Abstract
Polypyrrole-sepiolite (PPy/SPL) nanofibers were prepared by in situ chemical oxidation polymerization in the presence of sepiolite. A PPy/SPL composite modified glassy carbon electrode (PPy/SPL/GCE) was prepared and characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, and electrochemical methods. Differential pulse anodic stripping voltammetry for the simultaneous determination of trace Pb(II) and Cd(II) was carried out at the PPy/SPL/GCE. Operational parameters such as the deposition potential and time, the amount of modified suspension, and the pH values were optimized for the purpose of determination of trace metal ions in 0.10 M acetate buffer solution. Under the optimal conditions, the stripping peak currents showed good linear relationships with Pb(II) and Cd(II) at concentration ranges of 5.0 × 10–9‒1.2 × 10–6 M and 5.0 × 10–9‒1.2 × 10–7 M, and the detection limits were 1.2 and 1.5 nM, respectively. The proposed method is applicable to the simultaneous determination of trace Pb(II) and Cd(II) in real water samples with the relative standard deviations of less than 4.4% and the recovery rates of 97.9‒102.2%.
Similar content being viewed by others
References
Shams, E. and Torabi, R., Sens. Actuators, B, 2006, vol. 117, no. 1, p. 86.
Zou, Z.W. and Jang, A., MacKnight, E., Wu, P.M., Do, J., Bishop, P.L., and Ahn, C.H., Sens. Actuators, B, 2008, vol. 134, no. 1, p. 18.
Luo, L.Q., Wang, X., Ding, Y.P., Li, Q.X., Jia, J.B., and Deng, D.M., Appl. Clay Sci., 2010, vol. 50, no. 1, p. 154.
Nabid, M.R., Sedghi, R., Bagheri, A., Behbahani, M., and Taghizadeh, M., Abdi Oskooie, H., and Heravi, M.M., J. Hazard. Mater., 2012, vols. 203-204, no. 1, p. 93.
Viguier, B., Zor, K., Kasotakis, E., Mitraki, A., Clausen, C.H., Svendsen, W.E., and Castillo-Leon, J., ACS Appl, Mater. Interfaces, 2011, vol. 3, no. 5, p. 1594.
Milne, A., Landing, W., Bizimis, M., and Morton, P., Anal. Chim. Acta, 2010, vol. 665, no. 2, p. 200.
Lau, O.W. and Ho, S.Y., Anal. Chim. Acta, 1993, vol. 280, no. 2, p. 269.
Jurado, J.M., Martin, M.J., Pablos, F., Moreda-Pineiro, A., and Bermejo-Barrera, P., Food Chem., 2007, vol. 101, no. 3, p. 1296.
Chen, L., Su, Z.H., He, X.H., Liu, Y., Qin, C., Zhou, Y.P., Li, Z., Wang, L.H., Xie, Q.J., and Yao, S.Z., Electrochem. Commun., 2012, vol. 15, no. 1, p. 34.
Li, J., Guo, S.J., Zhai, Y.M., and Wang, E.K., Anal. Chim. Acta, 2009, vol. 649, no. 2, p. 196.
Deng, W.F., Tan, Y.M., Fang, Z.F., Xie, Q.J., Li, Y.Y., Liang, X.L., and Yao, S.Z., Electroanalysis, 2009, vol. 21, no. 22, p. 2477.
Jiang, L., Wang, Y.E., Ding, J.W., Lou, T.T., and Qin, W., Electrochem. Commun., 2010, vol. 12, no. 2, p. 202.
Adraoui, I., Rhazi, M.E., Amine, A., Idrissi, L., Curulli, A., and Palleschi, G., Electroanalysis, 2005, vol. 17, no. 8, p. 685.
Wanekaya, A. and Sadik, O.A., J. Electroanal. Chem., 2002, vol. 537, no. 1, p. 135.
Goubert-Renaudin, S., Moreau, M., Despas, C., Meyer, M., Denat, F., Lebeau, B., and Walcarius, A., Electroanalysis, 2009, vol. 21, no. 15, p. 1731.
Zhao, C.Z., Liu, H., and Wang, L., Anal. Methods, 2012, vol. 4, no. 11, p. 3586.
Wang, J., Acc. Chem. Res., 2002, vol. 35, no. 9, p. 811.
Imisides, M.D., John, R., Riley, P.J., and Wallace, G.G., Electroanalysis, 1991, vol. 3, no. 9, p. 879.
Zanganeh, A.R. and Amini, M.K., Electrochim. Acta, 2007, vol. 52, no. 11, p. 3822.
Zhao, Z.Q., Chen, X., Yang, Q., Liu, J.H., and Huang, X.J., Electrochem. Commun., 2012, vol. 23, no. 1, p. 21.
Wei, Y., Yang, R., Liu, J.H., and Huang, X.J., Electrochim. Acta, 2013, vol. 105, no. 1, p. 218.
Wang, Z.M., Liu, E.J., Gu, D.H., and Wang, Y.S., Thin Solid Films, 2013, vol. 519, no. 15, p. 5280.
Wang, S.R., Kang, Y.F., Wang, L.W., Zhang, H.X., Wang, Y.S., and Wang, Y., Sens. Actuators, B, 2013, vol. 182, no. 1, p. 467.
Zhao, Z.Q., Chen, X., Yang, Q., Liu, J.H., and Huang, X.J., Chem. Commun., 2012, vol. 48, no. 9, p. 2180.
Dogan, M., Turhan, Y., Alkan, M., Namli, H., Turan, P., and Demirbas, O., Desalination, 2008, vol. 230, nos. 1–3, p. 248.
Liang, X.F., Xu, Y.M., Sun, G.H., Wang, L., Sun, Y.B., Sun, Y., and Qin, X., Chem. Eng. J., 2011, vol. 174, no. 2, p. 436.
Marins, J.A., Giulieri, F., Soares, B.G., and Bossis, G., Synth. Met., 2013, vol. 185–186, no. 1, p. 9.
Chen, J., Hong, X.Q., Xie, Q.D., Li, D.K., and Zhang, Q.F., J. Chem. Eng. Data, 2014, vol. 59, no. 7, p. 2275.
Wu, J.H., Li, Q.H., Fan, L.Q., Lan, Z., Li, P.J., Lin, J.M., and Hao, S.C., J. Power Sources, 2008, vol. 181, no. 1, p. 172.
Cho, S.H., Kim, W.Y., Jeong, G.K., and Lee, Y.S., Colloids Surf., A, 2005, vol. 255, no. 1, p. 79.
Crowley, K. and Cassidy, J., Electroanalysis, 2002, vol. 14, nos. 15–16, p. 1077.
Lee, K.P., Gopalan, A.I., and Komathi, S., Sens. Actuators, B, 2009, vol. 141, no. 2, p. 518.
Author information
Authors and Affiliations
Corresponding author
Additional information
The article is published in the original.
Rights and permissions
About this article
Cite this article
Pan, Y., Dong, YP., Chu, XF. et al. High-sensitivity determination of Pb(II) and Cd(II) on a glassy carbon electrode modified with polypyrrole/sepiolite nanofibers. J Anal Chem 72, 682–688 (2017). https://doi.org/10.1134/S1061934817060168
Received:
Revised:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S1061934817060168