Skip to main content
Log in

Optimization of Analysis Conditions by the Method of Inductively Coupled Plasma Mass Spectrometry with Laser Sampling

  • ANALYSIS OF SUBSTANCES
  • Published:
Inorganic Materials Aims and scope

Abstract

The effect of laser radiation parameters on the sensitivity and relative sensitivity coefficients of element determination in the analysis of various materials by inductively coupled plasma mass spectrometry in combination with laser ablation is studied. It is found that, when the power density of laser radiation is increased above 2 × 1010 W/cm2 for the samples based on silicate glass, basalt glass, and polymetallic sulfides, the laser ablation mechanism changes from thermal to “phase explosion.” It is shown that the coefficients of relative sensitivity of determination of impurity elements with respect to the matrix elements change by no more than 3–5% when the power density varies in the range of 5 × 109–1.5 × 1011 W/cm2. For most impurity elements, the coefficients of the relative sensitivity of determination in different matrices differ by no more than 10–15%, but for a number of elements, a significant difference up to 1.5–2 times is observed. A comparative study of two ablation modes is carried out: when the laser beam is moved along the surface of the sample and during ablation at a “point.” It is shown that the sensitivity of determination of the elements in the first case is 2–3 times higher, while the coefficients of the relative sensitivity of determination are the same for both cases.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.
Fig. 4.
Fig. 5.
Fig. 6.
Fig. 7.

Similar content being viewed by others

REFERENCES

  1. Gray, A.L., Solid sample introduction by laser ablation for inductively coupled plasma source-mass spectrometry, Analyst, 1985, vol. 110, pp. 551–556.

    Article  CAS  Google Scholar 

  2. Zhou, H., Wang, Z., Zhu, Y., et al., Quantitative determination of trace metals in high-purity silicon carbide powder by laser ablation inductively coupled plasma mass spectrometry without binders, Spectrochim. Acta, Part B, 2013, vol. 90, pp. 55–60.

    Article  CAS  Google Scholar 

  3. Bertini, M., Izmer, A., Vanhaeckeb, F., and Kruppac, E.M., Critical evaluation of quantitative methods for the multi-elemental analysis of ancient glasses using laser ablation inductively coupled plasma mass spectrometry, J. Anal. At. Spectrom., 2013, vol. 28, pp. 77–91.

    Article  CAS  Google Scholar 

  4. Möckel, R., Götze, J., Sergeev, S.A., et al., Trace-element analysis by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS): a case study for agates from Nowy Kościoł, Poland, J. Sib. Fed. Univ., Eng. Technol., 2009, vol. 2, no. 2, pp. 123–138.

  5. Sutherland, F.L. and Abduriyim, A., Geographic typing of gem corundum: a test case from Australia, Gemmology, 2009, vol. 31, nos. 5–8, pp. 203–210.

  6. Gonzalez, J., Mao, X.L., Roy, J., et al., Comparison of 193, 213 and 266 nm laser ablation ICP-MS, J. Anal. At. Spectrom., 2002, vol. 17, pp. 1108–1113.

  7. Guillong, M., Horn, I., and Günther, D., A comparison of 266 nm, 213 nm and 193 nm produced from a single solid state Nd:YAG laser for laser ablation ICP-MS, J. Anal. At. Spectrom., 2003, vol. 18, pp. 1224–1230.

    Article  CAS  Google Scholar 

  8. Russo, R.E., Mao, X., Gonzalez, J.J., and Mao, S.S., Femtosecond laser ablation ICP-MS, J. Anal. At. Spectrom., 2002, vol. 17, pp. 1072–1075.

    Article  CAS  Google Scholar 

  9. Fernández, B., Claverie, F., Pécheyran, C., and Donard, O.F.X., Direct analysis of solid samples by fs-LA-ICP-MS, Trends Anal. Chem., 2007, vol. 26, no. 10, pp. 951–966.

  10. D’Abzac, F.X., Seydoux-Guillaume, A.M., Chmeleff, J., et al., In situ characterization of infrared femtosecond laser ablation in geological samples. Part A: the laser induced damage, J. Anal. At. Spectrom., 2012, vol. 27, pp. 99–107.

    Article  Google Scholar 

  11. D’Abzac, F.X., Seydoux-Guillaume, A.M., Chmeleff, J., et al., In situ characterization of infrared femtosecond laser ablation in geological samples. Part B: the laser induced particles, J. Anal. At. Spectrom., 2012, vol. 27, pp. 108–119.

    Article  Google Scholar 

  12. Jochum, K.P., Stoll, B., Weis, U., et al., Non-matrix-matched calibration for the multi-element analysis of geological and environmental samples using 200 nm femtosecond LA-ICP-MS: A comparison with nanosecond lasers, Geostand. Geoanal. Res., 2014, vol. 38, no. 3, pp. 265–292.

    Article  CAS  Google Scholar 

  13. Yoo, J.H., Jeong, S.H., Mao, X.L., et al., Evidence for phase-explosion and generation of large particles during high power nanosecond laser ablation of silicon, Appl. Phys. Lett., 2002, vol. 76, no. 6, pp. 783–785.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to V. K. Karandashev.

Additional information

Translated by Sh. Galyaltdinov

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Khvostikov, V.A., Karandashev, V.K. & Burmii, Z.P. Optimization of Analysis Conditions by the Method of Inductively Coupled Plasma Mass Spectrometry with Laser Sampling. Inorg Mater 54, 1371–1378 (2018). https://doi.org/10.1134/S0020168518140121

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S0020168518140121

Keywords:

Navigation