Abstract
We report our preliminary experience with Spiral Z stents for transjugular intrahepatic portosystemic shunts (TIPS). The Spiral Z stent is a modification of the Gianturco-Rosch stent. TIPS was performed in 20 patients with symptomatic portal hypertension and was effective in 19 of them. One patient re-bled and died shortly after the procedure, despite of transjugular embolisation of gastro-oesophageal varices. The portal pressure decrease (5–16 mm Hg) was related to stent diameter (8–12 mm). Mean follow-up was 6 months. Our preliminary results confirm that the 12-mm Spiral Z stent is a suitable device for creation of effective TIPS.
Similar content being viewed by others
References
Rosch J, Hanafee WN, Snow H (1969) Transjugular portal venography and radiologic portacaval shunt: an experimental study. Radiology 92: 1112–1114
Colapinto RF, Stronell RD, Gildiner M, et al. (1983) Formation of intrahepatic portosystemic shunts using a ballon dilatation catheter: preliminary clinical experience. AJR 140: 709–714
Palmaz JC, Sibbitt RR, Reuter SR, Carcia F, Tio FO (1985) Expandable intrahepatic portacaval shunt stents: early experience in the dog. AJR 145: 821–825
Richter GM, Noeldge G, Palmaz JC, et al. (1990) Transjugular intrahepatic portacaval stent shunt: preliminary clinical results. Radiology 174: 1027–1030
Rosch J, Uchida BT, Putnam JS, Buschman RW, Law RD, Hershey AL (1987) Experimental intrahepatic portocaval anastomosis: use of expandable Gianturco stents. Radiology 162: 481–485
Uchida BT, Putnam JS, Rosch J (1987) Atraumatic transjugular needle for portal vein puncture in swine. Radiology 163: 580–581
Maynar M, Cabrera 1, Pulido-Duque JM, {eaet al.} Transjugular intrahepatic portosystemic shunt: early experience with a flexible trocar/catheter system. AJR 161: 301–306
Longo JM, Bilbao JI, Rousseau HP, et al. Transjugural intrahepatic portosystemic shunt: evaluation with Doppler sonography. Radiology 186: 529–534
Surratt RS, Middleton WD, Darcy MD, Melson GL, Brink JA (1993) Morphologic and hemodynamic findings at sonography before and after creation of a transjugular intrahepatic portosystemic shunt. AJR 160: 627–630
Somberg KA, Riebler JI, Doherty M, et al. (1992) Hepatic encephalopathy following TIPS: incidence and risk factors. Hepatology 16: 122A
Sellinger M, Haag K, Ochs A, Nöldge G, Gerok W, Rössle M (1992) Factors influencing the incidence of hepatic encephalopathy in patients with TIPS. Hepatology 16: 122A
Radosevich PM, Ring EJ, LaBerge JM, et al. (1993) Transjugular intrahepatic portosystemic shunts in patients with portal vein occlusion. Radiology 186: 523–527
Chalmers N, Redhead DN, Simpson KJ, Hayes PC (1992) Transjugular intrahepatic portosystemic stent shunt: early clinical experience. Clin Radiol 46: 166–169
LaBerge JM, Ring EJ, Gordon RL, et al. (1993) Creation of transjugular intrahepatic portosystemic shunts with the Wallstent endoprothesis: results in 100 patients. Radiology 187: 413–420
Cwikiel W, Stridbeck H (1992) Experimental transjugular portocaval shunt. Acta Radiol 33: 356–359
Haskal ZJ, Ring EJ, LaBerge JM, et al. Role of parallel transjugular intrahepatic portosystemic shunts in patients with persistent portal hypertension. Radiology 185: 813-817
Benner K, Sahagun G, Meyer RA, et al. (1993) Shunt patency after transjugular intrahepatic portosystemic shunt. Gastroenterology 104: 876A
Author information
Authors and Affiliations
Additional information
Correspondence to: A. Krajina
Rights and permissions
About this article
Cite this article
Krajina, A., Hůlek, P., Eliáš, P. et al. Transjugular intrahepatic portosystemic shunts with Spiral Z stents: first clinical experience in 20 patients. Eur. Radiol. 4, 425–429 (1994). https://doi.org/10.1007/BF00212814
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00212814