Abstract
Transcriptome profiling of human whole blood is used to discover biomarkers of diseases and to assess phenotypic traits. Recently, finger-stick blood collection systems have allowed a less invasive and quicker collection of peripheral blood. Such non-invasive sampling of small volumes of blood offers practical advantages. The quality of gene expression data is strictly dependent on the steps used for the sample collection, extraction, preparation and sequencing. Here we have: (i) compared the manual and automated RNA extraction of small volumes of blood using the Tempus Spin RNA isolation kit and the MagMAX for Stabilized Blood RNA Isolation kit , respectively; and (ii) assessed the effect of TURBO DNA Free treatment on the transcriptomic data of RNA isolated from small volumes of blood. We have used the QuantSeq 3′ FWD mRNA-Seq Library Prep kit to prepare RNA-seq libraries, which were sequenced on the Illumina NextSeq 500 system. The samples isolated manually displayed a higher variability in the transcriptomic data as compared to the other samples. The TURBO DNA Free treatment affected the RNA samples negatively, decreasing the RNA yield and reducing the quality and reproducibility of the transcriptomic data. We conclude that automated extraction systems should be preferred over manual extraction systems for data consistency, and that the TURBO DNA Free treatment should be avoided when working on RNA samples isolated manually from small volumes of blood.
Similar content being viewed by others
Introduction
Transcriptome profiling is a reference research field, and it is applied especially for the study of human diseases1,2. The analysis of the human transcriptome allows us to understand the human genome at the gene expression level and also provides a window to understand gene regulation and genome plasticity2,3,4. However, gene expression profiling can only be of value when the RNA under study is representative of the starting material5. Unfortunately, several pre-analytical factors affect the RNA yield and quality and might hamper the representativeness of the starting RNA5, including RNA isolation methods, DNase treatments, library preparation etc. The ex vivo instability of RNA can be reduced if the blood is freshly extracted and processed for RNA isolation immediately. However, this is not a feasible option and, in most cases, blood is collected with variations in timing and storage conditions, which have been proven to affect transcriptomic profiles to some degree6. Different RNA stabilizers are employed to overcome the limitation of using fresh blood for RNA isolation7,8,9. Such stabilizer solutions immediately lyse cells chemically and stabilize nucleic acids. Cellular RNases are inactivated, and the RNA is selectively precipitated, leaving proteins and genomic DNA in solution. One of the most common RNA stabilizer solutions is represented by Tempus Blood RNA (Thermo Fisher Scientific, MA, USA). Tempus system uses a solid-phase, silica-based isolation strategy and its performance has been proven higher than other systems10. Yet, Tempus Blood RNA utility is limited by the requirement of a venous blood samples of at least 3.0 ml. Recently, finger-stick blood collection systems have made it possible to collect peripheral blood without the need of medical infrastructures, offering practical and logistic advantages11. Nevertheless, technical improvements are required to make the gene expression profiling of small volumes of blood a reliable and reproducible technique12. Automated workflows offer several advantages for large-scale projects, as they increase sample throughput and reduce cost and manual errors13,14,15,16. The MagMAX for Stabilized Blood RNA Isolation kit (Thermo Fisher Scientific, MA, USA) employs a magnetic bead-based technology to purify RNA from blood stored in Tempus solution. Because of its bead-based approach, it can easily be implemented on automated systems. The MagMax workflow includes a TURBO DNase step that removes contaminating DNA and can also be implemented in automation systems, such as the KingFisher Magnetic Particle Processors (Thermo Fisher Scientific, MA, USA). However, there currently exist many liquid-handling workstations on the market, each one of them offers different degrees of flexibility. Hamilton Robotics (Hamilton, NV, USA), for instance, offers autonomous programming15. In this study the Hamilton NGS Star platform has been employed for automated RNA extraction.
Here, we have compared the manual RNA isolation of small volumes of blood (Tempus Blood RNA kit) and an automated workflow implemented in-house by using the MagMAX for Stabilized Blood RNA Isolation kit on the Hamilton NGS Star platform (Hamilton, NV, USA); we have also evaluated the effect of the TURBO DNA Free treatment (Thermo Fisher Scientific, MA, USA) on the reproducibility and reliability of the transcriptomic data. Transcriptome sequencing was performed by using the Lexogen QuantSeq 3′ mRNA-Seq Library Prep FWD kit (Lexogen GmbH, Austria) with unique molecular identifiers (UMI), because of its streamlined protocol and its relatively lower cost as compared to other systems.
Here we demonstrate that the automated extraction workflow produces more consistent data as compared to the manual extraction method and that the TURBO DNA Free treatment should be avoided when working on RNA isolated manually from small volumes of blood.
Methods
RNA isolation
Whole blood was collected from healthy donors as previously described11. Ethical approvals were collected from Sidra Institutional Review Board committee (IRB Protocol #1707011887). An informed consent was obtained from the study subjects and all methods were performed in accordance with the relevant guidelines and regulations. Different conditions were tested for each healthy donor recruited, as shown in Fig. 1. For the manual process, the Tempus Spin RNA Isolation kit was used to isolate and purify RNA from blood collected in the capillary tubes according to the manufacturer’s instructions and adjusting the reagents volumes to maintain the working ratios required by the protocol. For the automated process, the MagMAX for Stabilized Blood RNA Isolation kit was used on the Hamilton NGS Star platform using a protocol developed in-house. The protocol developed in house includes some initial manual steps. Figure 2 summarizes the manual and automated steps of the protocol developed in-house with the MagMAX for Stabilized Blood RNA Isolation kit . Supplementary Fig. 1 displays the deck layout of the Hamilton NGS STAR. The MagMAX for Stabilized Blood RNA Isolation kit uses a magnetic bead-based technology and includes a DNase treatment step (TURBO DNA Free treatment). After extraction, RNA was quantified on the NanoDrop 8000 Spectrophotometer (Thermo Fisher Scientific, MA, USA) to evaluate the concentration and purity. The amount of RNA present in each sample was then detected on the Qubit 2.0 Fluorometer (Thermo Fisher Scientific, MA, USA) using the Qubit RNA HS Assay kit (Thermo Fisher Scientific, MA, USA). The RNA profile and integrity of all samples was assessed using the RNA Assay Reagent kit on the LabChip GXII (PerkinElmer, MA, USA). Samples were evaluated according to their RIN (RNA integrity number). This score is classified on a numbering system from 1 to 10, with 1 indicating the most degraded RNA and 10 indicating the most intact RNA.
Lexogen QuantSeq 3′ mRNA-Seq
Lexogen QuantSeq3′ mRNA-Seq libraries for Illumina sequencing were prepared from 120 ng of total RNA according to the manufacturer’s recommendations.
The first strand was synthesized by reverse transcription with oligo-dT priming followed by treatment with The Globin Block (RS-GB) Module for QuantSeq. The RS-GB solution has specific oligos which selectively bind to the globin mRNA cDNA-transcripts and prevent the generation of library fragments from globin mRNAs, by blocking their extension during second strand synthesis, initiated by random priming. Because the globin blocking oligo is bound close to the poly-(T)-section of the first strand, the second strand synthesis stops for globin transcripts and does not reach the 5′ sequencing tag of the first strand, thus yielding non-amplifiable globin cDNAs. The non-globin tagged double-stranded cDNA library fragments were then amplified for 18 PCR cycles and labelled with different single indices. The UMI Second Strand Synthesis Mix (USS) containing Unique Molecular Identifiers (UMIs) was used during second strand synthesis prior to PCR. UMIs act as tags that allow detection and removal of PCR duplicates in sequencing data.
The quality and size of the libraries were determined using the NGS 3K assay on the Labchip GXII and pooled based on quantification via qPCR using the KAPA HiFi Library quantification kit on the LightCycler 480 II (Roche Diagnostics, Basel, Switzerland). Libraries were pooled on the Hamilton MicroLab Star and sequenced on the Illumina NextSeq 500 system at a depth of 8 million reads per library. Out of the 60 samples, 48 samples were sequenced using the High Output 75 cycles kit and single end read mode and 12 samples were sequenced using the High Output 150 cycles kit and single end read mode (Supplementary Table 1). The QC of sequencing data was performed as recommended by Illumina.
Data analysis
The preliminary quality of sequencing reads was assessed using FASTQC (v.0.11.8). We have used the recommended QuantSeq FWD-UMI Data Analysis Pipeline which is specific for Quantseq FWD libraries that contain UMIs. First, the umi2index process adds the 6 nucleotide UMI sequence to the identifier of each read and trims the UMI from the start of each read; the FASTQ file generated at this step was processed through trimming and alignment. Quality trimming was performed to remove the adapter sequences and polyA tails using bbduk.sh from BBMap (v38.69). Per base sequence quality plots showing average quality scores above 30 for raw fastq and the quality trimmed fastq is reported in Supplementary Fig. 3. Trimmed reads were mapped to the human genome GRCh38.p13 (Genome Reference Consortium Human Build 38, INSDC Assembly GCA_000001405.28, Dec 2013) using STAR_2.6.1d aligner and HTSeq-count (v0.9.1) was used to generate the raw counts. The reads of the samples sequenced at 150 nt were trimmed to the first 75 nt. As per Lexogen recommendations, sequencing at 150 nt and trimming to the first 75 nt gives the same results as sequencing at 75 nt. The RSeQC distribution was similar for the untrimmed and trimmed reads (Supplementary Fig. 2).
Normalized data was transformed using variance-stabilizing transform (VST) and removed batch effect using limma::removeBatchEffect from Lima package (v3.48.2). The RSeQC (v3.0.1) geneBody_coverage2.py and the RSeQC’s read_distribution.py modules were used to calculate the RNA-seq reads coverage over the gene body and the distribution of mapped reads across genomic features, respectively. Heatmaps, correlation matrices and PCA plots were generated as relevant by using R packages.
A simulation analysis was performed using RSEM (v1.2.25). Reads of 75 nt were simulated to different depths, namely: 50 M, 100 M, and 400 M reads using rsem-simulate-reads. This program took estimated_model_file and estimated_isoform_results as input which were learned from real data using rsem-calculate-expression program. Simulated reads were analyzed in the same way as for the real data (aligned and quantified using STAR (v2.1.6_d) and HTSeq-count (0.9.1) tools followed by DeSeq2 VST normalization and generate QC plots).
Non-parametric Wilcoxon signed-ranks and Mann–Whitney tests were applied to compare groups as appropriate. Non-parametric Spearman r test was used to evaluate correlations. All statistical tests were two-sided. p-values lower than 0.05 were considered statistically significant.
Results
RNA quality and quantity
Samples were divided into 6 groups, according to their (i) extraction method (manual vs automated); (ii) TURBO DNA Free treatment (treated vs untreated), and iii. starting volume of whole blood (16 μl, 33 μl, 50 μl and 66 μl). The elution volume was 50 μl for all the extractions performed. Thus, we have used the Qubit (fluorescence-based) concentration values (ng/μl) for comparative analysis. As expected, the RNA concentration increased parallelly to the increased volume of blood used for the extraction, with the concentration obtained from 66 μl of blood being significantly higher as compared to the concentration obtained from 16 μl of blood (Wilcoxon matched-pairs signed-ranks test, p = 0.0039, Fig. 3A, Table 1). Interestingly, the variability (measured by the standard deviation) increased parallelly to the amount of whole blood used for the extraction (Fig. 3A, Table 1), suggesting that the sampling might give more consistent results for lower volumes of blood.
When using 50 μl of blood, we found a significant decrease of the RNA concentration in the manual TURBO-treated protocol and the automated TURBO-treated protocol as compared to the manual untreated protocol (Wilcoxon matched-pairs signed-ranks test, p = 0.0010 and p = 0.0129, respectively, Fig. 3B). While the RNA concentration values correlated significantly for the manual treated and untreated protocols (Spearman r test, p = 0.001) we found no significant correlation between the manual and automated protocols that included the TURBO DNA Free treatment, suggesting that workflow-specific steps might affect the RNA concentration more than the TURBO DNA Free treatment and biological variables (i.e. individual cell counts, Fig. 3C,D).
Overall, all the RNA isolated was of good quality. No significant difference in RIN value was observed across samples processed from different volumes of starting material (Fig. 3E). Nevertheless, the RIN values obtained from the different samples varied across the experimental groups with the manual extraction method producing overall higher RIN values as compared to the automated methods (Fig. 3F, Table 1).
The A260/A230 values varied across the experimental groups with the automated TURBO-treated samples of 16 μl blood producing the lowest A260/A230 ratio (0.63 ± 0.29). The A260/A280 values were > 2 for all the experimental groups except for the manual TURBO-treated 50 μl blood samples that displayed an average A260/A280 ratio of 1.31 ± 0.09.
We next sought to assess the effect of TURBO DNA Free treatment on the RNA yield and RIN values. For the manual protocol the TURBO DNA Free treatment resulted in an overall yield reduction > 25% (Table 2), while the RIN values increased slightly (Table 2). When we compared the yield and RIN values in the automated TURBO DNA Free protocol to the manual untreated protocol, we found a yield reduction similar to the one induced by the TURBO DNA Free treatment in the manual protocol (Table 3). However, the TURBO DNA Free treatment induced a RIN reduction between 3.36–11.51% in the automated protocol as compared to the manual untreated protocol (Table 3).
Gene expression analyses
We assessed the reproducibility of gene expression profiles obtained from the different RNA extraction methods. Out of the 60 samples, 2 samples extracted manually from the same donor generated a library of a size and concentration deviating from what is recommended for Lexogen Quant-Seq 3′mRNA-Seq Library Prep and were removed from the downstream processing. This could be due to the low purity of the samples as their Nanodrop readings demonstrated a high A260/A230 ratio. Two additional samples produced libraries of suboptimal molarity and were labeled as “low conc. library” for further analyses. After sequencing and read mapping, we have evaluated the alignment scores, the count assignments and read distribution across the samples. Because in the Lexogen Quant-Seq 3′mRNA-Seq Library Prep method cDNA molecules are transcribed from the 3′ end of the mRNAs, the reads preferentially mapped to the 3′ end of the transcript. Samples processed manually had a slightly higher percentage of reads mapping to exonic region, however the samples showed overall consistent body coverage, alignment scores and gene type assignment profiles (Supplementary Fig. 4).
When we looked at the distribution of the VST counts across the sample set, we noticed an overall homogeneous distribution of the VST counts, however the samples processed manually showed a higher variability of the VST counts as compared to the samples processed with the automated method (Fig. 4A). The simulation analysis yielded similar read distribution over gene body elements and gene types across the methods, although the read distribution was more consistent for the samples processed with the automated method (Supplementary Figs. 5 and 6).
To explore the effect of the different variables assessed in the study on the complete transcriptomic data we have used principal component analysis (PCA).
The assignment of the samples to the three individuals accurately predicted their distribution in a three-dimensional space suggesting that their transcriptional signatures can be retraced to the individual biology (Fig. 4B). Contrarily, the different extraction methods and the DNase treatment seemed to have a negligible effect on the sample distribution (Fig. 4C), although samples processed manually displayed a higher variability. This might be explained by the fact that biological variables might have a larger effect on the transcriptomic data as compared to analytical variables (i.e., isolation method, DNase treatment). Similar findings were obtained with the simulation analysis (Supplementary Fig. 7). It should be noted that in the PCA plots displayed in Fig. 4B,C, the variance of PC1 was 45%, indicating that the transcriptomic data of the samples was overall quite similar.
Nevertheless, the correlation matrix identified an overall high degree of similarity across the samples isolated with the automation method as compared to the ones isolated manually, irrespective to starting blood volume and DNase treatment (Fig. 5A). When performing correlation analysis only on the samples isolated on the automated system, we found an almost perfect correlation of samples belonging to the same individual, irrespective to the starting blood volume (Fig. 5B), supporting the sampling of volumes of blood as low as 16 μl as an efficient method for whole blood transcriptomic profiling.
Processing time/sample throughput comparison between the manual and automated workflow
We have also evaluated the processing time of the standard manual extraction protocol and the automated protocol developed in-house on the Hamilton NGS Star platform.
The manual workflow overall takes about 75 min hands-on-time and 65 min incubation time, while the automated workflow overall takes 20 min hands-on-time and 50 min incubation time. The above calculations refer to the processing of a batch of 24 samples. However, the sample throughput can be significantly increased in the automated workflow as the Hamilton NGS STAR system is equipped with 3 × 32 sample tube carriers and it can process 96 samples per batch. Additionally, faster bead clean-up steps can be adopted to this method if the liquid handler is equipped with 96-Multi Probe Head.
Discussion
Transcriptomic profiling of peripheral blood is often employed for the identification of susceptibility genes or biomarkers of human phenotypes and diseases7,17,18. Blood gene expression profiles can be significantly affected by blood collection and RNA isolation methods10,19,20,21. This is mainly due to the differences in the composition of RNA-stabilizing solutions or differences in the chemistries employed by the different RNA isolation methods. As the manual protocol employs spin columns while the automated protocol uses a magnetic beads approach, we questioned whether the use of the two different methods in this study could have impacted the RNA QC and gene expression profiles. Although we found significant differences in RNA quality and yield, overall the gene expression profiles were maintained, and the inter-individual differences were reproducible across the different extraction methods. The transcriptomic profiles were in fact driven mainly by the subject assignment rather than by analytical variables, suggesting that the Lexogen QuantSeq 3′ FWD mRNA-Seq is a robust method for gene expression profiling. The Lexogen QuantSeq 3′ FWD mRNA-Seq has a streamlined protocol, does not require RNA fragmentation before reverse transcription and only detects the 3′ end of the mRNA, thus it has been employed for low input and highly degraded RNA22,23,24. The present study supports the Lexogen QuantSeq 3′ FWD mRNA-Seq application for RNA isolated from small volumes of blood.
Especially when working on small volumes of samples, pipetting accuracy and reproducibility are of critical importance; automated RNA isolation systems reduce manual errors and should ensure a higher data reproducibility13,25. Automated solutions are currently applied in many fields of life sciences; especially in genomics, laboratory specialists are streamlining their protocols by using automated workstations26,27,28. Automated solutions help cutting costs associated to manual labor and also help wet-lab specialists who would not have to spend long time processing samples15. In our study we questioned whether consistent expression profiles could be obtained from the automated isolation of volumes of blood < 50 μl. We found that volumes of blood samples as low as 16 μl provide reliable transcriptomic profiles; interestingly, these samples displayed the lowest variability, suggesting that our in-house approach could be applied in studies where blood is limited.
Other groups have employed TURBO DNA Free treatment for transcriptomic profiles29,30. However, to the best of our knowledge this is the first assessment on the effect of TURBO DNA Free treatment on RNA isolated from small volumes of blood by using a manual and an automated workflow. The TURBO DNA Free treatment impacted more negatively the samples processed manually. The DNase inactivation reagent is in fact known to sequester divalent cations, change the buffer condition and interfere with enzymatic reactions. In our study, when we compared the automated and manual workflows both including the TURBO DNA Free treatment, we found the treatment to have a stronger negative impact on the manual samples, likely because the treatment is performed at the end of the workflow, differently to the automated protocol.
We expect this study to increase the adoption of automation systems for RNA isolation from small volumes of blood especially in core facility settings where sample throughput and turn-around-time are of critical importance.
Conclusion
Collectively, these results indicate that transcriptomic profiles obtained using the Lexogen QuantSeq 3′ FWD mRNA-Seq protocol are highly reproducible across different extraction methods employed for small volumes of blood, despite differences in RNA quantity and quality. The TURBO DNase treatment should be avoided when isolating RNA from small volumes of blood. The data produced from the automated method displayed less variability as compared to the manual method.
Data availability
The datasets generated and analyzed during the current study are available in the Gene Expression Omnibus (GEO) repository, [https://www.ncbi.nlm.nih.gov/geo/query/acc.cgi?acc=GSE210812].
References
Aarem, J. et al. Comparison of blood RNA isolation methods from samples stabilized in Tempus tubes and stored at a large human biobank. BMC Res. Notes 9, 430. https://doi.org/10.1186/s13104-016-2224-y (2016).
Adams, M. D. et al. Complementary DNA sequencing: expressed sequence tags and human genome project. Science 252, 1651–1656. https://doi.org/10.1126/science.2047873 (1991).
Asare, A. L. et al. Differential gene expression profiles are dependent upon method of peripheral blood collection and RNA isolation. BMC Genom. 9, 474. https://doi.org/10.1186/1471-2164-9-474 (2008).
Berglund, E. et al. Automation of Spatial Transcriptomics library preparation to enable rapid and robust insights into spatial organization of tissues. BMC Genom. 21, 298. https://doi.org/10.1186/s12864-020-6631-z (2020).
Bougarn, S., Boughorbel, S., Chaussabel, D. & Marr, N. A curated transcriptome dataset collection to investigate inborn errors of immunity. F1000Res 8, 188. https://doi.org/10.12688/f1000research.18048.2 (2019).
Byron, S. A., Van Keuren-Jensen, K. R., Engelthaler, D. M., Carpten, J. D. & Craig, D. W. Translating RNA sequencing into clinical diagnostics: opportunities and challenges. Nat. Rev. Genet. 17, 257–271. https://doi.org/10.1038/nrg.2016.10 (2016).
Casamassimi, A., Federico, A., Rienzo, M., Esposito, S. & Ciccodicola, A. Transcriptome profiling in human diseases: New advances and perspectives. Int. J. Mol. Sci. 18, 1652. https://doi.org/10.3390/ijms18081652 (2017).
Debey-Pascher, S., Eggle, D. & Schultze, J. L. RNA stabilization of peripheral blood and profiling by bead chip analysis. Methods Mol. Biol. 496, 175–210. https://doi.org/10.1007/978-1-59745-553-4_13 (2009).
Hantzsch, M. et al. Comparison of whole blood RNA preservation tubes and novel generation RNA extraction kits for analysis of mRNA and MiRNA profiles. PLoS One 9, e113298. https://doi.org/10.1371/journal.pone.0113298 (2014).
Jang, J. S. et al. Application of the 3′ mRNA-Seq using unique molecular identifiers in highly degraded RNA derived from formalin-fixed, paraffin-embedded tissue. BMC Genom. 22, 759. https://doi.org/10.1186/s12864-021-08068-1 (2021).
Jarvis, S., Birsa, N., Secrier, M., Fratta, P. & Plagnol, V. A comparison of low read depth QuantSeq 3′ sequencing to total RNA-Seq in FUS mutant mice. Front. Genet. 11, 562445. https://doi.org/10.3389/fgene.2020.562445 (2020).
Jemt, A. et al. An automated approach to prepare tissue-derived spatially barcoded RNA-sequencing libraries. Sci. Rep. 6, 37137. https://doi.org/10.1038/srep37137 (2016).
Lockhart, D. J. & Winzeler, E. A. Genomics, gene expression and DNA arrays. Nature 405, 827–836. https://doi.org/10.1038/35015701 (2000).
Ma, F. et al. A comparison between whole transcript and 3′ RNA sequencing methods using Kapa and Lexogen library preparation methods. BMC Genom. 20, 9. https://doi.org/10.1186/s12864-018-5393-3 (2019).
Manjunath, H. S., Kalikiri, M. K. R., Kabeer, B. S. A. & Tomei, S. When mosquito HV bites Biomark HD: An automated workflow for high-throughput qPCR. SLAS Technol. 27, 219–223. https://doi.org/10.1016/j.slast.2021.12.007 (2022).
Mathew, R. et al. Influence of storage conditions of small volumes of blood on immune transcriptomic profiles. BMC Res. Notes 13, 150. https://doi.org/10.1186/s13104-020-04980-z (2020).
Matsushima, W. et al. Sequencing cell-type-specific transcriptomes with SLAM-ITseq. Nat. Protoc. 14, 2261–2278. https://doi.org/10.1038/s41596-019-0179-x (2019).
Menke, A., Rex-Haffner, M., Klengel, T., Binder, E. B. & Mehta, D. Peripheral blood gene expression: It all boils down to the RNA collection tubes. BMC Res. Notes 5, 1. https://doi.org/10.1186/1756-0500-5-1 (2012).
Nikula, T., Mykkanen, J., Simell, O. & Lahesmaa, R. Genome-wide comparison of two RNA-stabilizing reagents for transcriptional profiling of peripheral blood. Transl. Res. 161, 181–188. https://doi.org/10.1016/j.trsl.2012.10.003 (2013).
Richards, J., Unger, E. R. & Rajeevan, M. S. Simultaneous extraction of mRNA and microRNA from whole blood stabilized in tempus tubes. BMC Res. Notes 12, 39. https://doi.org/10.1186/s13104-019-4087-5 (2019).
Rinchai, D., Anguiano, E., Nguyen, P. & Chaussabel, D. Finger stick blood collection for gene expression profiling and storage of tempus blood RNA tubes. F1000Res 5, 1385. https://doi.org/10.12688/f1000research.8841.2 (2016).
Robison, E. H. et al. Whole genome transcript profiling from fingerstick blood samples: A comparison and feasibility study. BMC Genom. 10, 617. https://doi.org/10.1186/1471-2164-10-617 (2009).
Rohland, N. & Reich, D. Cost-effective, high-throughput DNA sequencing libraries for multiplexed target capture. Genome Res. 22, 939–946. https://doi.org/10.1101/gr.128124.111 (2012).
Shin, J. et al. CRISPRpas: Programmable regulation of alternative polyadenylation by dCas9. Nucleic Acids Res. 50, e25. https://doi.org/10.1093/nar/gkab519 (2022).
Skogholt, A. H. et al. Gene expression differences between PAXgene and Tempus blood RNA tubes are highly reproducible between independent samples and biobanks. BMC Res. Notes 10, 136. https://doi.org/10.1186/s13104-017-2455-6 (2017).
Storch, M., Haines, M. C. & Baldwin, G. S. DNA-BOT: A low-cost, automated DNA assembly platform for synthetic biology. Synth. Biol. (Oxf.) 5, ysaa010. https://doi.org/10.1093/synbio/ysaa010 (2020).
Taylor, S. A., Tsang, A. O., Fu, K. H., Kalousek, D. K. & Horsman, D. E. Comparative study of automated versus manual extraction of DNA from clinical specimens. Am. J. Clin. Pathol. 93, 749–753. https://doi.org/10.1093/ajcp/93.6.749 (1990).
Tegally, H., San, J. E., Giandhari, J. & de Oliveira, T. Unlocking the efficiency of genomics laboratories with robotic liquid-handling. BMC Genom. 21, 729. https://doi.org/10.1186/s12864-020-07137-1 (2020).
Tenedini, E. et al. Automated capture-based NGS workflow: One thousand patients experience in a clinical routine framework. Diagnosis (Berl) 9, 115–122. https://doi.org/10.1515/dx-2021-0051 (2021).
Tsang, J. S. et al. Global analyses of human immune variation reveal baseline predictors of postvaccination responses. Cell 157, 499–513. https://doi.org/10.1016/j.cell.2014.03.031 (2014).
Funding
Open Access funding provided by the Qatar National Library.
Author information
Authors and Affiliations
Contributions
M.K.R.K. developed the in-house automated RNA isolation method and processed the automated extraction. H.S.M. performed the manual RNA extraction and RNA QC. F.R.V. processed the sequencing data and performed all the bioinformatic data analyses. L.S.M. and L.L. performed RNA QC, prepared the libraries for RNAseq and performed libraries QC. L.W., G.W., K.W. quantified the libraries and performed the Illumina sequencing. O.S. and S.L. provided insightful technical feedback. S.T. designed the study and wrote the manuscript. All authors discussed the results. All authors reviewed and approved the submitted version of the manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Kalikiri, M.K.R., Manjunath, H.S., Vempalli, F.R. et al. Technical assessment of different extraction methods and transcriptome profiling of RNA isolated from small volumes of blood. Sci Rep 13, 3598 (2023). https://doi.org/10.1038/s41598-023-30629-5
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-023-30629-5
- Springer Nature Limited