Background

Fetal surgery is being increasingly utilized to correct severe congenital defects in utero prior to birth. Over the past three decades, the field of fetal surgery has advanced rapidly with increasingly complex intrauterine procedures now performed at more than fifty fetal centers in the United States [1, 2]. These surgeries are performed at mid-gestation via maternal laparotomy and hysterotomy, or more recently, via hysterotomy-sparing endoscopy with partial amniotic carbon dioxide insufflation (PACI) to aid visualization [3,4,5]. During these complex surgeries, maternal hemodynamics, blood gases and lactate levels are continuously monitored via arterial access, but analogous parameters cannot be monitored in the fetus without invasive procedures such as arterial line placement and repeated serum blood gas analysis, which are prohibitively dangerous at mid-gestation [6].

As fetal surgeries continue to become more complex, there is concern that prolonged anesthesia and carbon dioxide insufflation may lead deleterious changes in fetal carbon dioxide levels and acid/base status, ultimately affecting fetal well-being [7, 8]. Currently two-dimensional echocardiography is used to monitor fetuses intra-operatively, [9] but this modality provides limited information on end-organ perfusion which, if compromised, could permanently affect organ development. Unfortunately, until now, there has been no reliable, non-invasive method to measure fetal brain perfusion in utero during fetal surgery.

Contrast-enhanced ultrasound (CEUS) is an emerging, minimally-invasive imaging technique that has been increasingly used to detect cerebral perfusion defects in neonates and adults [10,11,12,13]. Clinically, injection of gas-filled microbubbles allows enhanced visualization of blood vessels that rivals computed tomography without ionizing radiation and can be performed at the patient’s bedside [10, 13, 14]. We hypothesized that CEUS could be used to monitor fetal cerebral perfusion during fetal surgery. To test our hypothesis, we studied catheterized mid-gestation fetal sheep ex utero and in utero under normal and PACI conditions to simulate fetal surgery. Our objectives were to determine: (1) could CEUS be used to monitor fetal cerebral perfusion during fetal surgery, and (2) does acid/base status or hemodynamics affect perfusion parameters.

Methods

All animals were treated according to protocols approved by the Institutional Animal Care and Use Committee at the Children’s Hospital of Philadelphia. All animals were housed in an on-site animal facility. Ewes had consistent access to food and water and were allowed to feed ad libitum until the night prior to surgery.

Anesthesia protocol

Time-dated pregnant ewes were fasted and transdermal fentanyl patches (2 µg/kg/hr) were applied to animal forelimbs 12 to 18 h prior to surgery. Ewes were selected when fetuses were gestational age 102–120 days which correlates to midgestation of a human fetus in terms of neurodevelopment [15]. Ewes were anesthetized with intramuscular ketamine (15 mg/kg) and inhaled isoflurane (1–4 % in O2) and positioned in left lateral decubitus. Ventilator tidal volume (8–10 ml/kg/min) and respiratory rate (10–18) were adjusted to achieve a maternal end-tidal CO2 of 35-40mm Hg and arterial CO2 of 35–45 mm Hg.

Ex utero insufflation

Six time-dated fetuses [113 ± 5 days gestational age (GA)] were exteriorized via laparotomy and hysterotomy, cannulated via their umbilical vessels, and attached to a pumpless low resistance oxygenator circuit (Fig. 1 A). Fetal heart rate, arterial and venous blood pressure, umbilical blood flow, sweep gas flow rate and oxygen delivery were continuously measured (HT110 Bypass Meter and HXL Tubing Flowsensor Transonic Systems Inc., Ithaca, NY, USA) and recorded and (LabChart 5, ADInstruments Inc., Colorado Springs, CO, USA) as previously described [16]. During a 2-day acclimation period in this EXTrauterine Environment for Neonatal Development (EXTEND), physiologic levels of oxygen (15–20 mmHg) and carbon dioxide (38–43 mmHg) were maintained.

Fig. 1
figure 1

Experimental conditions.Fetal sheep (n=6) were cannulated via their umbilical vessels, connected to a low resistance oxygenator circuit and supported in a fluid filled environment. b The fluid filled bag was partially drained and insufflated to 8 mm Hg with carbon dioxide to simulate fetal surgery.The amniotic cavities of time-dated ewes (n=4) were insufflated with carbon dioxide to simulate fetal surgery

After two days, the sterile extra-uterine environment was partially drained of fluid and insufflated with CO2, helium or nitrogen to 8 mmHg for 4 h (Karl Storz, Endoscopy Tuttlington, Germany) to mimic fetoscopic surgery conditions (Fig. 1B). Oxygenator sweep gas flow was held constant throughout the experimental period. Serial blood gases (i-Stat System, Abbott Point of Care Inc., Princeton, NJ, USA) were obtained and CEUS examinations were performed every 28 ± 9 min during insufflation as fetal positioned allowed. After a two-day recovery period and normalization of blood gas and hemodynamic variables, insufflation was repeated in these animals up to 5 occasions for a total of 20 experiments.

In Utero Insufflation

A mid-line laparotomy was performed, and the head of the fetus was exteriorized through a small hysterotomy at GA 103 ± 2. The fetal carotid artery was cannulated via neck incision with a polyvinyl catheter (ID 0.040”, Scientific Commodities, Lake Havasu, AZ). The carotid catheter was exteriorized and secured to the ewe’s flank. Prior to hysterotomy closure, amniotic fluid was replaced with warmed lactated ringers and treated with penicillin G (1 million units). The hysterotomy and laparotomy were closed, and ewes recovered from surgery.

After 2 days of recovery, baseline fetal arterial blood gas samples were obtained and ewes re-anesthetized. Fetuses GA 105 ± 2 days were evaluated in the operating room under maternal anesthesia with (n = 4) or without (n = 3) intra-amniotic CO2 insufflation to 8 mmHg for 4 h with continuous hemodynamic assessment and serial blood gas analysis (Fig. 1 C). Throughout the surgical procedures, CEUS examinations were performed every 20 min.

Ultrasound evaluation

CEUS examinations of the brain were performed by a board-certified radiologist throughout the ex utero and in utero studies. All imaging was performed with a C2-9 MHz transducer on a commercially-available GE Loqiq E9 ultrasound system with contrast capabilities (GE Healthcare, Chicago, IL, USA).

Lumason® (sulfur hexafluoride lipid-type A microspheres; Bracco Diagnostics Inc., Monroe Township, NJ, USA) ultrasound contrast agent was administered as a bolus via the fetal umbilical vein (ex utero, 0.2mL) or via fetal arterial catheter (in utero, 0.3mL) with simultaneous ultrasound cine acquisition. Previous literature has documented CEUS safety data in the EXTEND model [17]. Ninety-second cine clips were obtained of the brain in a transaxial (ex utero) or coronal (in utero) plane which included the thalami (Figs. 2 and 3). CEUS examinations were analyzed (AS) using VueBox™ (Bracco Imaging Suisse SA, Geneva, Switzerland). Regions-of-interest were placed to include the entire brain and time-intensity-curves were created. Perfusion metrics known to correlate with cerebral blood flow were obtained from the analyzed datasets including time-to-peak intensity (TTP), rise time (RT), fall time (FT), and transit time (TT). Due to the presence of recirculating ultrasound contrast material in this model, which artificially increases the software-generated mean transit time, TT was defined as RT + FT for the purposes of analysis [10, 13, 18, 19]. CEUS examinations were excluded from analysis if quality of time-intensity-curve fit was < 80 % with analyzed examinations represented in the flowchart (Fig. 4).

Fig. 2
figure 2

Representative images from contrast-enhanced ultrasound examinations through the fetal brain in at various timepoints during ex utero transaxial imaging evaluation with a, grayscale image for localization including thalami (arrows), brain parenchyma (asterisks), and midline denoted by the dotted line and b, baseline contrast optimized image. Following bolus ultrasound contrast administration, brain parenchymal perfusion is visualized at c, early wash-in, d, maximum enhancement of the thalami (arrows) and brain parenchyma (asterisks), e, early wash-out, and f, late wash-out

Fig. 3
figure 3

In utero contrast-enhanced ultrasound examination through the fetal brain in a coronal plane with a, grayscale image for localization including thalami (arrows), brain parenchyma (asterisks), and midline denoted by the dotted line and b, baseline image optimized for contrast visualization. Following bolus contrast administration, brain parenchymal perfusion is visualized at c, early wash-in, d, at maximum enhancement of the thalami (arrows) and brain parenchyma (asterisks), e, early wash-out, and f, late wash-out

Fig. 4
figure 4

Flowchart depicting the number of contrast-enhanced ultrasound examinations performed in each study group

Fig. 5
figure 5

Relationship between representative brain perfusion parameters and serum laboratory values (n = 20 experiments). Predictive margins following mixed effects linear regression analyses of brain perfusion parameters and serum laboratory values from ex utero contrast-enhanced ultrasound examinations were plotted for a, transit time and pCO2 and b, transit time and pH. Error bars show the standard error

Fig. 6
figure 6

Evaluation of serum laboratory values and fetal heart rate in non-insufflated control fetuses (n = 3) and insufflated fetuses (n = 4) over time. In uteroa, pH and b, arterial carbon dioxide levels increased significantly in insufflated fetuses versus non-insufflated control fetuses. c Oxygen levels and d, heart rate were unchanged in insufflated fetuses versus non-insufflated control fetuses. Data shown as mean ± standard deviation

Statistical analysis

For extra-uterine experiments, hemodynamic parameters and arterial blood gas measurements were compared over time using mixed effects linear regression models with animal and study date analyzed as random effects. For in utero experiments, fetal hemodynamic parameters (heart rate and blood pressure) and arterial blood gas measurements for insufflated and control animals were compared over time using two-way repeated measure analysis of variance. Perfusion parameters obtained from ex utero and in utero studies were plotted over time and lines of best fit were obtained for each perfusion parameter. Mixed effects linear regression models were used to explore the relationships between perfusion variables and simultaneously obtained hemodynamic (heart rate, mean arterial pressure) and serial blood gas measurements. All data are presented as mean ± standard deviation, unless otherwise stated. Significance was accepted at p ≤ 0.05. GraphPad, version 5.0 (Prism, GraphPad Software, Inc. La Jolla, CA) and Stata, version 15 (Stata Statistical Software: Release 15, StataCorp LLC, College Station, TX) were used for statistical analysis and graphical depictions of data.

Results

Ex utero insufflation

Fetuses were insufflated for a total of 20 experiments within the EXTEND system for 4 h with one exception, one study was terminated early due to animal movement resulting in transient hemodynamic instability. The ultimate CEUS examination occurred at 218 ± 37 min from insufflation initiation. Table 1 shows fetal hemodynamics and blood gas measurements. Throughout the study periods, fetal heart rate, mean arterial pressure and arterial oxygen content did not change significantly. In contrast, fetal CO2 increased over the study period from a baseline of 34 ± 3 to 43 ± 11 (p = < 0.01) and pH declined from a baseline of 7.37 ± 0.04 to 7.24 ± 0.08 (p = < 0.01).

Table 1 Fetal variables (n=20 experiments) over time in ex utero support device

Table 2 shows the relationship between CEUS perfusion parameters and measured fetal variables from mixed effect linear regression models. There is no significant relationship between any CEUS perfusion parameter and fetal oxygen content, bicarbonate level, heart rate or mean arterial pressure. There was a significant positive correlation between all perfusion parameters and pH and a significant negative correlation between all perfusion parameters and pCO2.

Table 2 Relationship between CEUS perfusion parameters and fetal variables (n=20 experiments)

As an example of these relationships, post-estimation predictive margins following the mixed effects linear regression analyses were plotted for (Fig. 5 A) transit time and pCO2 and (Fig. 5B) transit time and pH. Perfusion parameters decline with acidosis and hypercapnia despite stability of fetal hemodynamics and arterial oxygen content (Table 1).

In Utero Insufflation

Compared to non-insufflated fetuses, insufflated fetuses had significantly decreased pH levels and significantly increased arterial CO2 levels (Fig. 6 A-B). There was no difference in fetal arterial oxygen levels between non-insufflated and insufflated fetuses throughout the study period (21 ± 3 vs. 20 ± 3 mm Hg, p = 0.76) (Fig. 6 C). Fetal heart rate (143 ± 3 vs. 145 ± 13 beats per minute, p = 0.84) (Fig. 6D) and mean arterial pressure (40 ± 6 vs. 42 ± 3 mmHg, p = 0.73) were also maintained with no difference between groups throughout the anesthesia period.

Insufflated fetuses had significantly reduced TTP (4.05 ± 0.56 vs. 7.73 ± 1.26 s, p = 0.03), RT (2.65 ± 0.38 vs. 5.24 ± 0.58 s, p = 0.01), FT (5.34 ± 0.79 vs. 11.52 ± 1.07 s, p < 0.01) and TT (7.99 ± 1.17 vs. 16.76 ± 1.50 s, p < 0.01) compared to non-insufflated fetuses (Fig. 6 A-B).

Discussion

In this study we utilized ex utero and in utero models to demonstrate that CEUS could be used to monitor fetal cerebral perfusion during fetal surgery. Furthermore, we found that disturbances in fetal acid/base balance correlated strongly with measured perfusion parameters. These findings have important implications for the field of fetal surgery, which is rapidly expanding, and associated monitoring techniques. In the future, this technology could be used for intra-operative assessment of fetuses to detect early acid/base or perfusion disturbances.

Prolonged insufflation led to fetal acidosis and hypercapnia without significant changes in hemodynamics or oxygenation. Prior in utero insufflation studies have similarly demonstrated severe acidosis in exposed fetal sheep [5, 7, 8]. Here we show that fetuses within EXTEND still develop hypercapnic acidosis, albeit much milder than in utero fetuses. The implications of this difference between our models on human fetuses undergoing fetoscopy is unclear, particularly as differences in placentation, uterine laxity, amniotic fluid, and/or skin keratinization in fetal sheep may limit direct translation of findings to humans and future studies are aimed to better delineate the mechanisms of fetal carbon dioxide absorption. However, currently, echocardiography is used to monitor fetal heart rate, systolic function, and valvular regurgitation intra-operatively, [9] but here we showed that metabolic and brain perfusion disturbances can occur without changes in heart rate or blood pressure implying that echocardiography has limited utility in detecting these early disturbances and improved methods of detecting aberrations in fetal physiology are warranted.

Hypercapnia and acidosis cause cerebral vasodilation which results in increased cerebral blood flow [20]. Increased cerebral blood flow is particularly poorly tolerated in fetuses, because of impaired cerebral auto-regulatory mechanisms and the presence of fragile germinal matrix blood vessels [21, 22]. Therefore, early detection of acid/base or perfusion derangements is critical to prevent neurologic sequelae [21,22,23]. Our data demonstrate that CEUS can be used to measure cerebral perfusion during simulated fetal surgery. Importantly, we also showed that the measured time-dependent perfusion parameters including RT, FT, and TT, all decreased with hypercapnia and acidosis indicating faster/increased cerebral blood flow, assuming a constant fetal blood volume [10, 11]. In other words, CEUS detected increased cerebral blood flow when fetuses became acidotic or hypercapnic during fetal surgery making this a potentially useful monitoring tool during fetal surgery.

In contrast to pH and pCO2, measured cerebral perfusion parameters did not change with fetal heart rate or blood pressure. Maintenance of cerebral blood flow under these conditions suggests that lamb fetuses at this gestational age can autoregulate cerebral blood flow to a certain extent. These results, however, may underestimate the effects of fetal hemodynamics on cerebral blood flow. First, we did not evaluate volume-dependent perfusion variables such as wash-in and wash-out area under curve which may be more sensitive to changes in hemodynamics [13]. Second there was no significant change in fetal heart rate or blood pressure throughout the studies which limited our ability to study associated perfusion changes. Future studies are planned to analyze both time and volume-dependent perfusion variables over a range of hemodynamic parameters to better understand fetal autoregulation of cerebral blood flow during surgery.

Limitations

There were several additional limitations to this study which may limit clinical utility. First, contrast was delivered via umbilical vein or carotid artery which would not be feasible using current surgical methods during minimally invasive fetoscopic procedures. Prior to clinical use, trans-placental delivery of ultrasound contrast agents must be refined and is an area of ongoing research. Second, normative fetal cerebral perfusion data does not exist, so measured changes in cerebral perfusion may be difficult to interpret in early implementation of this technique. Future studies will be aimed to establish normative data and perform subsequent MRI to better understand neurologic implications of perfusion changes. Next, while we were able to demonstrate significant relationships, sample size was limited for these studies which increases the likelihood of a type two error. Finally, perfusion parameters are calculated by interpretation of contrast kinetics, and thus, is an intermittent monitoring technique. Ideally, fetal cerebral perfusion would be measured continuously during fetal surgery, and future exploration into refining contrast kinetic analyses to minimize gaps in fetal monitoring would be useful before intra-operative implementation.

Conclusions

CEUS can be used to measure cerebral perfusion during simulated fetal surgery in sheep. Importantly, we also found that measured perfusion parameters correlate with hypercapnia and acidosis which occurred during prolonged insufflation. With further development, CEUS could be a useful tool for intra-operative fetal monitoring during investigative or clinical fetal surgery.