Abstract
Background
Based on a computer-assisted literature search, this case is the first description of repeated loosening of metallic internal fixation implants after pelvic ring stabilization, associated with intravesical metal migration and micturition with expulsion of two bone screws.
Case presentation
A 62-year old woman was seen after the urinary expulsion of a 6.5 mm diameter cancellous screw. About seven years earlier, she had been hit by a motorcyclist while crossing the street. On admission at the time of the initial injury, thoraco-abdominal computerized tomography with intravenous contrast material revealed a bladder injury and pelvic ring fractures. An anterior-posterior type injury to the pelvic ring was diagnosed with symphyseal pubis disruption, and widening of the left sacroiliac joint with an associated sacral fracture. Explorative laparotomy revealed two bladder lacerations of both the posterior and the anterior bladder wall, which were repaired primarily. Orthopedic surgeons reduced the pelvis and stabilized it with two plates and screws. Seven years after the original injury, the patient presented with recurrent abdominal pain after expelling a screw into the toilet while urinating. Planar radiographs showed only five of the original screws remaining in the two symphyseal plates, and all screws appeared to have loosened when compared to the original fixation radiograph.
Conclusion
This clinical report emphasizes the importance of symphyseal plate positioning and the sequelae of imprecise positioning, especially postero-superiorly adjacent to the Retzius space. The presence of protruding metal prominences, even smooth ones like a plate corner or screw head, might endanger the bladder. When using superior plates, imprecise contouring may lead to plate edge protrusion which could damage the bladder even long after application.
Similar content being viewed by others
Background
Pelvic ring injuries with traumatic symphyseal disruption are associated with acute bladder rupture in up to 5-6 % of cases [1, 2]. In general, loosening of fixation after orthopedic repairs may occur when a fixation implant crosses a joint, or when an implant is applied to osteoporotic bone or is applied in a non-rigid fashion allowing micromotion. Bladder rupture after open reduction with internal fixation of the pelvic ring has been described previously as a late event in two cases [3, 4]. Acute bladder entrapment by external fixation has also been described [5].
Case presentation
A 62-year old woman was admitted to our Emergency Department after the urinary expulsion of a 6.5 mm diameter cancellous screw. She reported low abdominal pain and recurrent urinary tract infections during the preceding five months. About seven years earlier, she had been involved in a motor vehicle crash as a pedestrian, being hit by a motorcyclist while crossing the street. At the time of this initial injury seven years ago when admitted to the Emergency Department, she was conscious with a GCS of 15, complained of low abdominal pain and an open laceration of the left calf. On initial survey, FAST was normal and macroscopic hematuria was noted. Thoraco-abdominal computerized tomography (CT) with intravenous contrast material revealed a bladder injury and pelvic ring fractures. There was both intraperitoneal and extraperitoneal extravasation of the contrast material from the bladder into the space of Retzius. An anterior–posterior type injury to the pelvic ring was diagnosed with symphyseal pubis disruption, and widening of the left sacroiliac joint with an associated sacral fracture (Fig. 1). An explorative laparotomy confirmed the bladder laceration. There were two lacerations, one of the posterior bladder wall and a larger one involving the anterior bladder wall. The bladder was repaired primarily and the urologists protected the repairs with both urethral and suprapubic catheters. Orthopedic surgeons reduced the pelvis and stabilized it with two plates and screws; a postero-superior 4-hole, 4.5 mm dynamic compression plate (DCP) with two 6.5 mm cancellous screws on each side of the symphysis pubis and an additional antero-superior 5-hole, 3.5 mm DCP with three 4.5 mm cortical screws. An additional left-side 7.3 mm diameter x 65 mm length cannulated cancellous iliosacral screw with a washer at the level of S1 (Fig. 1) were placed. Two postoperative cystograms confirmed the absence of a bladder leak. The urinary catheters were removed successively, the suprapubic initially at three weeks postoperatively. Another cystogram performed about two months later was normal.
Seven years after the original injury, the patient presented to our Emergency Department with recurrent abdominal pain, after she had expelled a screw into the toilet while urinating. During the previous five months she had recurrent urinary tract infections. Planar radiographs were obtained and showed only five screws remaining in the two symphyseal plates. All screws appeared to have loosened (Fig. 2) when compared to the original fixation radiograph. CT scan and cystogram showed no bladder foreign bodies. However, the cystogram demonstrated 1.5-2 cm diameter bladder ulceration in the anterior wall, with the posterior pubic plate being seen through the laceration (Fig. 3). Urine culture was positive with a mixture of Staphylococcus aureus and Escherichia coli, and the patient was treated according to their antibiotic sensitivities. During her hospitalization, the patient mentioned another episode of a screw being expelled while urinating three years earlier (four years after the accident). After that episode, she reported improvement and disappearance of the low abdominal pain, without consulting a physician.
Following eradication of the bladder infection, the patient had elective surgery for removal of the symphyseal plates and repair of the bladder ulceration. The previous Pfannsetiel incision was used for exploration. A pressure ulceration of the anterior bladder wall was contiguous with the posterior-superior plate which was protruding into the bladder and associated with multiple adhesions between the outer bladder wall, the pubic bones and the Retzius space. The plates were removed and the bladder was repaired primarily in a double layer, protecting the repair again with both suprapubic and urethral catheters. Bone cultures taken during the procedure showed growth of no organisms. A cystogram two weeks later was normal without leak and the catheters were removed (Fig. 4). Two months post removal, follow-up was normal and the patient denied any additional urinary symptoms and had sterile urinary cultures.
Discussion
Urinary tract infections, especially cystitis, are common. One of the reasons for recurrent urinary tract infections is foreign bodies. Intravesical migration of a screw associated with symptoms of a urinary tract infection is uncommon. Fridman et al. described a patient who voided a screw after undergoing pelvic fixation years earlier [3]. The patient was investigated by cystoscopy which revealed that a washer had migrated into the bladder. The washer was removed and the patient was treated by urethral catheter without further urinary tract complications. Dietrick et al. [6] described an intrauterine device migration into the bladder many years after insertion. In these circumstances, the devices are usually surrounded by calcifications and associated with recurrent urinary tract infections.
Symphysis pubis internal fixation is usually performed with a single plate positioned superiorly and fixed to the left and right superior pubic rami [7, 8]. In cases which necessitate more stability, an additional plate is used, with the second plate being placed anteriorly [9]. Our patient had fixation with two plates, the first plate placed superiorly, and the second placed behind the symphysis pubis facing the Retzius space. Over the years, her screws loosened, most probably due to repetitive motion. During this process, the screw heads likely protruded posteriorly into the Retzius space, eroding and perforating the bladder wall. The first screw migrated into the bladder and was voided without clinical sequel. The episode described here occurred a few years later when a second screw had loosened, then migrated into the bladder causing recurrent cystitis until it was voided spontaneously.
Conclusion
This clinical report emphasizes the importance of symphyseal plate positioning and the sequelae of imprecise positioning, especially postero-superiorly adjacent to the Retzius space. The presence of protruding metal prominences, even smooth ones like a plate corner or screw head, might endanger the bladder. When using superior plates, imprecise contouring may lead to plate edge protrusion which could damage the bladder even long after application.
Consent
Written informed consent was obtained from the patient for publication of this Case Report and any accompanying images. A copy of the written consent is available for review by the Editor of this Journal.
Abbreviations
- GCS:
-
Glasgow coma scale
- FAST:
-
Focused assessment with sonography in trauma
- CT:
-
Computerized tomography
- DCP:
-
Dynamic compression plate
References
Avey G, Blackmore CC, Wessells H, Wright JL, Talner LB. Radiographic and clinical predictors of bladder rupture in blunt trauma patients with pelvic fracture. Acad Radiol. 2006;13:573–39.
Eid AM. Early urinary complications of fractures of the pelvis. Arch Orthop Trauma Surg. 1982;100:99–106.
Fridman M, Glass AM, Noronha JA, Carvalhal EF, Martini RK. Spontaneous urinary voiding of a metallic implant after operative fixation of the pubic symphysis: A case report. J Bone Joint Surg Am. 2003;85:1129–32.
Heetveld MJ, Poolman RW, Heldeweg EA, Ultee JM. Spontaneous expulsion of a screw during urination: an unusual complication 9 years after internal fixation of pubic symphysis diastasis. Urology. 2003;61:645.
Geracci JJ, Morey AF. Bladder entrapment after external fixation of traumatic pubic diastasis: importance of follow-up computed tomography in establishing prompt diagnosis. Mil Med. 2000;165:492–3.
Dietrick DD, Issa MM, Kabalin JN, Bassett JB. Intravesical migration of intrauterine device. J Urol. 1992;147:132–4.
Lange RH, Hansen Jr ST. Pelvic ring disruptions with symphysis pubis diastasis. Indications, technique, and limitations of anterior internal fixation. Clin Orthop Relat Res. 1985;201:130–7.
Matta JM, Saucedo T. Internal fixation of pelvic ring fractures. Clin Orthop Relat Res. 1989;242:83–97.
Tile M, Pennal GF. Pelvic disruption: principles of management. Clin Orthop Relat Res. 1980;151:56–64.
Acknowledgement
The authors thank Mrs. Myrna Perlmutter for her help in the preparation of this paper.
Author information
Authors and Affiliations
Corresponding author
Additional information
Competing interests
The authors declare that they have no competing interests.
Authors’ contributions
EP and MBH conceived and wrote the manuscript and participated in the literature review; DN and DK participated in the literature review and helped to draft the manuscript. All authors read and approved the final manuscript.
Rights and permissions
This article is published under an open access license. Please check the 'Copyright Information' section either on this page or in the PDF for details of this license and what re-use is permitted. If your intended use exceeds what is permitted by the license or if you are unable to locate the licence and re-use information, please contact the Rights and Permissions team.
About this article
Cite this article
Peled, E., Norman, D., Kakiashvili, D. et al. Recurrent episodes of micturition with expulsion of symphyseal plate screws following pelvic ring fixation: case report. BMC Musculoskelet Disord 16, 127 (2015). https://doi.org/10.1186/s12891-015-0581-7
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s12891-015-0581-7