Abstract
The separation of flange from beam web at slotted web connection improves many weaknesses of connection. Increasing ductility and elimination of the shear force present in beam flanges are benefits of this connection. In this article, the seismic behavior of this connection on IPE cross-sections is investigated with analytical methods and experimental testing, while considering effective factors in design. Using vertical flange stiffener on this connection is strongly impressive in improvement behavior of this connection. Considering design measures, results show no strength reduction in this part, compared to its non-slotted counterpart, and indicate lower strain gradient in beam flange welds. Performance comparisons on experimental study are made based on the total rotation, maximum resistance and energy dissipation of the specimens. Suitable ductility at this connection show that this connection stands in special moment connection class. More participation of panel zone in earthquake energy absorption reduces the total ductility of this connection and its maximum resistance.
Article PDF
Similar content being viewed by others
References
Richard, R.M., Allen, C.J., & Partridge, C.E., 1997a, “Proprietary Slotted Beam Conections Designs”, Journal of modern Steel Construction
Richard, R.M., Allen, C.J., and Partridge, C.E., 1997b, “Steel Frame Stress Reduction Connection”, United State Patent Application Publication
EL-Tawil, Sh., Mikesell, T., Vidarsson, E., & Kunnath, S. K., 1998, “Strength and Ductility of FR Welded-Bolted Connections”, SAC Steel Project. Report. SAC/BD98/01
ICC Evaluation Service, INC, 2002, “Slotted Web Beam-To-Column Steel Moment Frame Connection”, Division: 05-Metals, Section: 05120-Structural Steel, California.
Federal Emergency Management Agency (FEMA), 2000, “Seismic Design Criteria for Steel Moment-Frame Structures”, FEMA 350 and 355D.
American Institute of Steel Construction, INC., 2010, “Seismic Provisions for Structural Steel Buildings”, AISC/ANSI 341–10.
Department of Civil & Env. Engineering, Stanford University (SAC), 2000, “Development of Loading Histories For a Testing of Steel Beam-to-Column assemblies”. SAC Background Report SAC/BD-00/10.
ANSYS, User’s Manual, 1992, Theory, Swanson Analysis Systems, Inc, Vol. IV.
EL-Tawil, S., E. Vidarsson, T. Mikesell and S. K. Kunnath, 1999. “Inelastic Behavior And Design of Steel Panel Zones.” Journal of Structural Engineering 125(2): 183–193.
Kim, T., A. Whittaker, A. Gilani, V. Bertero and S. Takhirov, 2002. “Cover-Plate and Flange-Plate Steel Moment-Resisting Connections.” Journal of Structural Engineering 128(4): 474–482.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.
The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.
To view a copy of this licence, visit https://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Ghasem Vetr, M., Ghaffari, F. Effect of vertical flange stiffener on ductility of slotted web exclusive connection on (I)-shape profiles through experimental investigation. J Engin Res 3, 34 (2015). https://doi.org/10.7603/s40632-015-0034-3
Received:
Revised:
Accepted:
Published:
DOI: https://doi.org/10.7603/s40632-015-0034-3