Fabrication and Dosimetric Evaluations of a Dummy Eye Shield for Radiotherapy

  • Published:
Journal of the Korean Physical Society Aims and scope Submit manuscript

Abstract

The purpose of this study was to fabricate a dummy eye shield by using a 3D scanner and 3D printer and to compare the dose distribution calculated using the computed tomography (CT) value assignment function in the commercial radiation treatment planning (RTP) system with the dummy eye shield to dose distribution measured with a metal shield by using EBT 2 film. The tungsten eye shield was scanned using a 3D scanner (GOM ATOS ScanBox; GOM, Braunschweig, Germany), and the designed dummy eye shield was printed with a 3D Printer (Stratasys Object 500 Connex; Stratasys Ltd., Minnesota, USA) using VeroWhite (Stratasys Ltd., Minnesota, USA). A 6-MeV electron beam from a 21EX-S linear accelerator (Varian Medical System, Palo Alto, USA) was used in this study. For a 6-MeV electron beam, the absolute doses at a 10-mm depth from RTP system calculations, EBT2 films, and TLD chips were 18.8, 32.4, and 35.6 cGy, respectively. The dummy eye shield could be adopted effectively to treat ocular tumors with electron radiotherapy; however, its use with a commercial RTP system for calculating the dose distribution was difficult.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. P. T. Finger, Surv. Ophthalmol. 54, 545 (2009).

    Article  Google Scholar 

  2. Q.-T. Le et al., Int. J. Radiat. Oncol. Biol. Phys. 52, 657 (2002).

    Article  Google Scholar 

  3. P. Zhou et al., Int. J. Radiat. Oncol. Biol. Phys. 63, 866 (2005).

    Article  Google Scholar 

  4. S. Ohga et al., Anticancer Res. 33, 5575 (2013).

    Google Scholar 

  5. S.-K. Kang et al., Med. Dosim. 40, 240 (2015).

    Article  Google Scholar 

  6. S.-K. Kang et al., J. Radiat. Res. 54, 174 (2012).

    Article  Google Scholar 

  7. K. Hayashi et al., Ophthalmologica 223, 96 (2009).

    Article  Google Scholar 

  8. S. Bhatia et al., Int. J. Radiat. Oncol. Biol. Phys. 54, 818 (2002).

    Article  Google Scholar 

  9. R. D. Weaver, B. J. Gerbi and K. E. Dusenbery, Int. J. Radiat. Oncol. Biol. Phys. 41, 233 (1998).

    Article  Google Scholar 

  10. S. H. Benedict et al., Med. Phys. 37, 4078 (2010).

    Article  Google Scholar 

  11. K. Fukutsu et al., Radiat. Oncol. 13, 95 (2018).

    Article  Google Scholar 

  12. M. M. Rehani, E. Vano, O. Ciraj-Bjelac and N. J. Kleiman, Radiat. Prot. Dosimetry 147, 300 (2011).

    Article  Google Scholar 

  13. K. R. Brown and E. Rzucidlo, J. Vascu. Surg. 53, 15S (2011).

    Article  Google Scholar 

  14. V. S. E. Jeganathan, A. Wirth and M. P. MacManus, Int. J. Radiat. Oncol. Biol. Phys. 79, 650 (2011).

    Article  Google Scholar 

  15. C. Mayo et al., Int. J. Radiat. Oncol. Biol. Phys. 76, S28 (2010).

    Article  Google Scholar 

  16. H. V. Danesh-Meyer, J. Clin. Neurosci. 15, 95 (2008).

    Article  Google Scholar 

  17. J. W. Park, S. A. Oh, J. W. Yea and M. K. Kang, PloS One 12, e0177562 (2017).

    Article  Google Scholar 

  18. J. W. Yea et al., PloS One 12, e0181560 (2017).

    Article  Google Scholar 

  19. S. A. Oh et al., Prog. Med. Phys. 28, 100 (2017).

    Article  Google Scholar 

  20. S. A. Oh et al., Prog. Med. Phys. 28, 106 (2017).

    Article  Google Scholar 

  21. https://www.rpdinc.com/tungsten-eye-shields-695.

  22. S. A. Oh et al., J. Korean Phys. Soc. 60, 1973 (2012).

    Article  ADS  Google Scholar 

  23. S. A. Oh et al., Prog. Med. Phys. 25, 218 (2014).

    Article  Google Scholar 

  24. Varian Medical System, Eclipse Photon and Electron Algorithms Reference Guide (Palo Alto, CA, 2015).

    Google Scholar 

Download references

Acknowledgments

This work was supported a National Research Foundation of Korea (NRF-2017R1C1B5074465) grant funded by the Korea Government (Ministry of Science and ICT).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jae Won Park.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Oh, S.A., Park, J.W. Fabrication and Dosimetric Evaluations of a Dummy Eye Shield for Radiotherapy. J. Korean Phys. Soc. 75, 605–609 (2019). https://doi.org/10.3938/jkps.75.605

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3938/jkps.75.605

PACS numbers

Keywords

Navigation