European Journal of Nuclear Medicine

, Volume 19, Issue 11, pp 925–932 | Cite as

Improved positron emission tomography quantification by Fourier-based restoration filtering

  • Jonathan M. Links
  • Jeffrey P. Leal
  • Hans W. Mueller-Gaertner
  • Henry N. WagnerJr.
Original Article

Abstract

Positron emission tomography (PET) images are characterized by both poor spatial resolution and high statistical noise. Conventional methods to reduce noise, such as local weighted averaging, produce further deteriorations in spatial resolution, while the use of deconvolution to recover resolution typically amplifies noise to unacceptable levels. We studied the use of two-dimensional Fourier filtering to simultaneously increase quantitative recovery and reduce noise. The filter was based on inversion of the scanner's measured transfer function, coupled with high frequency roll-off. In phantom studies, we found improvements in both “hot” and “cold” sphere quantification. Compared with ramp-only filtering, improvements in hot spot recovery for the highest accuracy filter averaged 13.6%±6.6% for spheres larger than 15 mm; improvements in cold spot recovery averaged 30.7%±4.7%. At the same time, the noise was reduced by a factor of 3 compared with ramponly filtering. Fourier-based image restoration filtering is thus capable of improving both accuracy and precision in PET.

Key words

Fourier filtering Positron emission tomography Ramp only filtering 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Bergstrom M, Eriksson L, Bohm C, Blomqvist G, Litton J (1983) Correction for scattered radiation in a ring detector positron camera by integral transformation of the projection. J Comput Assist Tomogr 7:42–50Google Scholar
  2. Budinger TF, Derenzo SE, Greenberg WL, Gullberg GT, Huesman RH (1978) Quantitative potentials of dynamic emission computed tomography. J Nucl Med 19:309–315Google Scholar
  3. Derenzo SE (1986) Mathematical removal of positron range blurring in high resolution tomography. IEEE Trans Nucl Sci 33:565–569Google Scholar
  4. Gilland DR, Tsui BMW, McCartney WH, Perry JR, Berg J (1988) Determination of the optimum filter function for SPECT imaging. J Nucl Med 29:643–650Google Scholar
  5. Goris ML, Briandet PA (1983) A clinical and mathematical introduction to computer processing of scintigraphic images. Raven, New YorkGoogle Scholar
  6. Hoffman EJ, Phleps ME, Huang SC (1983) Performance evaluation of a positron tomograph designed for brain imaging. J Nucl Med 24:245–257Google Scholar
  7. Karp JS, Daube-Witherspoon ME, Hoffman EF et al. (1991) Performance standards in positron emission tomography. J Nucl Med 32:2342–2350Google Scholar
  8. Kessler RM, Ellis JR, Eden M (1984) Analysis of emission tomographic scan data: limitations imposed by resolution and background. J Comput Assist Tomogr 8:514–522Google Scholar
  9. King MA, Doherty PW, Schwinger RB, Jacobs DA, Kidder RE, Miller TR (1983a) Fast count-dependent digital filtering of nuclear medicine images. J Nucl Med 24:1039–1045Google Scholar
  10. King MA, Doherty PW, Schwinger RB (1983b) A Wiener filter for nuclear medicine images. Med Phys 10:876–880Google Scholar
  11. King MA, Schwinger RB, Doherty PW, Penney BC (1984) Two-dimensional filtering of SPECT images using the Metz and Wiener filters. J Nucl Med 25:1234–1240Google Scholar
  12. King MA, Schwinger RB, Penney BC, Doherty PW, Bianco JA (1986) Digital restoration of indium-111 and iodine-123 SPECT images with optimized Metz filters. J Nucl Med 27:1327–1336Google Scholar
  13. King MA, Glick SJ, Penney BC, Schwinger RB, Doherty PW (1987) Interactive visual optimization of SPECT prereconstruction filtering. J Nucl Med 28:1192–1198Google Scholar
  14. Links JM, Jeremy RW, Dyer SM, Frank TL, Becker LC (1990a) Wiener filtering improves quantification of regional myocardial perfusion with thallium-201 SPECT. J Nucl Med 31:1230–1236Google Scholar
  15. Links JM, Loats HL, Loats PE, Casey M, Nutt R, Wagner HN (1990b) Simultaneous resolution recovery and noise reduction in positron tomography by Fourier filtering of 2-d projection data abstract. J Nucl Med 31:862–863Google Scholar
  16. Madsen MT, Park CH (1985) Enhancement of SPECT images by Fourier filtering the projection image set. J Nucl Med 26:395–402Google Scholar
  17. Miller TR, Goldman KJ, Epstein DM, Biello DR, Sampathkumaran KS, Kumar B, Siegel BA (1984) Improved interpretation of gated cardiac images by use of digital filters. Radiology 152:795–800Google Scholar
  18. Penney BC, Glick SJ, King MA (1990) Relative importance of the error sources in Wiener restoration of scintigramms. IEEE Trans Med Imag 9:60–70Google Scholar
  19. Todd-Pokropek A (1980) Image processing in nuclear medicine. IEEE Tran Nucl Sci NS-27:1080–1094Google Scholar

Copyright information

© Springer-Verlag 1992

Authors and Affiliations

  • Jonathan M. Links
    • 1
  • Jeffrey P. Leal
    • 1
  • Hans W. Mueller-Gaertner
    • 1
  • Henry N. WagnerJr.
    • 1
  1. 1.Divisions of Nuclear Medicine and Radiation Health SciencesThe Johns Hopkins Medical InstitutionsBaltimoreUSA

Personalised recommendations