Skip to main content
Log in

GEANT4-based Monte Carlo Simulation of Beam Quality Correction Factors for the Leksell Gamma Knife® Perfexion™

  • Published:
Journal of the Korean Physical Society Aims and scope Submit manuscript

Abstract

With the publication of TRS-483 in late 2017 the IAEA has established an international code of practice for reference dosimetry in small and non-standard fields based on a formalism first suggested by Alfonso et al. in 2008. However, data on beam quality correction factors (\(k_{{Q_{msr,}}{Q_0}}^{{f_{msr,}}{f_{ref}}}\)) for the Leksell Gamma Knife® Perfexion™ is scarce and what little data is available was obtained under conditions not necessarily in accordance with the IAEA’s recommendations. This study constitutes the first systematic attempt to calculate those correction factors by applying the new code of practice to Monte Carlo simulation using the GEANT4 toolkit. \(k_{{Q_{msr,}}{Q_0}}^{{f_{msr,}}{f_{ref}}}\) values were determined for three common ionization chamber detectors and five different phantom materials, with results indicating that in most phantom materials, all chambers were well suited for reference dosimetry with the Gamma Knife®. Similarities and differences between the results of this study and previous ones were also analyzed and it was found that the results obtained herein were generally in good agreement with earlier PENELOPE and EGSnrc studies.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. International Atomic Energy Agency, Absorbed dose determination in external beam radiotherapy: an international code of practice for dosimetry based on standards of absorbed dose to water, Technical Report Series No. 398, Vienna (2000).

  2. P. R. Almond et al., Med. Phys. 26, 1847 (1999).

    Article  Google Scholar 

  3. Institute of Physics and Engineering in Medicine, Small field MV photon dosimetry, IPEM Report No. 103, York (2010).

  4. R. Alfonso et al., Med. Phys. 35, 5179 (2008).

    Article  Google Scholar 

  5. International Atomic Energy Agency, Dosimetry of small static fields used in external beam radiotherapy: an IAEA-AAPM international code of practice for reference and relative dose determination, Technical Report Series No. 483, Vienna (2017).

  6. J. Johansson et al., Presentation at the 16th International Meeting of the Leksell Gamma Knife® Society, Sydney (2012).

    Google Scholar 

  7. E. Zoros et al., Phys. Med. Biol. 62, 7532 (2017).

    Article  Google Scholar 

  8. L. Mirzakhanian, H. Benmakhlouf, F. Tessier and J. Seutjens, Med. Phys. 45, 1748 (2018).

    Article  Google Scholar 

  9. C. Lindquist and I. Paddick, Operative Neurosurgery 61, ONS–131 (2007).

    Article  Google Scholar 

  10. C. M. Poole et al., IEEE Trans. Nucl. Sci. 59, 1695 (2012).

    Article  ADS  Google Scholar 

  11. T. H. Kim et al., Development of IAEA phase-space database for Leksell Gamma Knife®-PerfexionTM using multi-threaded GEANT4 simulation, Phys. Med. Biol. (2018) (under review).

    Google Scholar 

  12. EStar material composition database of the US National Institute of Standards and Technology, https://doi.org/physics.nist.gov/cgi-bin/Star/compos.pl.

  13. F. Araki, Physica Medica 39, 132 (2017).

    Article  Google Scholar 

  14. J. Novotny Jr. et al., Med. Phys. 37, 5066 (2010).

    Article  Google Scholar 

  15. Homepage of the GEANT4 simulation toolkit at CERN, https://doi.org/geant4.web.cern.ch/.

  16. S. Incerti, M. Asai and D. Wright, GEANT4 Tutorial at KIRAMS, Seoul, Korea, (2017) (https://doi.org/geant4.in2p3.fr/IMG/pdfPhysicsLists.pdf).

    Google Scholar 

  17. British Institute of Radiology, Central Axis Depth Dose Data for Use in Radiotherapy, British Journal of Radiology Supplement 25, London (1996).

  18. J. Allison et al., Nucl. Instrum. Meth. Phys. Res. A 835, 186 (2015).

    Article  ADS  Google Scholar 

  19. G. M. Mora, A. Maio and D. W. Rogers, Med. Phys. 26, 2494 (1999).

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hyun-Tai Chung.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Schaarschmidt, T., Kim, T.H., Kim, Y.K. et al. GEANT4-based Monte Carlo Simulation of Beam Quality Correction Factors for the Leksell Gamma Knife® Perfexion™. J. Korean Phys. Soc. 73, 1814–1820 (2018). https://doi.org/10.3938/jkps.73.1814

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3938/jkps.73.1814

Keywords

Navigation