Skip to main content
Log in

Designing transfer function with the required direct performance measures based on the Laplace transform

  • Modeling in Physical and Technical Research
  • Published:
Optoelectronics, Instrumentation and Data Processing Aims and scope

Abstract

An approach is proposed to design transfer functions with prescribed direct measures of transient performance: overshoot and setting time. A technique for designing such functions is developed. A numerical example is given.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. A. V. Nikitin and V. F. Shishlakov, Parametric Synthesis of Nonlinear Systems of Automatic Control (St. Petersburg State University of Aerospace Instrumentation, St. Petersburg, 2003) [in Russian].

    Google Scholar 

  2. L. N. Krivdina, Synthesis of Digital Controllers Based on Linear Matrix Inequalities: Abstract of Candidate’s Dissertation (Nizhny Novgorod State University, Nizhny Novgorod, 2009).

    Google Scholar 

  3. S. V. Efimov and M. I. Pushkarev, “Determination of Direct Performance Measures Based on the Poles and Zeros of the Transfer Function,” Avtometriya 47(3), 113–119 (2011) [Optoelectron., Instrum. Data Process. 47 (3), 2973–302 (2011)].

    Google Scholar 

  4. S. V. Efimov, S. V. Zamyatin, and S. A. Gaivoronskii, “Problems of the Root Analysis and Synthesis of Automatic Control Systems,” Izv. TPU, No. 5, 16–20 (2010).

    Google Scholar 

  5. S. V. Efimov, S. V. Zamyatin, and M. I. Pushkarev, “Synthesis of the Controller Parameters of Control Systems with Interval Parameters that Provide the Required Direct Performance Measures Taking into Account Zeros and Poles,” in System Analysis, Control and Navigation, Abst. XVII Intern. Sci. Conf. (MAI-PRINT, Moscow, 2012), pp. 81–83.

    Google Scholar 

  6. O. I. Tolochko, “Designing Transfer Functions for a Given Overshoot Taking into Account the Nature of the Decay of Transients,” Vestn. Kharkov Polytech. Univ. Nats. Tekhn. 2(10), 315–319 (2003).

    Google Scholar 

  7. D. N. Filippov, Criteria for the ɛ-Dominance of the Transfer Function Components of Linear Automatic Control Systems (Moscow Aviation Institute, Moscow, 1989), Deposited VINITI 22.05.1989, No. 4524.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to S. V. Efimov.

Additional information

Original Russian Text © S. V. Efimov, V. V. Kurgankin, S. V. Zamyatin, 2014, published in Avtometriya, 2014, Vol. 50, No. 4, pp. 34–40.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Efimov, S.V., Kurgankin, V.V. & Zamyatin, S.V. Designing transfer function with the required direct performance measures based on the Laplace transform. Optoelectron.Instrument.Proc. 50, 348–353 (2014). https://doi.org/10.3103/S8756699014040049

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3103/S8756699014040049

Keywords

Navigation