Skip to main content
Log in

Experimental Measurement and Monte Carlo Simulation the Correction Factor for the Medium-Energy X-ray Free-air Ionization Chamber

  • Published:
Journal of the Korean Physical Society Aims and scope Submit manuscript

Abstract

A key comparison has been made between the air-kerma standards of the National Institute of Metrology (NIM), China, and other Asia Pacific Metrology Programme (APMP) members in the medium-energy X-ray. This paper reviews the primary standard Free-air ionization chamber correction factor experimental method and Monte Carlo simulation method in the NIM. The experimental method and the Monte Carlo simulation method are adopted to obtain the correction factor for the medium-energy X-ray primary standard free-air ionization chamber at 100 kV, 135 kV, 180 kV, 250 kV four CCRI reference qualities. The correction factor has already been submitted to the APMP as key comparison data and the results are in good agreement with those obtained in previous studies. This study shows that the experimental method and the EGSnrc simulation method are usually used in the measurement of the correction factor. In particular, the application of the simulation methods is more common.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. D. T. Burns, C. Kessler and J. P. McCaffrey, Metrologia Technical Supplement 48, 06002 (2011).

    Article  Google Scholar 

  2. D. T. Burns, T. Zhongqing, L. Yazhu, W. Guoqing and F. Cheng, Metrologia Technical Supplement 44, 06008 (2007).

    Article  Google Scholar 

  3. J. J. Wu, J. N. Sun, Y. D. Yang and Y. L. Zhang, J. Acta Metrologica Sinica, 31, 555 (2010).

    Google Scholar 

  4. M. Boutillon, Physics in Medicine & Biology 43, 2061 (1998).

    Article  ADS  Google Scholar 

  5. T. Kurosawa and N. Takata. CCRI(I)/05-27 Correction factors for free-air ionization chambers for X-rays transmitted through a diaphragm edge and scattered from the surface of the diaphragm aperture.

  6. D. W. O. Rogers et al., BEAMnrc users manual. Technical Rep. PIRS-898, (2005).

  7. I. Kawrakow, EGSnrc C++ Class Library, Technical Report No. PIRS-898, 2005.

  8. E. Mainegra-Hing, N. Reynaert and I. Kawrakow, Medical Physics 35, 3650 (2008).

    Article  ADS  Google Scholar 

  9. ICRU. Fundamental Quantities and Units for Ionizing Radiation au][R]. ICRU Report 33, 1980.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jinjie Wu.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Yu, J., Wu, J., Liao, Z. et al. Experimental Measurement and Monte Carlo Simulation the Correction Factor for the Medium-Energy X-ray Free-air Ionization Chamber. J. Korean Phys. Soc. 73, 1466–1472 (2018). https://doi.org/10.3938/jkps.73.1466

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3938/jkps.73.1466

Keywords

Navigation