Skip to main content
Log in

Alternative fiducial markers for Vero real-time tumor tracking radiotherapy: A phantom study

  • Published:
Journal of the Korean Physical Society Aims and scope Submit manuscript

Abstract

The objective of this study was to investigate the feasibility of potential fiducial markers consisting of various materials in a Vero real-time tumor-tracking (RTTT) system. In order to determine the applicability of fiducial markers for the Vero RTTT system, we tested various markers consisting of 8 kinds of material (titanium, stainless steel, high-carbon steel, pure steel, copper, silver, tantalum, and gold) with various diameters ranging from 0.3 mm to 1.6 mm and a length of 5 mm. Additionally, a commercial gold coil marker (Visicoil™, IBA dosimetry, Schwarzenbruck, Germany) of diameter 0.5 mm and length 1 cm was included for evaluation. The radiologic visibility on kV fluoroscopy/kV CT scan images of the fiducial markers was evaluated. The detectability on the RTTT system was tested using a two-dimensional moving phantom (Brainlab AG, Feldkirchen, Germany), producing sinusoidal motion. The target center’s accuracy was evaluated by calculating the deviation of the position of a metal sphere from the center on the dose profile. Dose profiles were measured using Gafchromic EBT2 films (International Specialty Products, NJ, USA). All markers were visible on kV fluoroscopy/kV CT while markers with atomic number ≥ 25.7 were detectable on the Vero RTTT system. All the detected markers showed excellent geometric accuracy.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. T. J. Scarbrough et al., Int. J. Radiat. Oncol. Biol. Phys. 65, 378 (2006).

    Article  Google Scholar 

  2. M. Imura et al., Int. J. Radiat. Oncol. Biol. Phys. 63, 1442 (2005).

    Article  Google Scholar 

  3. D. F. Abawi et al., Accuracy in optical tracking with fiducial markers: An accuracy function for ARToolKit. in Proceedings of the 3rd IEEE/ACM International Symposium on Mixed and Augmented Reality (Arlington, VA, USA, 2004).

    Google Scholar 

  4. K. M. Langen et al., Int. J. Radiat. Oncol. Biol. Phys. 71, 1084 (2008).

    Article  Google Scholar 

  5. R. I. Whyte et al., Annals Thoracic Surg. 75, 1097 (2003).

    Article  Google Scholar 

  6. E. Sotiropoulou et al., Cardiovas. Intervent. Rad. 33, 586 (2010).

    Article  Google Scholar 

  7. J. Loh et al., Rad. Oncol. 10, 38 (2015).

    Article  Google Scholar 

  8. R. Kinoshita et al., Int. J. Radiat, Oncol. Biol. Phys. 70, 931 (2008).

    Article  Google Scholar 

  9. T. Depuydt et al., Radiother. Oncol. 98, 365 (2011).

    Article  Google Scholar 

  10. K. Poels et al., Radiother. Oncol. 112, 352 (2014).

    Article  ADS  Google Scholar 

  11. T. Depuydt et al., Radiother. Oncol. 106, 236 (2013).

    Article  Google Scholar 

  12. N. Mukumoto et al., Radiother. Oncol. 111, 301 (2014).

    Article  Google Scholar 

  13. M. L. Taylor et al., Med. Phys. 39, 1769 (2012).

    Article  Google Scholar 

  14. F. M. Kahn and J. P. Gibbons, The Physics of Radiation Therapy (5th Edition, Wolters Kluwer, Lippincott Williams & Wilkins, Philadelphia, 2014), p. 63.

    Google Scholar 

  15. D. Habermehl et al., J. Radiat. Res. 54 Suppl 1, i61 (2013).

    Article  Google Scholar 

  16. J. Carl et al., Acta. Oncol. 47, 1358 (2008).

    Article  Google Scholar 

  17. S. Song et al., Radiother. Oncol. 103, 270 (2012).

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jae-Chul Kim.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Park, SH., Kim, JC. & Kim, S.J. Alternative fiducial markers for Vero real-time tumor tracking radiotherapy: A phantom study. Journal of the Korean Physical Society 69, 1700–1704 (2016). https://doi.org/10.3938/jkps.69.1700

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3938/jkps.69.1700

Keywords

PACS numbers

Navigation