Algorithms and Programs for Express-Analysis of List-Mode Data of Neutron Scattering, Measured on Two-Dimensional Position-Sensitive Detectors with a Delay Line Using Data Acquisition Systems Based on CAEN Digitizers

  • METHODS OF PHYSICAL EXPERIMENT
  • Published:
Physics of Particles and Nuclei Letters Aims and scope Submit manuscript

Abstract

When using general-purpose electronics (in particular, CAEN digitizers) in data acquisition systems from two-dimensional position-sensitive neutron detectors with a delay line, the task of constructing neutron events from raw data must be performed at the software level. Digitizers provide raw data in list mode, often referred to as event-based acquisition mode. A tricky algorithm for constructing neutron events can take too long, which disallows near real-time visualization of measurements. The article presents a way to speed up the operation of algorithms for calculating neutron spectra from raw experimental data measured in the list mode. The developed software for a sufficiently fast conversion of the measured data into formats suited for prompt calculation and visualization the requested positional and time-of-flight spectra of neutrons is described. As a result, it became possible to visualize neutron spectra in near real-time.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.
Fig. 4.
Fig. 5.
Fig.6.
Fig. 7.
Fig. 8.

Similar content being viewed by others

REFERENCES

  1. P. F. Peterson, S. I. Campbell, M. A. Reuter, R. J. Taylor, and J. Zikovsky, “Event-based processing of neutron scattering data,” Nucl. Instrum. Methods Phys. Res., Sect. A 803, 24–28 (2015).

  2. R. I. Smith, S. Hull, M. G. Tucker, H. Y. Playford, D. J. McPhail, S. P. Waller, and S. T. Norberg, “The upgraded Polaris powder diffractometer at the ISIS neutron source,” Rev. Sci. Instrum. 90, 115101 (2019).

  3. G. E. Granroth, K. An, H. L. Smith, P. Whitfield, J. C. Neuefeind, J. Lee, W. Zhou, V. N. Sedov, P. F. Peterson, A. Parizzi, et al., “Event-based processing of neutron scattering data at the Spallation Neutron Source,” J. Appl. Crystallogr. 51 (2018).

  4. C. M. Fancher, C. Hoffmann, V. Sedov, A. Parizzi, W. Zhou, A. J. Schultz, X. P. Wang, and D. Long, “Time filtering of event based neutron scattering data: A pathway to study the dynamic structural responses of materials,” Rev. Sci. Instrum. 89, 092803 (2018).

  5. K. Page, B. Haberl, L. Coates, and M. Tucker, “Preface: Special topic on advances in modern neutron diffraction at Oak Ridge National Laboratory,” Rev. Sci. Instrum. 89, 092601 (2018).

  6. L. Cser, A. Gabriel, M. Kocsis, G. Messing, L. Rosta, and G. Török, “Neutron measurements on the MK 200N-1 type two-dimensional delay-line position-sensitive detector with the new OTDCV1.11 time-to-digital converter,” Phys. B 276278, 216–217 (2000).

    Google Scholar 

  7. F. Descamps, “Resolving pile up with a real-time processor for delay line detectors,” Nucl. Instrum. Methods Phys. Res., Sect. A 508, 440–447 (2003).

  8. C.-H. Lee, Y. Noda, Y. Ishikawa, S. A. Kim, M. Moon, H. Kimura, M. Watanabe, and Y. Dohi, “Development and applications of a new neutron single-crystal diffractometer based on a two-dimensional large-area curved position-sensitive detector,” J. Appl. Crystallogr. 46, 697–708 (2013).

  9. A. Devishvili, K. Zhernenkov, A. J. C. Dennison, B. P. Toperverg, M. Wolff, B. Hjörvarsson, and H. Zabel, “SuperADAM: Upgraded polarized neutron reflectometer at the Institut Laue-Langevin,” Rev. Sci. Instrum. 84, 025112 (2013).

  10. L. Bottyán, D. G. Merkel, B. Nagy, J. Füzi, S. Sajti, L. Deák, G. Endröczi, A. V. Petrenko, and J. Major, “GINA-A polarized neutron reflectometer at the Budapest Neutron Centre,” Rev. Sci. Instrum. 84, 015112 (2013).

  11. S. K. Karaevsky, S. I. Potashev, Y. M. Burmistrov, A. A. Afonin, V. I. Razin, and A. I. Drachev, “Two dimension detectors for thermal and cold neutrons with sizes 120 * 120 mm and 380 * 380 mm with active layer of solid boron-10,” Nauch. Priborostr. 27 (2017).

  12. CAEN N6730. https://www.caen.it/products/n6730/. Accessed Sept. 27, 2021.

  13. S. A. Kulikov and V. I. Prikhodko, “New generation of data acquisition and data storage systems of the IBR-2 reactor spectrometers complex,” Phys. Part. Nucl. 47, 702–710 (2016).

    Article  Google Scholar 

  14. E. I. Litvinenko, A. A. Bogdzel, V. I. Bodnarchuk, Churakov, A. V, Gapon, I. V, V. A. Drozdov, S. A. Kulikov, S. M. Murashkevich, and A. V. Nagornyi, “A comparative analysis of the characteristics of data acquisition systems from position-sensitive neutron detectors,” Instrum. Exp. Tech. 63, 339–347 (2020).

    Article  Google Scholar 

  15. F. V. Levchanovski, B. Gebauer, E. I. Litvinenko, A. S. Nikiforov, V. I. Prikhodko, C. Schulz, and T. Wilpert, “A PCI DAQ board for MWPC detectors with high-rate 2D delay line position readout,” Nucl. Instrum. Methods Phys. Res., Sect. A 529, 413–416 (2004).

  16. F. V. Levchanovskiy and S. M. Murashkevich, “De-Li-DAQ-2D—a new data acquisition system for position-sensitive neutron detectors with delay-line readout,” Phys. Part. Nucl. Lett. 13, 591–594 (2016).

    Article  Google Scholar 

  17. V. A. Andreev, T. A. Gvelesiani, T. I. Glushkova, M. R. Kolkhidashvili, A. G. Krivshich, E. N. Leonova, D. A. Maisuzenko, V. A. Solovei, O. P. Fedorova, and A. A. Fetisov, “Development of a two-dimensional thermal-neutron detector with an entrance window of 600 * 600 mm,” Instrum. Exp. Tech. 63, 626–632 (2020).

  18. Datasheet Mesytec MDLL. https://www.mesytec.com/products/neutron-scattering/MDLL.html. Accessed Sept. 24, 2021.

  19. T. I. Glushkova, V. A. Solovei, V. A. Ulyanov, M. V. Dyachkov, M. R. Kolkhidashvili, T. V. Saveleva, A. A. Sumbatyan, and V. G. Syromyatnikov, “The electronic system of the polarized-neutron reflectometer for the IR-8 reactor,” Instrum. Exp. Tech. 62 (2019).

  20. H. Shishido, Y. Miki, H. Yamaguchi, Y. Iizawa, The V. Dang, K. M. Kojima, T. Koyama, K. Oikawa, M. Harada, S. Miyajima, et al., “High-speed neutron imaging using a current-biased delay-line detector of kinetic inductance,” Phys. Rev. Appl. 10, 044044 (2018).

    Article  ADS  Google Scholar 

  21. S. Skelboe and C. Søgaard, “NMX detector algorithms,” J. Instrum. 14, P02024 (2019). https://doi.org/10.1088/1748-0221/14/02/P02024

  22. CAEN CAEN Digitizer Library. Library of functions for CAEN Digitizers high Level Management. https://www.caen.it/products/caendigitizer-library/. Accessed Oct. 6, 2021.

  23. R. Bayer and E. M. McCreight, “Organization and maintenance of large ordered indexes,” Acta Inform. 1, 173–189 (1972).

  24. I. Antcheva, M. Ballintijn, B. Bellenot, M. Biskup, R. Brun, N. Buncic, P. Canal, D. Casadei, O. Couet, V. Fine, et al., “ROOT – A C++ framework for petabyte data storage, statistical analysis and visualization,” Comput. Phys. Commun. 182, 1384–1385 (2011).

    Article  ADS  Google Scholar 

  25. CAEN DT5810 Fast Digital Detector Emulator. https://www.caen.it/products/dt5810/. Accessed Oct. 4, 2021.

  26. CAEN CoMPASS. Multiparametric DAQ Software for Physics Applications https://www.caen.it/products/ compass/. Accessed Oct. 6, 2021.

  27. A. Kapoulkine, Light-weight, simple and fast XML parser for C++ with XPath support. https://pugixml. org/. Accessed Oct. 6, 2021.

Download references

ACKNOWLEDGMENTS

The authors are grateful to many colleagues and co-authors of our previous publications who took part in obtaining the data at the reactor, which we used in this work to study the performance of the developed software.

The work was carried out with the financial support of the Russian Federation represented by the Ministry of Science and Higher Education, agreement no. 075-10-2021-115 of 13 October 2021 (internal number 15.SIN.21.0021).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to E. I. Litvinenko.

Ethics declarations

The authors declare that they have no conflicts of interest.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Litvinenko, E.I., Bogdzel, A.A. Algorithms and Programs for Express-Analysis of List-Mode Data of Neutron Scattering, Measured on Two-Dimensional Position-Sensitive Detectors with a Delay Line Using Data Acquisition Systems Based on CAEN Digitizers. Phys. Part. Nuclei Lett. 19, 241–248 (2022). https://doi.org/10.1134/S1547477122030128

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S1547477122030128

Keywords:

Navigation