Introduction

Carbon-fibre (CF) plates, reinforced with polyetheretherketone, have gained increasing interest due to potential advantages compared with metal plates. For instance, CF plates offer radiolucency, which enables better radiographic visualization of postoperative fracture reduction, bone healing and surveillance of tumour recurrence for oncological patients [1,2,3,4]. Furthermore, the absence of metallic artefacts allows for precise radiotherapy planning and accurate delivery after placement of CF implants [5,6,7]. Another advantage specific to CF plates may be reduced stress shielding, as their modulus of elasticity closely matches that of cortical bone; 13 gigapascal (GPa) for CF versus 12 GPa for cortical bone [8]. Additionally, in vitro studies on CF plates have demonstrated superior fatigue strength compared with current metal plates; this may potentially enhance bone healing and reduce the risk of complications [8, 9]. Finally, cold welding does not occur in CF plate constructs, which would facilitate easy implant removal [10].

Despite the increasing use of CF plates for fixating traumatic and (impending) pathological fractures, reported experience in the literature remains limited. Previous systematic reviews have primarily focused on comparative studies or specifically examined traumatic distal radius fracture fixation with CF plates [11,12,13]. In these studies, CF plates were considered as a valid alternative due to comparable results to metal plates [11,12,13]. However, cohort studies and case reports have identified several disadvantages associated with CF plates that were not mentioned in the aforementioned systematic reviews. Drawbacks include the inability to deform the plate, plate breakage without clear trauma and brittleness when plate breakage occurs [14,15,16,17]. Conducting a systematic review that includes all relevant existing evidence would provide a comprehensive overview and is crucial for assessing the safety and effectiveness of CF plates. Therefore, the aim of this systematic review was to evaluate complications associated with CF plate fixation for traumatic and (impending) fracture fixation. It also compared outcomes of patients treated with CF plates versus metal plates, aiming to determine if CF plates offered comparable results. Based on the aforementioned systematic reviews, this study hypothesized that CF plates display similar complication rates and clinical outcomes as metal plates for (pathological) fracture fixation.

Methods

Search strategy and study selection

This systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and followed a pre-registered PROSPERO protocol (CRD42021254603) [18]. A medical librarian assisted in developing the search strategy, which was based on the following population, intervention, comparison and outcome (PICO) algorithm: P = patients with traumatic or (impending) pathological fractures, I = CF plate fixation, C = no specific controls or patients treated with metal plates and O = radiological and/or clinical outcomes (including complications). Ultimately, the search was divided into two parts: (1) CF plates used for traumatic fractures and (2) CF plates used for (impending) pathological fractures. The search contained keywords related to “carbon-fiber” and “fracture” for traumatic fractures, and “carbon-fiber” and “bone tumor” for (impending) pathological fractures (Appendix 1). The following databases were reviewed from database inception up to June 2023: PubMed, MEDLINE, Embase, Web of Science, Cochrane Library, Emcare, Academic Search Premier and Google Scholar.

Eligibility criteria

Eligible study designs included randomized controlled trials (RCTs), cohort studies (with prospective and retrospective designs), case–control studies, cross-sectional studies and case reports. Studies were included if they involved patients with traumatic or (impending) pathological fractures fixated with CF plates. Excluded were meeting abstracts, reviews, editorials, commentaries, surveys, animal-only, in vitro, cadaver or biomechanical studies. No filters or other constraints were used in the database search.

Study selection

After the retrieval of eligible studies, duplicates were removed. Out of the initial pool of 808 traumatic fracture records and 223 oncologic (bone tumour) records, a total of 335 studies on trauma fractures and 116 studies on (impending) pathological fractures remained. Abstracts were obtained and evaluated. Preliminary screening of titles and abstracts led to the exclusion of 311 studies for trauma fractures and 109 studies for (impending) pathological fractures. Subsequently, the full text of 24 studies on trauma fractures were reviewed, and 2 of them were excluded because a more recent third study used the same patient database. Similarly, two of the seven studies concerning (impending) pathological fractures were excluded after full-text screening: one due to irrelevant outcome measurements and one because the same patient had been included in a more recent study (Fig. 1).

Fig. 1
figure 1

PRISMA flow diagram of the study. CF Carbon-fibre

Quality assessment

Methodological quality assessment varied based on the study design. According to the Cochrane Handbook guidelines, the Risk of Bias II (RoB 2) tool was applied for RCTs, the Risk of Bias in Nonrandomized Studies of Intervention (ROBINS-I) tool for non-RCTs, and the Joanna Briggs Institute Checklist for case reports [19,20,21]. With the aid of these tools, various forms of bias were evaluated, including confounding bias, selection bias, bias in classification of intervention, bias due to deviations from intended interventions, bias due to missing data, bias in measurement of outcome and bias in selection of the reported results [19,20,21]. In addition, the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach was utilized to grade quality of evidence, which is important for assessing appropriateness and trustworthiness of recommendations done in the evaluated studies [22]. Within GRADE the following quality of evidence options are possible: high, moderate, low and very low. Randomized trials were initially rated high, observational studies low and other levels of evidence very low. However, high-quality evidence was downgraded if methodological flaws existed, and low-quality evidence could be upgraded when large effect sizes exist. Three reviewers (Z.R., A.W., S.D.) independently assessed the risk of bias for the included studies, discrepancies were discussed and the senior author (M.v.d.S.) was consulted in case of persistent disagreement.

Data extraction

A standard data extraction form was used to collect relevant data from the included studies. The extraction form captured study characteristics (authors, year of publication, country, setting, title, number of included patients and level of evidence), patient characteristics [age, sex, smoking, body mass index (BMI), ASA classification, comorbidities, indication for CF plate fixation and number of patients that received a CF plate], and outcomes (complications, union, clinical, radiological and patient reported outcomes, as well as the duration of follow-up) [23].

Data analysis

To summarize the findings in a quantitative form, complications were subdivided per anatomical region and presented separately for the upper and lower extremities, considering complications might depend on mechanical loading [24, 25]. Descriptive statistics were performed using SPSS v.24 (IBM Corp., Armonk, NY, USA). Demographics of all included studies were shown using medians for continuous variables, as demographic data contained outliers and skewed data due to the inclusion of case reports.

Results

Study characteristics

A total of 22 studies involving 800 patients with trauma fractures (median follow-up 12 months) and 5 studies involving 102 patients (median follow-up 12 months) with (impending) pathological fractures were included in the systematic review. Among them, 11 studies (497 patients, median follow-up 12 months), including three RCTs, compared CF plates with metal plates for trauma fractures (Table 1).

Table 1 Demographics of all included studies (n = 27) for trauma fractures (n = 22), of which 11 were comparative, and (impending) pathological fractures (n = 5)

Study quality

The overall quality assessment score for RCTs, according to RoB 2 tool was “some concerns” for all included RCTs (n = 3; Table 2). The ROBINS-I criteria score for non-comparative studies ranged from low to moderate (n = 19; Table 3), and the mean score for case reports was 6 out of 8 (n = 5; Table 4). Following the GRADE approach, randomized trials were initially rated with a high certainty of evidence. However, due to the risk of bias of the included RCTs, scores were lowered in their certainty of evidence to moderate (Table 5). Observational studies and case reports were rated as with a low or very low certainty of evidence (Table 5). Consequently, recommendations of using CF plates for fixating fractures should be done with caution.

Table 2 Risk of Bias II (RoB 2) tool for RCTs
Table 3 Risk of Bias in Nonrandomized Studies of Intervention (ROBINS-I) tool for non-RCTs
Table 4 Joanna Briggs Institute Critical Appraisal Checklist for Case Reports (n = 5)
Table 5 Reported complications

Reported complications after CF plate fixation for trauma fractures

In the upper extremity, seven studies evaluated CF plate fixation after traumatic proximal humerus fractures, involving a total of 391 patients [16, 26,27,28,29,30,31]. The most frequently reported complications were soft tissue complications (n = 52; 13%), including impingement between plate and acromion (n = 18), rotator cuff lesions (n = 18), adhesive capsulitis/shoulder stiffness (n = 15) and an intra-articular bicep tendon rupture (n = 1). Avascular humeral head necrosis/collapse was also frequently reported (n = 27; 7%). In addition, structural complications were frequently observed (n = 23; 6%), which consisted of secondary screw perforation (n = 12), screws backing out (n = 5), plate breakages (n = 4) and malpositioning of the plate (n = 2). Furthermore, secondary loss of reduction or resorption (> 50%) of tuberosity (n = 17; 4%), varus/valgus malalignment (n = 6; 2%), head shaft malreduction (n = 12; 3%), malreduction of the fracture (n = 3; 1%), nonunions (n = 2; 1%), secondary glenohumeral osteoarthritis (n = 2; 1%) and an infection (n = 1; < 1%) were documented as unfavourable events. Eight studies reported on traumatic distal radius fractures, with a total of 291 patients [10, 32,33,34,35,36,37,38]. Complications for this group included structural complications (n = 6; 2%), soft tissue complications (n = 5; 2%) and an infection (n = 1; < 1%).

Regarding the lower extremity, four studies assessed traumatic femur fracture fixations with CF plates, encompassing a total of 34 patients [39,40,41,42]. Complications observed in this group included one nonunion (n = 1; 3%) and one structural complication (plate breakage, n = 1; 3%). Furthermore, three studies evaluated ankle fractures treated with CF plates [43,44,45], involving 104 patients in total. The most frequently reported complications included infections (n = 4; 4%), soft tissue complication (n = 2; 2%) and one nonunion (n = 1; 1%; Table 5).

Reported complications after CF plate fixation for (impending) pathological fractures

In the upper extremity, two studies evaluated pathological fractures involving 14 humerus and 2 distal radius CF plates [46, 47]. Most frequently reported humerus complications included infections (n = 2; 14%), a structural complication (traumatic plate breakage, n = 1; 7%) and a tumour progression (n = 1; 7%) for which the plate was removed. No complications were reported for the 2 distal radius CF plates.

Regarding the lower extremity, five studies encompassing a total of 86 patients investigated femoral and/or tibial (impending) pathological fractures [46,47,48,49,50]. Complications included structural failures (n = 6; 7%), consisting of plate breakages without clear trauma (n = 2), periprosthetic fractures (n = 2), screw breakage (n = 1) and screw backing out (n = 1). Additionally, documented complications consisted of tumour progressions (n = 5; 6%), infections (n = 4; 5%), nonunion (n = 3; 4%), aseptic loosening (n = 2; 3%), paediatric complications (valgus deformations treated with eight-plates, n = 2; 3%) and a soft tissue complication (wound dehiscence after radiotherapy treatment, n = 1; 2%; Table 5).

Studies comparing CF plates with metal plates

Eleven studies have compared CF plates with metal plates, all focusing on traumatic fractures [26,27,28,29,30, 33, 36, 37, 40, 42, 44]. Among these studies, three were RCTs, and the remaining eight were prospective (n = 4) or retrospective (n = 4) comparative studies. This study hypothesized that CF plates display similar complication rates and clinical outcomes as metal plates for fracture fixation.

In the upper extremity, five studies examined CF plates compared with metal plates for humerus fractures. Firstly, Dey Hazra et al. conducted a retrospective study comparing range of motion after 2 years after fixation using CF plates (n = 30) or titanium plates (n = 35) [30]. The CF group demonstrated significantly improved forward flexion, internal rotation and abduction compared with the titanium group, with similar patient reported outcomes. Secondly, Katthagen et al. prospectively enrolled 21 CF-treated patients and matched them with 21 titanium treated patients [26]. Although functional outcomes were comparable after 12 months, the titanium group required more revisions due to screw perforations (5 versus 0; p = 0.048). Thirdly, Schliemann et al. conducted a prospective study comparing clinical and radiographic results of CF-treated patients (n = 29) to those treated with metal locking plates (n = 29) [28]. After 2 years, patients treated with CF plates achieved significantly better Constant Murley and Oxford Shoulder scores (p = 0.038 and 0.029, respectively), with fewer cases with loss of reduction or varus deformity in the CF group. Fourthly, Padolino et al. conducted a retrospective study comparing clinical and radiographic outcomes of CF-treated patients (n = 21) to those treated with titanium plates (n = 21) [27]. Shoulder mobility, clinical and pain scores were similar in both patient groups after 2 years, while cortical thinning was significantly greater in the CF group (p = 0.0003). Besides, the metal group exhibited a significantly higher rate of tuberosity resorption (p = 0.040). Lastly, Ziegler et al. performed an RCT comparing CF plates (n = 32) with titanium plates (n = 31), but reported no clinical or radiological differences after 6 month’s follow-up [29]. For distal radius fractures, three comparative studies consistently demonstrated similar clinical and radiological outcomes during follow-up evaluations spanning 2 weeks to 3 years [33, 36, 37].

In the lower extremity, two studies evaluated CF and metal plates for distal femur fractures. Mitchell et al. compared CF plates (n = 11) with stainless steel plates (n = 11), observing a trend towards better outcomes in the CF plate group, including less nonunion, less structural failures and less reoperations (9% versus 36%; 0% versus 18%; and 9% versus 36%, respectively) [42]. Byun et al. also compared CF (n = 10) with stainless steel (n = 21), noting better callus formation at 3 months, although this effect diminished at 6 months [40]. Regarding ankle fractures, Guzzini et al. compared CF plates (n = 47) with stainless steel plates (n = 41), reporting no significant differences in terms of pain, radiographic and clinical outcomes at 6-, 12- and 24-month follow-up evaluations [44] (Table 5).

Discussion

As hypothesized, the findings of this systematic review indicate that utilization of CF plates for the fixation of traumatic, and (impending) pathological fractures is associated with a comparable incidence of complications and clinical outcomes to conventional metal plates. CF implants have gained increasing interest due to their potential advantages over metal implants. These advantages include radiolucency, which allows for improved visualization of bone healing and early detection of tumor recurrence, ensuring timely interventions if necessary. The absence of metallic artefacts on radiographic imaging enables more precise postoperative radiotherapy planning. Other advantages include reduced stress shielding which potentially leads to better bone quality, and the absence of cold welding, which facilitates easier removal [1,2,3,4,5,6, 8, 10]. The reported complication data can serve as a valuable benchmark for clinicians and patients, helping manage expectations during CF plate treatment. Although existing evidence suggests CF plates are a viable addition to the surgeons’ armamentarium, quality of current evidence is moderate to weak. Hence, recommendations of utilizing CF plates instead of conventional metal plates should be done with caution.

Adoption of CF plates as standard care for fracture fixation may face challenges due to the well-established use of conventional metal plates and the surgeons’ extensive training and experience with these conventional plates [51]. New technologies are often associated with a learning curve, as performance tends to improve over time [52, 53]. Nevertheless, the surgical procedure in terms of operation time and accuracy of implant position was similar in CF plates compared with metal plates [31, 33]. Moreover, comparable rates of reported complications suggest that implementation of CF plates does not necessitate additional training. Costs of innovations are another important factor for implementation. Although there is a lack of cost-effectiveness studies for CF plates, a recent study comparing CF nails with metal nails showed comparable cost profiles [54]. Yet, long-term evidence on safety and effectiveness needs to be further investigated before adaptation on a large scale is feasible. Rotini et al. and Tarallo et al. both described intraoperative plate breakages at an oval screw hole in the first generation of CF plates [10, 16]. This issue was not reported in more recent studies. Still, one of the drawbacks of CF is the inability to bend the plate to match the patient’s surface anatomy during surgery. Therefore, good preoperative planning is recommended when using these implants. Importantly, patients should be involved in the decision-making and evaluation of implant material, and other osteosynthesis methods, such as intramedullary nailing, should be considered before definitive treatment [55, 56].

Three systematic reviews have previously evaluated CF plates for trauma fracture fixation. Firstly, Saracco et al. included seven studies on distal radius fractures, and reported CF as a potential alternative to conventional metal plates [12]. Secondly, Theivendran et al. evaluated CF fixation in a broader population with small improvements in functional recovery of CF plates after humerus fractures, while there was insufficient evidence to support its widespread use [13]. Thirdly, Choloros et al. (9 studies, 361 patients) states that, considering their high union rates in extremity fracture fixation, CF seems to be a valid alternative to conventional metal plating [11]. Our systematic review (27 studies, 1297 patients), which also included pathological fractures, aligns with these previous results, and reported comparable material specific complications to their metal counterparts. However, high-quality RCTs with long-term follow-up are strongly recommended to provide additional evidence supporting the use of CF plates, their hypothesized advantages and possible contraindications.

Limitations

This systematic review has several limitations. First, its quality is inherently related to the quality of the included studies. Level I or II comparative studies were limited, which represents a major limitation. In general, Level III and IV studies are more prone to selection bias (related to patient selection and/or uncontrolled confounders). The moderate to weak outcomes of the risk of bias assessment and GRADE approach to rate quality of evidence reflected our methodological concerns. However, all studies were still included because we wanted to provide a thorough overview of all available literature. Second, the lack of high-quality studies comparing CF and metal plates was a notable limitation. Especially for (impending) pathological fractures, the absence of comparative studies is a drawback which invites future research. Third, due to the lack of homogenous (comparative) studies and heterogeneity in patient populations, cancer types and complications, a meta-analysis was not performed. Pooling results with data on different complications and types of trauma or cancers would yield results with limited clinical validity. Fourth, there was a lack of clarity between minor and major (complications requiring surgical) interventions, which also limited our reporting about complications. Lastly, most of the included studies only reported short- or midterm follow-up results, which hampers our ability to draw conclusions on the long-term safety and effectiveness of CF plates. Further research is needed to generate high-quality evidence on the long-term safety and effectiveness of CF plates compared with metal plates. Nevertheless, this review provides a comprehensive overview with a complete up-to-date summary on the complication profile of CF plates in traumatic and (impending) pathological fractures.

Conclusion

This systematic review hypothesized that CF plates display similar complication rates and clinical outcomes as metal plates for fracture fixation. Based on the available evidence, this systematic review concludes that CF plates are a viable alternative to metal plates for fracture fixation, without increased material-specific complications. However, more high-quality studies are needed to strengthen the evidence, especially for (impending) pathological fractures. In the meantime, the study’s complication data can serve as a valuable benchmark for clinicians and patients, helping manage expectations during CF plate treatment.