Abstract
A method for the preparation of a nanocolloidal solution of rhenium sulfide is proposed. It includes the following stages: interaction of ammonium perrhenate and sodium thiosulfate in an aqueous solution of gelatin in an acidic medium with heating to 70–80°C; neutralization to pH 7.0; dialysis against saline; desalination and concentrating by ultrafiltration. The resulting colloidal solution contains 85% of particles with an optimal size of 80–100 nm and can be used as a diagnostic tool for lymphoscintigraphy of sentinel lymph nodes in patients with cancer and other diseases.
Similar content being viewed by others
References
Blakeslee, D.B., Becker, G.D., and Simpson, G.T., Lymphoscintigraphy of the neck. Otolaryngol Head and Neck, Surg. Oncol., 1985, vol. 93, pp. 361–365.
Krag, D.N., Weaver, D.L., Alex, J.C., and Fairbank, J.T., Surgical resection and radiolocalization of the sentinel lymph node in breast cancer using a gamma probe, Surg. Oncol., 1993, vol. 101, pp. 335–339.
Alazraki, N.P., Alazraki, N.P., Styblo, T., Grant, S.F., Cohen, C., Larsen, T., and Aarsvold, J.N., Sentinel node staging of early breast cancer using lymphoscintigraphy and the intraoperative gamma-detecting probe, Semin. Nucl. Med., 2000, vol. 30, pp. 56–64.
Ames, F., Laronga. C., Ross, M., and Alderfer, J., Tumor location and nodal drainage patterns on lymphoscintigraphy are predictors of axillary sentinel lymph node status, J. ASCO, 2001, vol. 20, pp. 40–13.
Romanov, I.S., Odzharova, A.A., Rotin, D.L., and Nechushkin, M.I., Sentinel lymph nodes at squamous cell carcinoma of head and neck, J. Otolaryngology, 2007, no. 6, pp. 14–17.
Kern, K.A. and Rosenberg, R.J., Preoperative lymphoscintigraphy during lymphatic mapping for breast cancer improved sentinel node imaging using subareolar injection of technetium 99m sulfur colloid, J. Am. Coll. Surg., 2000, vol. 191, pp. 479–489.
Lutsevich, E.V., Reshetov, D.N., and Prilepo, Yu.V., Method for diagnostics of metastasis at mammary cancer or melanoma, RF Patent no. 2195871 A61B6/02, 2003.
Tu, W. and Denizot, B., Synthesis of small-sized rhenium sulfide colloidal nanoparticles, J. Coll. Interface Sci., 2007, vol. 310, pp. 167–170. http://www.scirus. com/srsapp/sciruslink?src=mdl&url=http%3A% 2F%2Fwww.ncbi.nlm.nih.gov%2Fentrez%2Fquery. fcgi%3Fcmd%3DRetrieve%26db%3Dpubmed%26dopt% 3DAbstract%261ist_uids%3D 17321536/
Khalkhali, I., Cutrone, J.A., and Mena, I.J., Scintimammography: the complementary role of Tc-99m Sestamibi prone breast imaging for the diagnosis of breast carcinoma, Radiology, 1995, vol. 196, pp. 421–426.
Tsopelas, Ch., 99mTc-labeled and unlabeled antimony trisulfide and rhenium sulfide colloids intended for lymphoscintigraphic application, J. Nucl. Med., 2001, vol. 42, pp. 460–466.
Weiss, M., Kunte, Ch., Schmid, R.A., and Konz, B., Sentinel node mapping in patients with malignant melanoma using melanoma Tc-99m colloidal rhenium sulfide, J. Clin. Nucl. Med., 2003, vol. 28, pp. 379–384.
Manuilov, B.M., Novozhilova, T.I., Mirzabekova, N.S., and Ermakov, A.V., Method for obtaining of colloidal component of diagnostic tool for indirect lymphoscintigraphy, Patent Appl. no. 2014140841/20 (066188) A61B6/02, 09.10.2014.
Mochiki, E., Kuwano, H., Kamiyama, Y., Aihara, R., Nakabayashi, T., and Endo, K., Sentinel lymph node mapping with techneti-um-99m colloidal rhenium sulfide in patients with gastric carcinoma, Amer. J. Surg., 2006, vol. 191, pp. 465–469.
Núñez, E.G.F., Faintuch, B.L., Teodoro, R., Wiecek, D.P., Martinelli, J.R., Da Silva, N.G., Castanheira, C.E., and Pasqualini, R., Influence of colloid particle profile on sentinel lymph node uptake, J. Nucl. Med. Biol., 2009, vol. 36, pp. 1–747. http://www.scirus. com/srsapp/scirus link?src=mdl&url=http%3A%2F% 2Fwww.ncbi.nlm.nih.gov%2Fentrez%2Fquery.fcgi% 3Fcmd%3DRetrieve%26db%3 Dpubmed%26dopt%3 DAbstract%261ist_uids%3D19720286/.
Jimenez, I.R., Roca, M., Vega, E., Garcia, M.L., Benitez, A., and Bajen, M., Particle sizes of colloids to be used in sentinel lymph node radiolocalization, J. Nucl. Med. Commun., 2008, vol. 29, pp. 166–172.
Bensimhon, L., Me’taye, T., Guilhot, J., and Perdrisot, R., Influence of temperature on the radiochemical purity of 99mTc-colloidal rhenium sulfide for use in sentinel node localization, J. Nucl. Med. Commun., 2008, vol. 29, pp. 1015–1020.
Author information
Authors and Affiliations
Corresponding author
Additional information
Original Russian Text © B.M. Manuilov, A.V. Ermakov, 2016, published in Biotekhnologiya, 2016, Vol. 32, No. 3, pp. 78–83.
Rights and permissions
About this article
Cite this article
Manuilov, B.M., Ermakov, A.V. Preparation and Properties of Nanocolloidal Rhenium Sulfide Solution for Lymphoscintigraphic Methods of Micrometastase Examination. Appl Biochem Microbiol 53, 823–826 (2017). https://doi.org/10.1134/S000368381708004X
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S000368381708004X