Introduction

Although endoscopic ultrasound (EUS)-guided tissue acquisition, including fine-needle aspiration (FNA) and fine-needle biopsy (FNB), is a standard modality for establishing a conclusive diagnosis and individualized therapeutic plan for pancreatic solid tumors1, the diagnostic performance has been reported to have a wide range according to the needle type. Several modified novel needles specially designed to obtain histologic cores with intact architecture have been announced recently to overcome these limitations of specific needle types2. These devices, collectively called FNB needles, have been equipped with the unique shape of a needle tip, which has either a side-fenestrated slot (core trap) or a special geometry of the cutting tip, while standard needles without these reinforcement geometries are classified as FNA needles3.

Initially, a new FNB needle with a reversed-bevel system as a side-fenestrated opening on the needle shaft was developed and is currently available as three gauges (19, 22, and 25) in the market. Theoretically, it can obtain the core tissue by hooking, cutting, and trapping it into the needle during the to-and-fro movement. Despite the hypothetical belief that the reversed-bevel design would yield a large piece of core tissue preserving the histological architecture, a special maneuver (e.g., scraping by momentary pulling force) during the to-and-fro movement might be required because it does not have a built-in cutting system2. More recently, the Franseen needle, which has a novel design of a crown tip with three-plane symmetric cutting edges, has been developed to facilitate the acquisition of larger core tissues.

Although recent clinical guidelines3,4 suggested that any specific type of needle, including FNA or FNB needle, does not guarantee superior diagnostic accuracy than others in EUS-guided tissue acquisition for pancreatic solid tumors, FNB needles tend to be customarily used to obtain adequate sampling tissue for differentiation of various tumors by immunohistochemistry (IHC) staining5,6.

Determining the optimal type of needle for accurate diagnosis, especially in the absence of rapid on-site cytological evaluation (ROSE), is critical for EUS-guided tissue acquisition for pancreatic solid tumors; however, there is little conclusive information regarding the relative diagnostic performance through comparison with various types of needles. Therefore, to provide more evidence on this topic, we compared the diagnostic performance according to the type of needle (Franseen needle vs. Reversed-bevel needle vs. standard FNA needle) and determined the variables that affect the diagnostic yield of malignancy of EUS-guided tissue acquisition for pancreatic solid tumors.

Methods

Patients

This was a multicenter retrospective study conducted at Ajou University Hospital, Hallym University Dongtan Sacred Heart Hospital, and Seoul National University Bundang Hospital. Consecutive patients who underwent either EUS-FNB or EUS-FNA for solid pancreatic tumors were included in this study. Patients with only a cystic component in the masses without a solid component suspected of malignant transformation were excluded. Demographic, clinical, and endoscopic data were extracted from a computerized clinical information system for the previous 7 years (from March 2014 to May 2020). Institutional Review Board approval was obtained from Hallym University Dongtan Sacred Heart Hospital (IRB file no: 2021-08-011). Furthermore, all procedures followed have been performed in accordance with the ethical standards laid down in the Declaration of Helsinki. The need for informed consent was waived due to the retrospective nature of this study by the Institutional Review Board of the Ethics Committee of Hallym University Dongtan Sacred Heart Hospital.

Endoscopic procedures for EUS-FNA or FNB

All procedures were performed with a linear array echoendoscope (EG-530UT2, Fujifilm Medical Systems, Tokyo, Japan or UCT 260, Olympus Medical Systems, Tokyo, Japan) by experienced endosonographers (M.J.Y, J.K, and S.W.P) with more than 100 cases of EUS-FNA or FNB per year under a well-established standard protocol7. EUS-FNB was attempted with a biopsy needle (Franseen needle; Acquire; Boston Scientific (Fig. 1A) or Reverse-bevel needle; EchoTip ProCore; Cook Endoscopy (Fig. 1B)) or EUS-FNA with a Menghini-tip needle (EZ shot3, Olympus Medical Systems, Tokyo, Japan (Fig. 1C)) as directed by the characteristics and location of pancreatic tumors and endosonographer’s preference. Furthermore, the size of the needle used (22-gauge or 25-gauge) was chosen at the discretion of the endosonographers. After confirming the absence of intervening vasculature on the expected needle track using the color Doppler, a needle mounted with a stylet was used to create a puncture at either the stomach for body/tail lesions or the duodenum for head/uncinate process lesions. After puncturing the lesion, the stylet was withdrawn, and approximately 10–20 back-and-forth movements were performed within the lesion during each needle passage with continuous suction using a 10–20 mL syringe provided by the manufacturers. Detailly, 10 mL negative suction was applied to the Reverse-bevel needle, while 20 mL negative suction was applied to the EZ shot3 and Franseen needles. In addition, EUS-FNA or FNB was repeated until sufficient visible core tissue was obtained, although the optimal number of needle passes was decided at the discretion of the endosonographers8. ROSE was not available in any institution.

Figure 1
figure 1

(A) The Franseen needle has a novel design of a crown tip with three-plane symmetric cutting edges. (B) The Reverse-bevel needle has a reversed-bevel system as a side-fenestrated opening on the needle shaft. (C) The Menghini-tip needle has a tapered bevel edge that facilitates the tissue being withdrawn into the lumen. Although it has a side port, it is classified as FNA needles because the side port of this needle system does not have any reinforcement geometries for cutting the tissue.

Cytopathological analysis using each FNB needle

In this study, cytological and histological evaluations were performed by a single cytopathologist experienced in pancreatology at each institution. The samples obtained from each passage by advancing the stylet within the needle assembly were fixed entirely into 50% ethanol for cell block evaluation and formalin bottles for histologic evaluation9. The prepared histological samples fixed in formalin solutions were re-processed in cassette form, embedded in paraffin, and prepared in hematoxylin and eosin (H & E) stain for evaluation by the same pathologist. When necessary, special staining such as IHC staining was applied to differentiate between tumor cells and regenerative atypia or atypical tumors such as lymphoma, metastatic carcinoma, solid pseudopapillary tumors, or even neuroendocrine tumors. If a histological core was not obtained, the cytopathologist processed the same material as the cell block for cytological analysis.

Definition of outcomes and reference criteria for the diagnosis of benign or malignant pancreatic masses

The primary outcome of this study was the diagnostic performance of the needles. The secondary outcomes were defined as the procurement rates of histologic cores considered to be of optimal quality for histological evaluation according to the needles used for the EUS-FNB procedure, procedure-related adverse events, and variables that affected the diagnostic accuracy in a logistic regression model. In detail, sufficient visible core tissue was defined as whitish or reddish pieces of tissue with apparent bulk on the filter paper or slide glass10.

A final diagnosis was established as either a malignant or benign mass based on one of the following reference criteria: (a) a definite diagnosis based on the evaluation of surgically resected permanent specimens from operated patients, (b) disease-specific mortality, and (c) no evidence of disease regression or progression during the longer than 6-month follow-up periods according to clinical and radiological workups only in cases of suspected benign disease at the time of the EUS-FNB7,11,12. In the initial categorization as definite or suspected malignancy based on cell block or histologic analysis by EUS-FNA or FNB, cases confirmed as malignancy in the final diagnosis were considered as true positives, while lesions that were finally diagnosed as benign diseases after the clinical follow-up were considered false positives. Similarly, if the initial benign results were finally diagnosed as benign diseases, they were considered as true negatives, while those confirmed as malignancies in the final diagnosis were considered as false negatives. Furthermore, non-diagnostic results, including insufficient samples, were considered false negatives because the procedure failed to provide a diagnosis13.

Statistical analysis

Continuous variables were presented as mean and standard deviation and were compared using Student’s t-test. Categorical variables were presented as numbers (percentages) and were compared using the χ2 test. Univariate and multivariate logistic regression models were applied to assess the relationship between clinical and endoscopic variables, including needle type, with an accurate diagnosis. The variables found to be significant (P < 0.20) in the univariate model were entered into the multivariate logistic regression model. The diagnostic sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) were evaluated for all needle types. All reported P-values were two-sided, and P-values < 0.05 were considered statistically significant. All statistical analyses were conducted using the statistical software R (version 3.3.3; R Foundation for Statistical Computing, Vienna, Austria).

Results

Study population and baseline characteristics

During the study period, 828 patients underwent EUS-FNB for solid pancreatic tumors (Fig. 2). Patients with anatomical alterations, which made it impossible to deliver an echoendoscope (n = 21), those who had significant gastric outlet obstruction (n = 12), those who had collateral intervening vessels, which made it impossible to puncture with a needle (n = 9), and those with pure cystic lesions without a solid component that was only possible for aspiration and not tissue acquisition (n = 117) were excluded. Overall, 669 patients were included in the analyses and divided into three groups: Franseen (n = 196), Menghini-tip (n = 113), and Reverse-bevel (n = 360).

Figure 2
figure 2

Flow diagram of patients throughout the study.

Table 1 presents the baseline characteristics of the patients according to each group. The mean age of the Franseen group was significantly higher than that of other groups (Franseen vs. Menghini-tip vs. Reverse-bevel group: 66.3 ± 12.0 vs. 62.5 ± 15.2 vs. 65.0 ± 12.0, respectively; P = 0.039). The proportion of male patients and body mass index did not differ between the groups. Additionally, a 22-gauge needle was predominantly used in the Franseen and Menghini-tip groups, while the 25-gauge needle was used frequently in the Reverse-bevel group with a significant difference (P < 0.001). In the three groups, a suspected malignant mass was the most common indication for EUS-FNA/B, with a significant difference (P = 0.008). The mass was most frequently located in the pancreatic head (39.3%, 45.1%, and 51.9% in the Franseen, Menghini-tip, and Reverse-bevel groups, respectively) with significant intergroup differences. The mean size of the lesion was 30.3 mm in the Franseen group, 36.3 mm in the Menghini-tip group, and 29.9 mm in the Reverse-bevel group, with significant intergroup differences.

Table 1 Characteristics of patients.

Procedure-related findings between the three groups

Procedure-related outcomes are presented in Table 2. The transduodenal approach was greater than the transgastric approach in all three groups because the most common location of the lesions was the head in all groups. Moreover, the number of needle passes was higher in the Reverse-bevel group than in the two other groups (Franseen vs. Menghini-tip vs. Reverse-bevel group: 2.8 ± 1.0 vs. 2.9 ± 0.5 vs. 3.4 ± 1.3, P < 0.001). Continuous suction with negative pressure using a syringe was applied during EUS-FNA/B for all patients in the three groups. The Fanning technique was applied to all patients in the Franseen group, while it was performed for only 53.1% of patients in the Menghini-tip group and 82.2% of patients in the Reverse-bevel group (P < 0.001) with significant intergroup differences.

Table 2 Comparison of procedure-related outcomes between the three groups.

No technical difficulties were encountered in either group, even when transduodenal passes were performed. Regarding procedure-related adverse events, only eight patients (8/669, 1.2%) in the entire cohort had immediate bleeding as an adverse event, and all patients in each group were managed by clipping several times on the same endoscopic session. In addition, only five patients developed mild acute pancreatitis that required hospitalization within 3 days (1.5% in the Franseen group and 0.6% in the Reverse-bevel group, P = 0.266). No patient in each group experienced significantly delayed bleeding or infectious adverse events. Histological core tissue was significantly higher in the Franseen than Menghini-tip and Revers-bevel groups (Franseen vs. Menghini-tip vs. Reverse-bevel group: 98.0% vs. 85.8% vs. 91.9%, P < 0.001). Furthermore, core biopsy specimens that were adequate for IHC analysis were obtained in 95.4% of cases using the Franseen needle, 65.5% for the Menghini-tip needle, and 88.3% for the Reverse-bevel needle (P < 0.001). The most common final diagnosis in the three groups was ductal adenocarcinoma.

Diagnostic performance of each needle for EUS-FNA/B

Diagnostic performance was calculated in two different ways using the methods of specimen processing. On the initial diagnosis by cell block evaluation, the Franseen needle had 86.09% sensitivity, 100.0% specificity, a PPV of 100%, and an NPV of 57.89%, while the Menghini-tip needle had 55.71% sensitivity, 100.0% specificity, a PPV of 100.0%, and an NPV of 54.41% (Table 3). In addition, the Reverse-bevel needle had 71.98% sensitivity, 100.0% specificity, a PPV of 100%, and an NPV of 39.50%. Moreover, the diagnostic accuracies for the Franseen, Menghini-tip, and Reverse-bevel needles were 88.32%, 71.03%, and 76.32%, respectively. On the initial diagnosis by histologic evaluation, the Franseen needle provided improved diagnostic performance (95.03% sensitivity, 100.0% specificity, a PPV of 100.0%, and an NPV of 81.40%) with an accuracy of 95.92%; the Menghini-tip needle provided diagnostic performance (82.67% sensitivity, 100.0% specificity, a PPV of 100.0%. and an NPV of 74.51%) with an accuracy of 88.50%; while the Reverse-bevel needle showed a diagnostic performance (82.61% sensitivity, 100.0% specificity, a PPV of 100.0%, and an NPV of 53.98%) with an accuracy of 85.56%.

Table 3 Diagnostic performance according to the needles.

In direct comparison of diagnostic performances using histologic samples between the needles, the Franseen needle showed significantly superior sensitivity than the Menghini-tip (P = 0.003) and Reverse-bevel needles (P < 0.001) (Fig. 3). Furthermore, the Franseen needle also showed significantly superior accuracy than the Menghini-tip (P = 0.018) and Reverse-bevel needles (P < 0.001).

Figure 3
figure 3

Comparison of diagnostic performance according to the needles.

Variables associated with diagnostic accuracy

Univariate and multivariate analyses were performed using logistic regression models to identify the factors associated with diagnostic accuracy (Table 4). Tumor size > 2 cm (odds ratio [OR]: 5.36, 95% confidence interval [CI]: 3.40–8.47) and the application of the fanning technique (OR: 1.70, 95% CI: 1.00–2.86) were significantly associated with an accurate diagnosis in the multivariable analysis. Furthermore, the Menghini-tip needle was identified as an associate variable for poor accurate diagnosis (OR: 0.54, 95% CI: 0.29–1.00, P = 0.050) with marginal significance. Furthermore, FNB needles, including Franseen and Reverse-bevel needles, were significantly associated with accurate diagnosis compared to FNA needles (Menghini-tip needle) (OR: 2.03, 95% CI: 1.21–3.38, P = 0.007) (Table S1).

Table 4 Variables for accurate diagnosis according to logistic regression models.

Discussion

According to the development and improvement of new types of needles for EUS-FNA/B, many trials2,14,15,16,17,18,19 revealed that modified needles with reinforcement geometries on the tip provided superior diagnostic accuracy and histological core tissue procurement for pancreatic solid tumors. Our study is the first report that compared the three types of needles (Franseen needle, Reverse-bevel needle, and Menghini-tip needle) for adequacy and accuracy of samples from each needle. In our retrospective comparative study, EUS-FNB using a Franseen needle was associated with a higher procurement rate of histologic core tissue than Reverse-bevel needles and even Menghini-tip needles. Furthermore, the Franseen needle showed overwhelmingly improved diagnostic performance, including 95% sensitivity, 96% accuracy, and 81.4% NPV compared to other needle types. In the first preliminary report for Franseen needle, Bang et al. demonstrated that a unique crown tip with three-plane symmetrical cutting edges enables better targeting of lesions with lower penetration force and even greater tissue acquisition20. Thereafter, they prospectively compared the cellularity and diagnostic accuracy of four types of needles, including the Franseen, Reverse-bevel, and Menghini-tip needles21. In this study, the authors concluded that the Franseen needle showed the highest degree of cellularity for pancreatic solid tumors, although the number of patients assigned to each group was as relatively small as 32–33 patients. Furthermore, the Franseen needle showed the highest diagnostic accuracy of 92.7%, while those of the Menghini-tip and Reverse-bevel needles were 74.7% and 67.7%, respectively. These results were entirely consistent with our results and our hypothesis that the pathological outcomes of EUS-FNA/FNB are totally dependent on the type of needle used for tissue sampling.

Notably, the fanning technique was an independent favoring factor for accurate diagnosis, although an initial study by Bang et al. failed to verify the significant impact of the technique on diagnostic performance22. Recent clinical guideline strongly suggests that the fanning technique for EUS-guided tissue acquisition offers technically acceptable feasibility and superior diagnostic outcomes, including fewer needle passes required to establish a definite diagnosis than the standard technique3. Thus, our study reinforces the need for the fanning technique for routine application for EUS-FNA/FNB from clinical guidelines: the fanning technique increases diagnostic accuracy. Theoretically, the application of the fanning technique can increase the likelihood of achieving an accurate diagnosis, thereby reducing the possibility of inconclusive results without additional risk of adverse events or medical costs.

Our study has several valuable implications. First, EUS-FNA/FNB using a Franseen needle might reduce the need for ROSE because its sensitivity and diagnostic accuracy for malignancy by histologic evaluation exceeded 95% without ROSE in all cases. Although ROSE provides a high per-case adequacy of a sample with fewer number of needle passes23, recent observational data have reported conflicting results, in which ROSE may not be associated with an improvement in diagnostic yield, including accuracy and sensitivity24. Second, optimal histologic core tissue, which can be achieved for special staining such as IHC, was obtained in 95% of the Franseen needle. Acquiring reliable and sufficient tissue can provide preserved histologic architecture for special staining and even molecular profiling, which is essential for the differential diagnosis of other pancreatic tumors or inflammatory masses and personalized anti-cancer therapy25. Third, although recent guidelines3 recommended that a minimum of four passes is required to achieve an accurate diagnosis and more than four passes may be required for tumors less than 2 cm, in our study, superior diagnostic performance was achieved with fewer passes using a Franseen needle than Reverse-bevel or Menghini-tip needles. Therefore, in institutions relying on the Reverse-bevel and Menghini-tip needles, we carefully recommend conducting three or four passes to achieve an accurate diagnosis.

Although our study is the first to evaluate the diagnostic performance of the three types of needles for EUS-FNA/B in a large cohort, it had some limitations that might have influenced our final conclusions. First, several technical biases, including the application of suction, stylet, or fanning methods, could not be completely avoided because of the retrospective nature of the study. In addition, retrospective data analysis may lack some information about important variables (information bias). Although we adjusted for potentially confounding variables, including needle type, needle diameter, tumor size, approaching route, number of needle passes, and hidden or unmeasured factors may have remained. Therefore, this study still has important limitations. We hope that this limitation can be overcome through randomized controlled trials. Second, the cytopathologic results were determined by a single pathologist at each center, which may have introduced observer bias with inter- and intra-observer variations. Third, our methodology for defining benign diseases has not been validated. Nevertheless, to avoid unnecessary surgery, our strategy, including clinical follow-up of ≥ 6 months with repeated workups, was relatively reasonable for defining benign disease, although admittedly, not ideal. Fourth, there might have been heterogeneity between the present study and many other studies regarding the definition of malignancy in which “highly suggestive” samples could be generally considered diagnostic and acceptable26. However, there might have been a discrepancy in diagnostic performance if highly suggestive samples were categorized as diagnostic of malignancy or not.

In conclusion, to establish the optimal needle and technique that can yield an accurate diagnosis, we believe that our suggestions of using the Franseen needle under the fanning technique may enable standardization of the practice of EUS-guided tissue acquisition in pancreatic cancer. Furthermore, FNB needles with any reinforcement geometries, instead of standard FNA needles, can be recommended regardless of the model and manufacturer of needles.