Abstract
Planar electrodes based on carbon nanotubes, manufactured by screen printing, are proposed for the determination of anionic surfactants in aqueous solutions. A comparative analysis of the electroanalytical characteristics of planar and solid-state sensors based on various ionophores, namely, ion associates of (1) sodium dodecyl sulfate with a cationic complexes of copper(II) and N,N′-bis(salicylidene)ethylenediamine and (2) sodium dodecyl sulfate with cetylpyridinium, is performed. It is shown that planar electrodes can be used to quantify homologous sodium alkyl sulfates in the concentrations range of 4 × 10−7 (5 × 10−6) to 1 × 10−2 (5 × 10−4) M at pH 4–10 in water bodies and to determine the total concentration of anionic surfactants in detergents.
Similar content being viewed by others
References
Li, M., Li, Y.-T., Li, D.-W., and Long, Y.-T., Anal. Chim. Acta, 2012, vol. 734, p. 31.
Alonso-Lomillo, M.A., Domínguez-Renedo, O., and Arcos-Martínez, M.J., Talanta, 2010, vol. 82, no. 5, p. 1629.
Honeychurch, K.C. and Hart, J.P., TrAC, Trends Anal. Chem., 2003, vol. 22, no. 7, p. 456.
Cummings, E.A., Linquette-Mailley, S., Mailley, P., Cosnier, S., Eggins, B.R., and McAdams, E.T., Talanta, 2001, vol. 55, no. 5, p. 1015.
Shih, Y., Zen, J.-M., Kumar, A.S., and Chen, P.-Y., Talanta, 2004, vol. 62, no. 5, p. 912.
Domínguez-Renedo, O., Alonso-Lomillo, M.A., Recio-Cebrian, P., and Arcos-Martínez, M.J., Sci. Total Environ., 2012, vol. 426, p. 346.
Gonzalo-Ruiz, J., Alonso-Lomillo, M.A., and Munõz, F.J., Biosens. Bioelectron., 2007, vol. 22, no. 7, p. 1517.
Alonso-Lomillo, M.A., Domínguez-Renedo, O., Matos, P., and Arcos-Martínez, J.M., Bioelectrochemistry, 2009, vol. 74, no. 2, p. 306.
Asturias-Arribas, L., Alonso-Lomillo, M.A., Domínguez-Renedo, O., and Arcos-Martínez, M.J., Talanta, 2013, vol. 111, p. 8.
Alonso-Lomillo, M.A., Domínguez-Renedo, O., Ferreira-Gonçalves, L., and Arcos-Martínez, M.J., Biosens. Bioelectron., 2010, vol. 25, no. 6, p. 1333.
Bergamini, M.F., Santos, D.P., and Zanoni, M.V.B., Bioelectrochemistry, 2010, vol. 77, no. 2, p. 133.
Calvo, M.E.B., Domínguez-Renedo, O., and Arcos-Martínez, M.J., Talanta, 2007, vol. 74, no. 1, p. 59.
Domínguez-Renedo, O., Ruiz-Espelt, L., García-Astorgano, N., and Arcos-Martínez, M.J., Talanta, 2008, vol. 76, no. 4, p. 854.
Dontsova, E.A., Zeifman, Y.S., Budashov, I.A., Eremenko, A.V., Kalnov, S.L., and Kurochkin, I.N., Sens. Actuators, B, 2011, vol. 159, no. 1, p. 261.
Yashina, E.I., Borisova, A.V., Karyakina, E.E., Shchegolikhina, O.I., Vagin, M.Y., Sakharov, D.A., Tonevitsky, A.G., and Karyakin, A.A., Anal. Chem., 2010, vol. 82, p. 1601.
Ali, T.A., Mohamed, G.G., El-Dessouky, M.M.I., El-Ella, S.M.A., and Mohamed, R.T.F., J. Solution Chem., 2013, vol. 42, p. 1336.
Ali, T.A., Farag, A.A., and Mohamed, G.G., J. Ind. Eng. Chem., 2014, vol. 20, no. 4, p. 2394.
Shvedene, N.V., Avramenko, O.A., Baulin, V.E., Tomilova, L.G., and Pletnev, I.V., Electroanalysis, 2011, no. 5, p. 1067.
Mohamed, G.G., Ali, T.A., El-Shahat, M.F., Al-Sabagh, A.M., Migahed, M.A., and Khaled, E., Anal. Chim. Acta, 2010, vol. 673, p. 79.
Mohamed, G.G., Ali, T.A., El-Shahat, M.F., Migahed, M.A., and Al-Sabagh, A.M., Drug Test. Anal., 2012, vol. 4, no. 12, p. 1009.
Chernyshov, D.V., Khrenova, M.G., Pletnev, I.V., and Shvedene, N.V., Mendeleev Commun., 2008, vol. 18, no. 2, p. 88.
Brainina, Kh.Z., Alyoshina, L.V., Gerasimova, E.L., Kazakov, Ya.E., Ivanova, A.V., Beykin, Ya.B., Belyaeva, S.V., Usatova, T.I., and Khodos, M.Ya., Electroanalysis, 2009, vol. 21, nos. 3–5, p. 618.
Rzhevskaia, A.V., Shvedene, N.V., and Pletnev, I.V., Sens. Actuators, B, 2014, vol. 93, p. 563.
Lvova, L., Kim, S.S., Legin, A., Vlasov, Y., Yang, J.S., Cha, G.S., and Nam, H., Anal. Chim. Acta, 2002, vol. 468, no. 2, p. 303.
Kulapin, A.I., Chernova, R.K., and Kulapina, E.G., J. Anal. Chem., 2005, vol. 60, no. 5, p. 454.
Kulapina, E.G. and Mikhaleva, N.M., Sens. Actuators, B, 2005, vol. 106, no. 1, p. 271.
Kulapina, E.G., Chernova, R.K., and Kulapin, A.I., Potentsiometricheskie sensory dlya opredeleniya sinteticheskikh poverkhnostno-aktivnykh veshchestv (Potentiometric Sensors for Determining Synthetic Surfactants), Saratov: Nauchnaya kniga, 2008.
Makarova, N.M. and Kulapina, E.G., Zavod. Lab., Diagn. Mater., 2014, vol. 80, no. 6, p. 12.
Author information
Authors and Affiliations
Corresponding author
Additional information
Original Russian Text © N.M. Makarova, E.G. Kulapina, 2015, published in Zhurnal Analiticheskoi Khimii, 2015, Vol. 70, No. 7, pp. 764–769.
Rights and permissions
About this article
Cite this article
Makarova, N.M., Kulapina, E.G. Planar electrodes based on carbon nanotubes for the potentiometric determination of homologous sodium alkyl sulfates. J Anal Chem 70, 879–884 (2015). https://doi.org/10.1134/S1061934815070096
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S1061934815070096