Skip to main content
Log in

Monte Carlo study of conversion factors for ionization chamber dosimetry in solid slab phantoms for MV photon beams

  • Published:
Journal of the Korean Physical Society Aims and scope Submit manuscript

Abstract

For high energy photon beams, solid phantom to water dose conversion factors were calculated by using a Monte Carlo method, and the result were compared with measurements and published data. Based on the absorbed dose to water dosimetry protocol, the conversion factor was theoretically divided into stopping powers ratios, perturbation factors and ratios of absorbed dose to water and that to solid phantom. Data for a Farmer-type chamber and a solid phantom based on polystyrene which is one of the most common material were applied to calculate the conversion factors for 6 MV and 15 MV photon beams. All measurements were conducted after 10 Gy pre-irradiation and thermal equilibrium had been established with solid slabs in a treatment room. The calculated and the measured conversion factors were in good agreement and could be used to confirm the feasibility of the solid phantom as a substitute for water for high energy photon beam.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. IAEA, IAEA TRS-277, 1987.

    Google Scholar 

  2. IAEA, IAEA TRS-398, 2000.

    Google Scholar 

  3. P. R. Almond, P. J. Biggs, B. M. Coursey, W. F. Hanson, M. S. Hug, R. Nath and D. W. Rogers, Med. Phys. 26, 1847 (1999).

    Article  Google Scholar 

  4. G. Christ, Med. Phys. 22, 2097 (1995).

    Article  Google Scholar 

  5. V. M. Tello, R. C. Tailor and W. F. Hanson, Med. Phys. 22, 1177 (1995).

    Article  Google Scholar 

  6. J. Seuntjens, M. Olivares, M. Evans, E. Podgorsak. Med. Phys. 32, 2945 (2005).

    Article  Google Scholar 

  7. F. Araki, Y. Hanyu, M. Fukuoka, K. Matsumoto, M. Okumura and H. Oguchi, Med. Phys. 36, 2992 (2009).

    Article  Google Scholar 

  8. M. J. Butson, T. Cheung and P. K. Yu, Med. Phys. 33, 24 (2008).

    Article  Google Scholar 

  9. D. M. Galbraith, J. A. Rawlinson and P. Munro, Med. Phys. 11, 197 (1984).

    Article  Google Scholar 

  10. L. O. Mattsson and H. Svensson, Acta. Radiol. Oncol. 23, 393 (1984).

    Article  Google Scholar 

  11. C. S. Reft, Med. Phys. 16, 299 (1989).

    Article  Google Scholar 

  12. D. Pellowitz, MCNPX User’s Manual, version 2.6.0, 2007.

    Google Scholar 

  13. D. Sheikh-Bagheri and D. Rogers, Med. Phys. 29, 391 (2002).

    Article  Google Scholar 

  14. D. S. Followill, R. C. Tailor, V. M. Tello and W. F. Hanson, Med. Phys. 25, 1202 (1998).

    Article  Google Scholar 

  15. E. G. Aird and F. T. Farmer, Phys. Med. Biol. 17, 169 (1972).

    Article  Google Scholar 

  16. L. L. Wang and D. W. Rogers, Med. Phys. 35, 1747 (2008).

    Article  Google Scholar 

  17. J. Siebers, P. Keall, A. Nahum and R. Mohan, Phys. Med. Biol. 45, 983 (2000).

    Article  Google Scholar 

  18. M. J. Berger and B. Alder, Methods in Computational Physics, edited by S. Frenbach and M. Rotenberg (Academic Press, New York, 1963), Vol. 1, p. 135.

  19. J. Wulff, J. Heverhagen and K. Zink, Phys. Med. Biol. 53, 2823 (2008).

    Article  Google Scholar 

  20. J. M. Fernandez-Varea, P. Carrasco, V. Panettieri and L. Brualla, Phys. Med. Biol. 52, 6475 (2007).

    Article  Google Scholar 

  21. G. Xiong and D. W. Rogers, Med. Phys. 35, 2104 (2008).

    Article  Google Scholar 

  22. P. Andreo, Measurement Assurance in Dosimetry (IAEA, Vienna, 1994).

    Google Scholar 

  23. J. R. Palta, K. Ayyangar, I. Daftari and N. Suntharalingam, Med. Phys. 17, 106 (1990).

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jai-ki Lee.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Park, Dw., Lee, Jk. Monte Carlo study of conversion factors for ionization chamber dosimetry in solid slab phantoms for MV photon beams. Journal of the Korean Physical Society 69, 647–652 (2016). https://doi.org/10.3938/jkps.69.647

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3938/jkps.69.647

Keywords

Navigation