PEEP) Chronic obstructive pulmonary disease (COPD) Adult respiratory distress syndrome (ARDS) 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Agostoni E, Mead J (1964) Statics of the respiratory system. In: Fenn WO, Rahn H (eds) Handbook of Physiology. American Physiological Society, Sec. 3, Vol 1, Respiration, Washington, DC, p 387Google Scholar
  2. 2.
    Bates JHT, Rossi A, Milic-Emili J (1985) Analysis of the behaviour of the respiratory system with constant inspiratory flow. J Appl Physiol 58:1840CrossRefGoogle Scholar
  3. 3.
    Chung KF, Keyes SJ, Morgan BM, Jones PW, Snashall PD (1983) Mechanisms of airway narrowing in acute pulmonary oedema in dogs: influence of the vagus and lung volume. Clin Sci 65:289CrossRefGoogle Scholar
  4. 4.
    Cook CD, Mead J, Schreiner GL, Frank NR, Craig JM (1959) Pulmonary mechanics during induced pulmonary edema in anesthetized dogs. J Appl Physiol 14:177CrossRefGoogle Scholar
  5. 5.
    Don HF, Robson JC (1965) The mechanics of the respiratory system during anesthesia. The effect of atropine and carbon dioxide. Anesthesiology 26:168CrossRefGoogle Scholar
  6. 6.
    Esbensahde AM, Newman, JH, Lams PM, Jolles H, Brigham KL (1979) Respiratory failure after endotoxin infusion in sheep: Lung mechanics and lung fluid balance. J Appl Physiol 53:967CrossRefGoogle Scholar
  7. 7.
    Falke KJ, Pontoppidan H, Kumar A, Leith DE, Geffin B, Laver MB (1972) Ventilation with end-expiratory pressure in acute lung disease. J Clin Invest 51:2315CrossRefGoogle Scholar
  8. 8.
    Gattinoni L, Mascheroni D, Torresin A, Marcolin R, Fumagalli R, Vesconi S, Rossi GP, Rossi F, Baglioni S, Bassi F, Nastri G, Pesenti A (1986) Morphological response to positive end-expiratory pressure in acute respiratory failure. Computerized tomography study. Intensive Care Med 12:137CrossRefGoogle Scholar
  9. 9.
    Gottfried SB, Rossi A, Higgs BD, Calverley PMA, Zocchi L, Bozic C, Milic-Emili J (1985) Noninvasive determination of respiratory system mechanics during mechanical ventilation for acute respiratory failure. Am Rev Respir Dis 131:414PubMedGoogle Scholar
  10. 10.
    Gottfried SB, Rossi A, Milic-Emili J (1986) Dynamic hyperinflation, intrinsic PEEP, and the mechanically ventilated patient. Int Care Dig 5:30Google Scholar
  11. 11.
    Grimby G, Takishima T, Graham W, Macklem PT, Mead J (1968) Frequency-dependence of flow-resistance in patients with obstructive lung disease. J Clin Invest 47:1455CrossRefGoogle Scholar
  12. 12.
    Katz JA, Zinn SE, Ozenne GM, Fairley HB (1981) Pulmonary, chest wall and lung-thorax elastances in acute respiratory failure. Chest 80:304CrossRefGoogle Scholar
  13. 13.
    Kimball WR, Leith DE, Robins AG (1982) Dynamic hyperinflation and ventilator dependance in chronic obstructive pulmonary disease. Am Rev Respir Dis 126:991PubMedGoogle Scholar
  14. 14.
    Lavietes MH, Rochester DF (1981) Assessment of airway function during assisted ventilation. Lung 159:219CrossRefGoogle Scholar
  15. 15.
    Michel RP, Zocchi L, Rossi A, Cardinal GA, Ploysongsang Y, Poulsen RS, Milic-Emili J, Staub NC (1987) Does interstitial edema compress airways and arteries in the lungs? a morphometric study. J Appl Physiol 62:108CrossRefGoogle Scholar
  16. 16.
    Milic-Emili J (1986) Is weaning an art or a science? Am Rev Respir Dis 134:1107PubMedGoogle Scholar
  17. 17.
    Milic-Emili J, Gottfried SB, Rossi A (1987) Dynamic Hyperinflation: intrinsic PEEP and its ramifications in patients with respiratory failure. In: Vincent JL (ed) Update in intensive care and emergency medicine. Springer, Berlin Heidelberg New York, p 192Google Scholar
  18. 18.
    Montaner JSG, Tsang J, Evans KG, Mullen JBM, Burns AR, Walker DC, Wiggs B, Hogg JC (1986) Alveolar epithelial damage; a critical difference between high pressure and oleic-acid induced low pressure pulmonary edema. J Clin Invest 77:1786CrossRefGoogle Scholar
  19. 19.
    Otis AB, McKerrow CB, Bartlett RA, Mead J, McIlroy MB, Silverstone NJ, Radford EP (1956) Mechanical factors in distribution of pulmonary ventilation. J Appl Physiol 8:427CrossRefGoogle Scholar
  20. 20.
    Pepe PE, Marini JJ (1982) Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction. Am Rev Respir Dis 126:166PubMedGoogle Scholar
  21. 21.
    Ploysongsang Y, Zocchi L, Michel RP, Rossi A, Milic-Emili J, Staub NC (1985) Partitioning of respiratory mechanics in pulmonary interstitiate edema in dogs. Fed Proc 45:1910 (8756 abstract)Google Scholar
  22. 22.
    Rossi A, Gottfried SB, Higgs BD, Zocchi L, Grassino A, Milic-Emili J (1985) Respiratory mechanics in mechanically ventilated patients with respiratory failure. J Appl Physiol 58:1849CrossRefGoogle Scholar
  23. 23.
    Rossi A, Gottfried SB, Zocchi L, Higgs BD, Lennox S, Calverley PMA, Begin P, Grassino A, Milic-Emili J (1985) Measurement of static compliance of total respiratory system in patients with acute respiratory failure during mechanical ventilation. Am Rev Respir Dis 131:672PubMedGoogle Scholar
  24. 24.
    Simkovitz P, Brown K, Golberg P, Milic-Emili J, Gottfried SB (1987) Interaction between intrinsic and externally applied PEEP during mechanical ventilation. Am Rev Respir Dis 135:A202Google Scholar
  25. 25.
    Staub NC, Nagano H, Pearce ML (1967) Pulmonary edema in dogs, especially the sequence of fluid accumulation in lungs. J Appl Physiol 22:227CrossRefGoogle Scholar
  26. 26.
    Suter PM, Fairley HB, Isenberg MD (1975) Optimum end-expiratory airway pressure in patients with acute pulmonary failure. N Engl J Med 292:284CrossRefGoogle Scholar
  27. 27.
    Suter PM, Fairley HB, Isenberg MD (1978) Effect of tidal volume and positive end-expiratory pressure on compliance during mechanical ventilation. Chest 73:158CrossRefGoogle Scholar
  28. 28.
    Zin WA, Pengelly LD, Milic-Emili J (1982) Single-breath method for measurement of respiratory mechanics in anesthetized animals. J Appl Physiol 52:1266CrossRefGoogle Scholar

Copyright information

© Springer-Verlag 1988

Authors and Affiliations

  • M. Bernasconi
    • 2
  • Y. Ploysongsang
  • S. B. Gottfried
    • 1
  • J. Milic-Emili
    • 1
  • A. Rossi
    • 2
  1. 1.Meakins-Christie LaboratoriesMcGill UniversityMontrealCanada
  2. 2.Institute of Occupational MedicineUniversity of PaduaPaduaItaly

Personalised recommendations