In 54 patients fractures of the long bones were stabilized with limited-contact dynamic compression plates (LC-DCP) made of titanium. The implant surfaces were anodized to an interference colour of gold. The surface morphology effects the tissue response to the implant and was therefore examined. At implant retrieval, about 18 months post operatively (range 11 to 27), samples of the soft tissue layer covering the plate were excised and analysed by histomorphometrical means. The aim was to study the soft tissue reactions at the implant site and further to correlate it to the clinical symptoms of the patients. At retrieval the plates were covered by a connective tissue layer of 2 mm thickness on average. In patients with local pain a comparatively significant higher number of round cells (p=0.001) and macrophages (p=0.01) was found. This is consistent with a chronic granulomatous inflammatory reaction. The localized tissue discoloration observed in about half of the patients was confirmed as being due to titanium, but it was not the focus of a cellular reaction and was not correlated with pain. In general the implant showed good biocompatibility with excellent or good clinical results in 96% of patients.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    T. P. RUEDI, Hefte Unfallheikunde 123 (1975) 1.Google Scholar
  2. 2.
    P. G. LAING, National Bureau of Standards, Special Publication (Washington DC, 1977) p. 31.Google Scholar
  3. 3.
    B. A. RAHN, V. GERET, C. CAPAUL, M. LARDI and B. SOLOTHURNMANN in “Morphometric evaluation of tissue reaction to implants using low cost digitizing techniques”, edited by A.J.C. LEE, T. ALBREKTSSON and P.J. BRANEMARK (John Wiley and Sons Ltd, Chichester, 1982) p. 263.Google Scholar
  4. 4.
    T. N. SALTHOUSE and B. F. MATLAGA, in “Biomaterials in reconstructive surgery”, edited by L. R. RUBIN (Mosby, St Louis, 1983) p. 40.Google Scholar
  5. 5.
    T. ALBREKTSSON, CRB Crit. Rev. Biocomp. 1 (1985) 53.Google Scholar
  6. 6.
    S. M. PERREN and O. POHLER, AO/ASIF Dialogue 1 (1987) 11.Google Scholar
  7. 7.
    R. L. WILLIAMS and D. F. WILLIAMS, J. Biomed. Mater. Res. 23 (1989) 339.Google Scholar
  8. 8.
    S. M. PERREN, K. KLAUE, O. POHLER, M. PREDIERI, S. STEINEMANN and E. GAUTIER, Arch. Orthop. Trauma Surg. 109 (1990) 304.Google Scholar
  9. 9.
    L. LINDER and J. LUNDSKOG, Injury 6 (1975) 277.Google Scholar
  10. 10.
    J. P. SIMPSON, in “Biological and biomechanical performance of biomaterials”, edited by P. CHRISTEL, A. MEUNIER, and A.J.S. LEE (Elsevier, Amsterdam, 1986) p. 63.Google Scholar
  11. 12.
    J. DISEGI and H. WYSS, Orthopedics 12 (1989) 75.Google Scholar
  12. 13.
    P. I. BRANEMARK, U. BREINE, J. LINDSTROM, R. ADELL, B. O. HASSON and A. OHLSSON, Scand. J. Plast. Reconstr. Surg. 3 (1969) 81.Google Scholar
  13. 14.
    U. N. RIEDE, T. RUEDI and F. LIMACHER, Arch. Orthop. Unfall, Chir. 79 (1974) 205.Google Scholar
  14. 15.
    S. G. STEINEMANN and P. A. MAEUSLI, in Proceedings of Sixth World Conference on Titanium, Cannes, June 1988, p. 535.Google Scholar
  15. 16.
    G. L. De LANGE and K. DONATH, Biomaterials 10 (1989) 121.Google Scholar
  16. 17.
    M. S. PETERS, A. L. SCHROETER, H. M. VAN HALE and J. C. BROADBENT, Contact Dermatitis 11 (1984) 214.Google Scholar
  17. 18.
    T. ALBREKTSSON, P. L. BRANEMARK, H. A. HANSSON, B. KASEMO, K. LARSSON, I. LUNDSTROEM, D. H. MCQUEEN and R. SKALAK, Ann. Biomed. Engng 11 (1983) 1.Google Scholar
  18. 19.
    M. SCHMIDT, Osteologie 1 (1992) 222.Google Scholar
  19. 20.
    J. E. SUNDGREN, P. BODOE and I. LUNDSTROEM, J. Colloid. Interface Sci. 110 (1986) 9.Google Scholar
  20. 21.
    J. LAUSMAA, Theses for Physics University of Göteborg (1991) p. 360.Google Scholar
  21. 22.
    B. A. RAHN, H. W. GERBER, J. SIMPSON, F. STRAUMANN and S. M. PERREN, Biomaterials (1980) 39.Google Scholar
  22. 23.
    E. J. ANDREWS, P. W. TODD and N. E. KUKULINSKI, J. Biomed. Mater. Res. 13 (1979) 173.Google Scholar
  23. 24.
    K. J. BUNDY, O. C. ROBERTS, K. O'CONNOR, B. RAHN and V. MCLOED, in Proceedings of 10th European Conference on Biomaterials, Davos, September 1993, p. 14.Google Scholar
  24. 25.
    A. UNGERSBOECK and B. RAHN, J. Mater. Sci. Mater. Med. 5 (1994) 434.Google Scholar
  25. 26.
    A. UNGERSBOECK, U. SCHLEGEL and B. RAHN, J. Mater. Sci. Mater. Med. 5 (1994) 557.Google Scholar
  26. 27.
    M. E. MUELLER, M. ALLGOEWER, R. SCHNEIDER and H. WILLENEGGER, in “Manual of internal fixation”, 3rd Edn (Springer Verlag, Heidelberg, 1991) p. 74.Google Scholar
  27. 28.
    M. E. MUELLER, S. NAZARIAN, P. KOCH, in “Classification AO of fractures” (Springer Verlag, Heidelberg, 1987) p. 158.Google Scholar
  28. 29.
    O. BUCHER, in “Cytologie histologie und mikroskopische anatomie des menschen” (Verlag Hans Huber Bern, Zehnte Auflage, 1980) p. 100.Google Scholar
  29. 30.
    S. C. WOODWARD and T. N. SALTHOUSE, in “Handbook of biomaterials evaluation-scientific, technical and clinical testing of implant materials” (Von Recum AF, Macmillian New York, 1986) p. 364.Google Scholar
  30. 31.
    W. F. GANONG, in “Review of medical physiology”, 8th Edn (Lange Medical Publications, Los Altos, USA, 1977) p. 646.Google Scholar
  31. 32.
    S. L. ROBBINS and R. S. COTRAN, in “Pathologic basis of disease”, 2nd edn (Saunders, Philadelphia, 1979) p. 56.Google Scholar
  32. 33.
    D. G. VINCE, J. A. HUNT and D. F. WILLIAMS, Biomaterials 12 (1991) 731.Google Scholar
  33. 34.
    J. A. HUNT, A. UNGERSBOECK and D. F. WILLIAMS, J. Mater. Sci. Mater. Med. 5 (1994) 381.Google Scholar
  34. 35.
    C. A. DINARELLO. Rev. Infect. Dis. 6 (1984) 51.Google Scholar
  35. 36.
    B. VERNON ROBERTS, in “The macrophage” (Cambridge University Press, Cambridge, 1972) p. 120.Google Scholar
  36. 37.
    Unpublished observations of the author.Google Scholar
  37. 38.
    S. HIERHOLZER and G. HIERHOLZER, “Internal fixation and metal allergy” (Georg Thieme Verlag, New York, 1992) p. 33.Google Scholar

Copyright information

© Chapman & Hall 1995

Authors and Affiliations

  • A. Ungersboeck
    • 1
  • V. Geret
    • 1
  • O. Pohler
    • 1
  • M. Schuetz
    • 2
  • W. Wuest
    • 3
  1. 1.AO/ASIF Research InstituteDavosSwitzerland
  2. 2.AO/ASIF DocumentationDavosSwitzerland
  3. 3.Institute for PathologyCantonal Hospital ChurChurSwitzerland

Personalised recommendations