Abstract
The purpose of this study was to fabricate a dummy eye shield by using a 3D scanner and 3D printer and to compare the dose distribution calculated using the computed tomography (CT) value assignment function in the commercial radiation treatment planning (RTP) system with the dummy eye shield to dose distribution measured with a metal shield by using EBT 2 film. The tungsten eye shield was scanned using a 3D scanner (GOM ATOS ScanBox; GOM, Braunschweig, Germany), and the designed dummy eye shield was printed with a 3D Printer (Stratasys Object 500 Connex; Stratasys Ltd., Minnesota, USA) using VeroWhite (Stratasys Ltd., Minnesota, USA). A 6-MeV electron beam from a 21EX-S linear accelerator (Varian Medical System, Palo Alto, USA) was used in this study. For a 6-MeV electron beam, the absolute doses at a 10-mm depth from RTP system calculations, EBT2 films, and TLD chips were 18.8, 32.4, and 35.6 cGy, respectively. The dummy eye shield could be adopted effectively to treat ocular tumors with electron radiotherapy; however, its use with a commercial RTP system for calculating the dose distribution was difficult.
Similar content being viewed by others
References
P. T. Finger, Surv. Ophthalmol. 54, 545 (2009).
Q.-T. Le et al., Int. J. Radiat. Oncol. Biol. Phys. 52, 657 (2002).
P. Zhou et al., Int. J. Radiat. Oncol. Biol. Phys. 63, 866 (2005).
S. Ohga et al., Anticancer Res. 33, 5575 (2013).
S.-K. Kang et al., Med. Dosim. 40, 240 (2015).
S.-K. Kang et al., J. Radiat. Res. 54, 174 (2012).
K. Hayashi et al., Ophthalmologica 223, 96 (2009).
S. Bhatia et al., Int. J. Radiat. Oncol. Biol. Phys. 54, 818 (2002).
R. D. Weaver, B. J. Gerbi and K. E. Dusenbery, Int. J. Radiat. Oncol. Biol. Phys. 41, 233 (1998).
S. H. Benedict et al., Med. Phys. 37, 4078 (2010).
K. Fukutsu et al., Radiat. Oncol. 13, 95 (2018).
M. M. Rehani, E. Vano, O. Ciraj-Bjelac and N. J. Kleiman, Radiat. Prot. Dosimetry 147, 300 (2011).
K. R. Brown and E. Rzucidlo, J. Vascu. Surg. 53, 15S (2011).
V. S. E. Jeganathan, A. Wirth and M. P. MacManus, Int. J. Radiat. Oncol. Biol. Phys. 79, 650 (2011).
C. Mayo et al., Int. J. Radiat. Oncol. Biol. Phys. 76, S28 (2010).
H. V. Danesh-Meyer, J. Clin. Neurosci. 15, 95 (2008).
J. W. Park, S. A. Oh, J. W. Yea and M. K. Kang, PloS One 12, e0177562 (2017).
J. W. Yea et al., PloS One 12, e0181560 (2017).
S. A. Oh et al., Prog. Med. Phys. 28, 100 (2017).
S. A. Oh et al., Prog. Med. Phys. 28, 106 (2017).
S. A. Oh et al., J. Korean Phys. Soc. 60, 1973 (2012).
S. A. Oh et al., Prog. Med. Phys. 25, 218 (2014).
Varian Medical System, Eclipse Photon and Electron Algorithms Reference Guide (Palo Alto, CA, 2015).
Acknowledgments
This work was supported a National Research Foundation of Korea (NRF-2017R1C1B5074465) grant funded by the Korea Government (Ministry of Science and ICT).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Oh, S.A., Park, J.W. Fabrication and Dosimetric Evaluations of a Dummy Eye Shield for Radiotherapy. J. Korean Phys. Soc. 75, 605–609 (2019). https://doi.org/10.3938/jkps.75.605
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.3938/jkps.75.605