Abstract
Cell-free biosensors are promising tools for medical diagnostics, yet their performance can be affected by matrix effects arising from the sample itself or from external components. Here we systematically evaluate the performance and robustness of cell-free systems in serum, plasma, urine, and saliva using two reporter systems, sfGFP and luciferase. In all cases, clinical samples have a strong inhibitory effect. Of the different inhibitors, only RNase inhibitor mitigated matrix effects. However, we found that the recovery potential of RNase inhibitor was partially muted by interference from glycerol contained in the commercial buffer. We solved this issue by designing a strain producing an RNase inhibitor protein requiring no additional step in extract preparation. Furthermore, our new extract yielded higher reporter levels than previous conditions and tempered interpatient variability associated with matrix effects. This systematic evaluation and improvements of cell-free system robustness unified across many types of clinical samples is a significant step towards developing cell-free diagnostics for a wide range of conditions.
Similar content being viewed by others
Introduction
Biosensors are detection tools that integrate a biological recognition element from a sensor module and transduce the signal into a quick, measurable response1. Rapid point-of-care testing applications are an alternative to complex technical procedures in clinical settings and reduce the need for time-consuming and equipment-dependent sample processing. Hence, portable biosensors allow close monitoring of chronic disease, as exemplified by portable glucose monitoring devices that have revolutionized diabetes care2. These tools are adapted to a real-time assessment of such clinical populations and more precisely determine clinical outcomes. In this way, less biased data are simply and repeatedly sampled outside the clinical setting while taking into account the patient’s own environment and variability3. Moreover, biosensors are particularly promising tools for field diagnostics in low-resource settings4, especially in the context of transmissible infectious and endemic diseases such as HIV5, malaria6, or Zika7. The poor testing response of many countries to COVID-19 has highlighted the importance of rapid, low-cost, and easily distributable diagnostic devices worldwide8.
Among the vast array of available technologies, cell-free expression systems have recently emerged as promising candidates for versatile biosensor engineering9,10 as they support the operation of sophisticated genetic circuits while requiring small reaction volumes11. Compared to whole-cell biosensors, cell-free systems can detect molecules like nucleic acids that do not cross cellular membranes, as well as ones typically toxic to living cells. In addition to being abiotic and non-replicating, with little need for biocontainment measures, cell-free expression systems endure no evolutionary pressure that can alter whole-cell biosensors. Reactions can occur at ambient or body temperature, by taping the sensor to the skin for example12, eliminating equipment like incubators at the point of detection. Performances are easily tunable by varying extract and plasmid composition, and the protein expression yield may be optimized through a large variety of methods13. Cell-free biosensors can be lyophilized and kept stable at room temperature for up to one year14 and may provide rapid responses in as little as under 1 h15. The combination of engineered cell-free transcription and translation (TX-TL) systems with electrochemical platforms further enables multiplexed biomarker detection16.
Overall, with short reaction times, long-term storage, and the compatibility with nano-electrode interfaces16, cell-free systems are good candidates toward point-of-care testing of pathological biomarkers in clinical settings and remote locations. The emergence of decentralized, portable diagnostics may improve the acquisition of epidemiological data worldwide, which is proving critical in planning global healthcare measures to mitigate the effects of non-communicable diseases and recent outbreaks, such as Zika or the COVID-19 pandemic17. Yet, some issues are currently limiting the translation of cell-free diagnostic platforms to clinical use, such as cross detection of non-identified markers, or most importantly, the interference from biological samples. Variability in the components of complex samples can affect the readouts of even sophisticated analytical instrumentation, a phenomenon known as matrix effects that can yield inaccurate results18. These effects were reported in several types of biosensors produced in E. coli extracts that have been tested using human samples (Table 1).
Although the final aim of cell-free biosensors is their field deployment and the point-of-care testing of pathogenic biomarkers, only sparse studies have systematically assessed the performance of cell-free biosensors in multiple different types of human biological samples19,22,23. Here, we monitored the performance of E. coli TX-TL cell-free extract across four types of clinical samples taken from patients in hospital settings through minimally invasive methods. Samples were not processed before testing except in their basic preparation (i.e. blood centrifugation for serum and plasma after collection in appropriate vacuum tubes). We tested matrix effects of the samples on both constitutively-produced superfolder green fluorescent protein (sfGFP) and firefly luciferase15. In addition, we systematically examined the improvement of the E. coli TX-TL cell-free system by adding RNase and protease inhibitors. Importantly, we found that the glycerol present in commercial RNase inhibitors reduces cell-free protein production. As such, we developed an E. coli strain that can produce its own RNase inhibitor in situ during extract production without any additional procedure steps, simultaneously eliminating the cost of commercial inhibitors and increasing protein production in the presence of clinical samples over that obtained when they are used. Finally, we examined the interpatient variability effects through testing ten serum, plasma, and urine patient samples. Our new extract reduced interpatient variability, particularly for plasma samples. By probing the effects of both pooled and individual patient samples across an array of different types of clinical samples and providing an easier way to mitigate their matrix effects, our results represent a significant step forward in developing cell-free diagnostics for a range of biomarkers and pathological conditions.
Results
Clinical sample matrix strongly inhibits reporter production in cell-free biosensors
We first measured the matrix effects of various clinical samples (serum, plasma, urine and saliva) on cell-free activity. To do so, we monitored the production of two constitutively expressed reporters, superfolder GFP (sfGFP) and firefly luciferase (Luc) in the presence or absence of clinical samples. We chose sfGFP and luciferase because they are both common reporters widely used for signal quantification. Plasmids constitutively expressing sfGFP or luciferase were mixed with E. coli TX-TL extract prepared using a French press as previously described15, and an optimized buffer containing the necessary building blocks, salts, and energy source for transcription and translation. Finally, as these core reaction components take up 80–90% of the available reaction volume, non-processed clinical samples were added to the reaction mix as 10% of the final reaction volume (Fig. 1A).
We quantified the matrix effects of different clinical samples on constitutive reporter expression in the absence or presence of RNase inhibitor and two protease inhibitors (bacterial and mammalian) relative to a positive control with neither clinical sample nor inhibitor (Fig. 1B,C). We found that all clinical samples had an inhibitory effect on reporter production, albeit to a different extent. Without any inhibitors, serum and plasma almost completely impeded reporter production (> 98% inhibition with respect to no sample addition). Urine inhibited more than 90% of reporter production for both sfGFP and Luc with respect to no sample addition, whereas saliva produced the least interference for both reporters (70% inhibition on luciferase and 40% on sfGFP, with respect to control).
Commercial RNase inhibitor partially restores cell-free activity while protease inhibitors display poor mitigation of matrix effects
We tested two categories of additives inhibiting enzymatic activities that could affect the reactions: RNases and proteases. RNase inhibitor was previously shown to improve the efficiency of cell-free reactions19 in some types of clinical samples or was systematically added to cell-free reactions with biological fluids15,18. Also, endogenous proteases from E. coli extracts have been suggested to affect the yield of protein synthesis24,25. We choose to test both bacterial and mammalian protease inhibitors to account for proteases found in both the E. coli extract and in the human clinical samples. While the use of RNase inhibitors has been previously tested19, no previous study has evaluated neither protease inhibitors nor all four of the clinical samples described here.
The addition of RNase inhibitor improved sfGFP production by about 70% in urine, 20% in serum, and 40% in plasma, while bacterial and mammalian protease inhibition failed to improve cell-free reaction performance in any of the clinical samples (Fig. 1B). Results were comparable in all conditions when using the firefly luciferase reporter. The addition of RNase inhibitor restored luciferase signals in saliva, plasma, serum, and to a lesser extent in urine, reaching 50% of the luciferase production from the absence of a clinical sample (Fig. 1C). As with sfGFP, bacterial and mammalian protease inhibitors did not produce significant improvement on cell-free protein synthesis for the Luc reporter.
Glycerol present in the commercial buffer of enzymatic inhibitors is responsible for signal degradation in cell-free reactions
While RNase inhibitors generally led to increased protein production in the presence of clinical samples, in all cases full signal (i.e. when no clinical sample was present) was never recovered. Additionally, we tested the effect of inhibitors in cell-free reactions without any clinical sample (Supplementary Fig. 1) and observed that all of them degraded reporter production, with RNase inhibitor being the most detrimental (~ 50% reduction of signal with respect to no inhibitor). We wondered if the buffer composition of the commercial RNase inhibitor could be responsible for this phenomenon. First, we compared cell-free reaction efficiency, with and without RNase inhibitor, vs. buffer with identical components as listed by the manufacturer (50 mM KCl, 20 mM HEPES, 8 mM DTT, 50% glycerol) (Fig. 2A). Indeed, there was a marked decrease in protein production from adding RNase inhibitor that was identical to that of adding the buffer alone. This result was consistent over a range of plasmid concentrations (Supplementary Fig. 2). To disentangle which part of the buffer was responsible, we separately added each component of the commercial buffer to the cell-free reaction, individually and in all possible combinations (Fig. 2B). We found that glycerol alone (at 1% final reaction concentration) accounted in all cases for the sfGFP production decrease independently of the presence of any other component of the buffer. These data demonstrate that the decrease of cell-free reaction performance observed when adding RNase inhibitor is exclusively due to the glycerol contained in the buffer solution.
In situ RNase inhibitor production allows equivalent protection to that of commercial inhibitor while allowing higher reporter production
We then hypothesized that we could avoid glycerol inhibition by expressing RNase inhibitor in E. coli while growing the cell-free extract. This would prevent the need for glycerol and have the added benefit of reducing the overall reaction cost. After cloning a codon-optimized version of the murine RNase inhibitor (mRI) gene into a plasmid under a T7 promoter, we transformed it into competent E. coli for extract production. Because adding IPTG during the growth process is a common cell-free practice for producing T7 RNA polymerase in situ, having the mRI gene under a T7 promoter would allow both high mRI production and potentially require no additional steps in the process (Fig. 2C).
To examine whether our mRI-expressing strain could indeed protect against RNases as efficiently as the commercial product, we evaluated the reporter signal vs. increasing concentrations of RNaseA for the standard extract with and without commercial mRI against our mRI-expressing extract (Fig. 2D). While protein production with no inhibitor sharply drops to almost no production with less than 0.1 µg/mL RNaseA, both commercial and doped mRI extracts show no decrease in signal up to 0.3 µg/mL of RNaseA and can still produce a measurable signal when confronted with up to 3 µg/mL. Importantly, when examining the absolute signal of each condition, the mRI-expressing extract shows more than ten times higher levels of protein production than the glycerol-inhibited commercial mRI reactions (Fig. 2E, Supplementary Fig. 3). Thus, our mRI-expressing extract provided equivalent levels of relative RNase protection to that of the commercial inhibitor while allowing for much higher absolute levels of protein production.
mRI-expressing cell extracts outperform the use of commercial reagents with clinical samples
We sought to compare the performance in clinical samples of our mRI-expressig extract relative to extract supplemented with commercial RNase inhibitor. We tested serum, plasma, urine, and saliva using standard extract, standard extract with commercial mRI, and mRI-expressing extract for constitutive sfGFP expression (Fig. 3A,B). While matrix effects still reduced overall protein expression, the mRI-expressing extract showed marked improvement in fluorescent signal over standard extract supplemented with commercial inhibitor (Fig. 3C). This demonstrates that the effects observed in reducing RNase activity observed with extract-expressed RNase translate to an improvement with clinical samples as well, while avoiding the costs and glycerol effects of commercial inhibitors.
Most studies examining the development and optimization of cell-free based biosensors employ pooled clinical samples or artificial equivalents of clinical samples. We thought that our system, which did not directly measure the presence of any biomarker, represented an optimal benchmark opportunity to study matrix variability from patient to patient. Furthermore, we wished to test if in situ production of mRI further mitigated interpatient matrix effects. We examined, over three consecutive days, the ten different patient samples of serum, plasma, and urine, ensuring independence between measurements (Fig. 3D) on the presence of commercial inhibitor or with our mRI-expressing extract. The dispersion of the data was significantly lower when using the mRI-expressing extract for plasma samples, although all groups demonstrated variance between patients. These results highlight that despite improved protein production with RNase inhibitors, significant challenges likely remain to develop cell-free diagnostics with sufficient robustness to function with the variability between patient samples and sampling conditions in a point-of-care setting.
Discussion
Our workflow provides unified data and systematic studies of the performance of a TX-TL cell-free system in a wide variety of clinical human samples. We studied and compared the matrix effects in complex media and assessed simple and reproducible optimization strategies. We further examined an expanded range of inhibitors likely to have a beneficial effect on performance, including mammalian and protease inhibitors. The knowledge of the interference with human biological samples and of possible optimization strategies is important to translate the use of cell-free based biosensors to real clinical populations with a broad range of pathological conditions. This step is crucial to achieve their potential as next-generation platforms for rapid, low-cost, field diagnostics. Our procedure is straightforward, reproducible, and may be applied in real clinical settings to validate the use of TX-TL cell-free biosensors on a large scale.
One of the strengths of our workflow is the absence of sample preprocessing that would require heavy technical methods, such as analyte extraction or protein phase separation20. The only sample processing was the standard centrifugation procedure applied to obtain serum and plasma from whole blood tubes. Our data support the expansion of cell-free biosensors to a variety of fresh human samples in remote settings without the need for complex technical sample processing. In assays where blood plasma or serum are required, these biosensors could be coupled with low-tech centrifuges, like the paperfuge or egg-beater centrifuge, for sample preparation26,27.
We compared the signal output from two well-known reporter modules, sfGFP and luciferase, in a variety of clinical samples. The reporter's signal was strongly thwarted by the addition of clinical samples in all cases, although saliva showed the least inhibition effects. The significant drop in performance and partial restoration by addition of RNase inhibitor in serum and plasma may be explained by the large amounts of pancreatic type ribonucleases secreted by endothelial cells from arteries, veins, and capillaries28. Similarly, human urine has long been known to contain multiple types of RNase activity29. Interestingly, while human saliva can exhibit ribonuclease activity, particularly under certain pathological conditions30, our results suggest that it does not itself always significantly contribute to the sample matrix effects. One potential downside to sfGFP as a reporter for point-of-care diagnostics is the need to produce low-cost devices that can excite the fluorescent protein and filter out the emission signal; however, other groups have worked to design 3D-printed fluorescent readers that could work well for this purpose31. Compared with sfGFP use, the drawback to using luciferase in clinical settings is the need to add luciferase substrate (luciferin) to trigger light emission. However, luciferase-associated sensors have the advantage of providing a detectable signal for simple optical devices that need no external light source for stimulation. Some studies have reported simple signal detection with smartphone cameras which may be easily handled at the patient’s bedside32,33. Additionally, other reporters that induce a color change, such as LacZ14 or C23DO12, could provide a simple, visual output result.
Some of the specific effects of the RNase inhibitor were likely muted, impairing full signal recovery. We found that glycerol contained in the RNase inhibitor commercial buffer was responsible for the reduced efficiency of cell-free reactions. While evidence of glycerol inhibition of cell-free reactions has been previously reported34, the lack of current glycerol-free RNase inhibitors precludes another viable commercial option. We decided to sidestep the glycerol effects by designing an E. coli plasmid that could produce mRI in situ during the extract preparation process. We found that by producing mRI under the control of a T7 promoter during the cell growth phase, we created a cell extract that could protect against RNaseA as well as a commercial RNase inhibitor without the overall signal reducing effects of buffer glycerol. Additionally, due to the absence of glycerol, this extract exhibited much higher signal in the presence of clinical samples. While recent publications have similarly produced mRI to help protect against clinical matrix effects, they required multiple reactions or the combination of multiple extracts grown at different temperatures with additional folding chaperones22,23. In contrast, our strain does not require any additional steps, aside from adding IPTG during cell growth, which is already commonly done to induce T7 polymerase production in cell-free extracts.
Finally, we examined the interpatient variability of three different clinical samples, serum, plasma, and urine, using a commercial inhibitor and our doped mRI extract. Using ten individual samples of each, we found that the matrix effects produced less variability between patient plasma samples when using the mRI-expressing extract. This kind of validation, using a large number of individual patients, is essential for the development of new biosensors, as we show that matrix effects can be so significant as to completely abolish protein production in one patient's urine sample. As concentrations of different ions and metabolites can vary widely in urine depending on patient hydration35, it is perhaps not surprising to see large variability; however, these findings highlight that significant robustness remains to be engineered into cell-free diagnostics before they can be reliably used in a point-of-care setting. Interestingly, blood plasma showed the lowest interpatient variability. While blood plasma and serum can frequently be used interchangeably, the coagulation process in acquiring serum can lead to changes in certain platelet components, such as aspartate aminotransferase, lactate dehydrogenase, fibrin/fibrinogen, and serotonin36. Further studies could investigate which components specifically influence cell-free expression, but our work indicates that plasma may be a good clinical sample candidate for future applications requiring a high degree of reproducibility, as in chronic conditions or long-term follow-up studies or diagnostics.
Overall, these results represent a comprehensive overview of some of the promise and potential challenges of using cell-free systems for clinical diagnostics with unprocessed samples. In addition to providing a dataset that compares four types of commonly used clinical samples across a unified set of experiments, it represents, to the best of our knowledge, the first time that blood plasma has been used in cell-free reactions. Additionally, saliva is of particular interest since it involves a pain-free, non-invasive collection process and can be potentially used to monitor the advancement of neurodegenerative and neuropsychiatric disorders like autism, Alzheimer’s, Parkinson’s, and Huntington’s disease, in addition to the oral microbiome, which is involved in dental and periodontal health37,38. Opening cell-free biosensors to a broader range of clinical samples and ensuring their reliability through systematic optimization will help provide portable, low-cost diagnostics tools to address global health challenges.
Materials and methods
Molecular biology
The reporter plasmid for sfGFP (pBEAST2-sfGFP) was previously characterized15 and is available on Addgene (#126575). The plasmid for luciferase (pBEST-Luc) was obtained from Promega. DNA for cell-free reactions was prepared from overnight bacterial cultures using Maxiprep kits (Macherey–Nagel).
To create the plasmid to induce murine RNase inhibitor expression in E. coli extract, the amino acid sequence was obtained from Uniprot (#Q91VI7), codon-optimized for E. coli, and synthesized by Twist Bioscience. It was then cloned by Gibson assembly into the pBEAST backbone under the control of a T7 promoter and transformed into either BL21 Star or BL21 Star (DE3)::RF1-CBD3 E. coli for extract production. The final plasmid, pPLV_C1, will be available from Addgene (#186415).
Cell-extract preparation
Cell-free E. coli extracts were produced using a modified version of existing protocols as previously detailed15. Briefly, an overnight culture of BL21 Star or BL21 Star (DE3)::RF1-CBD3 E. coli was used to inoculate 660 mL of 2xYT-P media in each of six 2 L flasks at a dilution of 1:100. The cultures were grown at 37 °C with 220 r.p.m. shaking for ~ 3.5 h until OD 600 = 2.0. For the mRI-expressing extract, cultures were induced with 1 mM IPTG at OD 600 = 0.4–0.6. Cultures were spun down at 5000×g at 4 °C for 12 min. Cell pellets were washed twice with 200 mL S30A buffer (14 mM Mg-glutamate, 60 mM K-glutamate, 50 mM Tris, pH 7.7), centrifuging afterward at 5000×g at 4 °C for 12 min. Cell pellets were then resuspended in 40 mL S30A buffer and transferred to preweighed 50 mL Falcon conical tubes, where they were centrifuged twice at 2000×g at 4 °C for 8 and 2 min, removing the supernatant after each. Finally, the tubes were reweighed and flash-frozen in liquid nitrogen before storing at − 80 °C.
Cell pellets were thawed on ice and resuspended in 1 mL S30A buffer per gram cell pellet. The suspensions were lysed via a single pass through a French press homogenizer (Avestin; Emulsiflex-C3) at 15,000–20,000 psi and then centrifuged at 12,000 × g at 4 °C for 30 min to separate out cellular cytoplasm. After centrifugation, the supernatant was collected and incubated at 37 °C with 220 rpm shaking for 60 min to digest the remaining mRNA with endogenous nucleases. Subsequently, the extract was re-centrifuged at 12,000×g at 4 °C for 30 min and the supernatant was transferred to 12–14 kDa molecular weight cut-off (MWCO) dialysis tubing (Spectrum Labs; Spectra/Por4) and dialyzed against 2 L of S30B buffer (14 mM Mg-glutamate, 60 mM K-glutamate, ~ 5 mM Tris, pH 8.2) overnight at 4 °C. The following day, the extract was re-centrifuged at 12,000 × g at 4 °C for 30 min. The supernatant was aliquoted and flash-frozen in liquid nitrogen before storage at − 80 °C.
Cell-free reaction optimization
Cell-free reactions were prepared by mixing 33.3% cell extract, 41.7% buffer, and 25% plasmid DNA, clinical samples, inhibitors, and water. Buffer composition was such that final reaction concentrations were as follows: 1.5 mM each amino acid, 50 mM HEPES, 1.5 mM ATP and GTP, 0.9 mM CTP and UTP, 0.2 mg/mL tRNA, 0.26 mM CoA, 0.33 mM NAD, 0.75 mM cAMP, 0.068 mM folinic acid, 1 mM spermidine, 30 mM 3-PGA, and 2% PEG-8000. In addition, the Mg-glutamate (0–20 mM), K-glutamate (20–300 mM), and DTT (0–3 mM) levels were serially calibrated for each batch of cell extract for maximum signal. Reactions using constitutively expressing sfGFP or luciferase plasmids were performed at a final DNA concentration of 10 nM or 100 nM. For testing with an RNaseA gradient, RNaseA (Qiagen) was diluted in water and added at 10% reaction volume to their final concentrations.
The sfGFP-output reactions were prepared in PCR tubes on ice and 20 μL was transferred to a black, clear-bottom 384-well plate (ThermoScientific), sealed, and the reaction was carried out at 37 °C in a plate reader (Biotek; Cytation3) to measure fluorescence over time. Mean equivalent fluorescence (MEF) of soluble fluorescein isothiocyanate (FITC) was calculated based on measurements of a standard gradient under identical excitation/emission and gain settings as previously published by ourselves and others31,39. Luciferase-output reactions were incubated at 37 °C for 8 h. Samples were then transferred to white 96-well plates and 50 μL of Bright-Glo Luciferase Assay Reagent (Promega) was added and mixed by manual orbital agitation. The plates were sealed and luciferase levels were measured in a plate reader 5 min after the addition of the reagent. The subsequent data were processed and graphs were created using Python scripts.
Cell-free reactions with human urine, saliva, plasma, and serum
Cell extract and buffer conditions were maintained from those used in optimization reactions. Saliva, urine, serum, and plasma were pooled from three individual patient samples to reduce patient-specific inhibition effects. 10% reaction volume of each sample was included in 20 μL reactions containing extract, buffer, DNA, and inhibitors when applicable. In addition, where applicable reactions were supplemented with 0.32 units of murine RNase Inhibitor (New England Biolabs, #M0314), 1X equivalent of mammalian protease inhibitor (100X stock solution Euromedex, #B14011), or 1X equivalent of bacterial protease inhibitor (10X stock solution Sigma-Aldrich, #P8465).
Statistical analysis
Standard deviations for figures were calculated and plotted using Numpy-based Python scripts. F-tests of variance were performed using the statistical package scipy.
Use of human participants
All experiments were performed in accordance with relevant guidelines and regulations. Human urine samples were obtained from the Endocrinology Department at the University of Montpellier in accordance with ethics committee approval (#190102). Human blood samples were obtained from the EFS (Etablissement Français du Sang). Saliva was issued from the samples collected in the SADS-CS study conducted in the Department of Emergency Psychiatry and Acute Care, Hôpital Lapeyronie, CHU Montpellier (Ethics committee approval: CPP Sud-Méditerranée-V, #15.073). Informed consent was obtained from all participants and no patients under the age of 16 were part of this study.
Data availability
The datasets used and/or analyzed during the current study available from the corresponding author on reasonable request.
References
Kim, J., Campbell, A. S., de Ávila, B.E.-F. & Wang, J. Wearable biosensors for healthcare monitoring. Nat. Biotechnol. 37, 389–406 (2019).
Courbet, A., Endy, D., Renard, E., Molina, F. & Bonnet, J. Detection of pathological biomarkers in human clinical samples via amplifying genetic switches and logic gates. Sci. Transl. Med. 7, 289ra83 (2015).
Shiffman, S., Stone, A. A. & Hufford, M. R. Ecological momentary assessment. Annu. Rev. Clin. Psychol. 4, 1–32 (2008).
Sharma, S., Zapatero-Rodríguez, J., Estrela, P. & O’Kennedy, R. Point-of-care diagnostics in low resource settings: Present status and future role of microfluidics. Biosensors 5, 577–601 (2015).
Saylan, Y., Erdem, Ö., Ünal, S. & Denizli, A. An alternative medical diagnosis method: biosensors for virus detection. Biosensors 9, 65 (2019).
Ragavan, K. V., Kumar, S., Swaraj, S. & Neethirajan, S. Advances in biosensors and optical assays for diagnosis and detection of malaria. Biosens. Bioelectron. 105, 188–210 (2018).
Pardee, K. et al. Rapid, low-cost detection of Zika virus using programmable biomolecular components. Cell 165, 1255–1266 (2016).
Udugama, B. et al. Diagnosing COVID-19: The disease and tools for detection. ACS Nano 14, 3822–3835 (2020).
Voyvodic, P. L. & Bonnet, J. Cell-free biosensors for biomedical applications. Curr. Opin. Biomed. Eng. 13, 9–15 (2020).
Silverman, A. D., Karim, A. S. & Jewett, M. C. Cell-free gene expression: An expanded repertoire of applications. Nat. Rev. Genet. 21, 151–170 (2020).
Garamella, J., Marshall, R., Rustad, M. & Noireaux, V. The All E. coli TX-TL toolbox 2.0: A platform for cell-free synthetic biology. ACS Synth. Biol. 5, 344–355 (2016).
Thavarajah, W. et al. Point-of-use detection of environmental fluoride via a cell-free riboswitch-based biosensor. ACS Synth. Biol. 9, 10–18 (2019).
Koch, M., Pandi, A., Borkowski, O., Cardoso Batista, A. & Faulon, J.-L. Custom-made transcriptional biosensors for metabolic engineering. Curr. Opin. Biotechnol. 59, 78–84 (2019).
Pardee, K. et al. Paper-based synthetic gene networks. Cell 159, 940–954 (2014).
Voyvodic, P. L. et al. Plug-and-play metabolic transducers expand the chemical detection space of cell-free biosensors. Nat. Commun. 10, 1697 (2019).
Sadat Mousavi, P. et al. A multiplexed, electrochemical interface for gene-circuit-based sensors. Nat. Chem. 12, 48–55 (2020).
Mujawar, M. A. et al. Aspects of nano-enabling biosensing systems for intelligent healthcare; towards COVID-19 management. Mater. Today Chem. 17, 100306 (2020).
McNerney, M. P. et al. Point-of-care biomarker quantification enabled by sample-specific calibration. Sci. Adv. 5, eaax4473 (2019).
Salehi, A. S. M. et al. Biosensing estrogenic endocrine disruptors in human blood and urine: A RAPID cell-free protein synthesis approach. Toxicol. Appl. Pharmacol. 345, 19–25 (2018).
Wen, K. Y. et al. A cell-free biosensor for detecting quorum sensing molecules in P aeruginosa-infected respiratory samples. ACS Synth. Biol. 6, 2293–2301 (2017).
Salehi, A. S. M. et al. Cell-free protein synthesis approach to biosensing hTRβ-specific endocrine disruptors. Anal. Chem. 89, 3395–3401 (2017).
Soltani, M. & Bundy, B. C. Streamlining cell-free protein synthesis biosensors for use in human fluids: In situ RNase inhibitor production during extract preparation. Biochem. Eng. J. 177, 108158 (2022).
Soltani, M., Hunt, J. P. & Bundy, B. C. Rapid RNase inhibitor production to enable low-cost, on-demand cell-free protein synthesis biosensor use in human body fluids. Biotechnol. Bioeng. 118(10), 3973–3983 (2021).
Jiang, X. et al. Reduction of protein degradation by use of protease-deficient mutants in cell-free protein synthesis system of Escherichia coli. J. Biosci. Bioeng. 93, 151–156 (2002).
Ali, M. et al. Improvements in the cell-free production of functional antibodies using cell extract from protease-deficient Escherichia coli mutant. J. Biosci. Bioeng. 99, 181–186 (2005).
Bhamla, M. S. et al. Paperfuge: An ultralow-cost, hand-powered paper-centrifuge inspired by the mechanics of a whirligig toy. APS 2017, V35-012 (2017).
Wong, A. P., Gupta, M., Shevkoplyas, S. S. & Whitesides, G. M. Egg beater as centrifuge: Isolating human blood plasma from whole blood in resource-poor settings. Lab Chip 8, 2032 (2008).
Landré, J. B. P. et al. Human endothelial cells selectively express large amounts of pancreatic-type ribonuclease (RNase 1). J. Cell. Biochem. 86, 540–552 (2002).
Cranston, J. W., Perini, F., Crisp, E. R. & Hixson, C. V. Purification and properties of ribonucleases from human urine. Biochim. Biophys. Acta 616, 239–258 (1980).
Ceder, O., van Dijken, J., Ericson, T. & Kollberg, H. Ribonuclease in different types of saliva from cystic fibrosis patients. Acta Paediatr. Scand. 74, 102–106 (1985).
Jung, J. K. et al. Cell-free biosensors for rapid detection of water contaminants. Nat. Biotechnol. 38, 1451–1459 https://doi.org/10.1038/s41587-020-0571-7 (2020).
Cevenini, L. et al. Exploiting NanoLuc luciferase for smartphone-based bioluminescence cell biosensor for (anti)-inflammatory activity and toxicity. Anal. Bioanal. Chem. 408, 8859–8868 (2016).
Roda, A. et al. Smartphone-based biosensors: A critical review and perspectives. Trends Anal. Chem. 79, 317–325 (2016).
Sun, Z. Z., Yeung, E., Hayes, C. A., Noireaux, V. & Murray, R. M. Linear DNA for rapid prototyping of synthetic biological circuits in an Escherichia coli based TX-TL cell-free system. ACS Synth. Biol. 3, 387–397 (2014).
MacPherson, S., Arbuckle, T. E. & Fisher, M. Adjusting urinary chemical biomarkers for hydration status during pregnancy. J. Expo. Sci. Environ. Epidemiol. 28, 481–493 (2018).
World Health Organization, Use of Anticoagulants in Diagnostic Laboratory Investigations. (2002).
Farah, R. et al. Salivary biomarkers for the diagnosis and monitoring of neurological diseases. Biomed. J. 41, 63–87 (2018).
Yoshizawa, J. M. et al. Salivary biomarkers: Toward future clinical and diagnostic utilities. Clin. Microbiol. Rev. 26, 781–791 (2013).
Batista, A. C. et al. Differentially optimized cell-free buffer enables robust expression from unprotected linear DNA in exonuclease-deficient extracts. ACS Synth. Biol. 11, 732–746 https://doi.org/10.1021/acssynbio.1c00448 (2022).
Acknowledgements
We thank the Bonnet lab members for fruitful discussions. We are grateful to Pau Bernado, Annika Urbanek, and Anna Morato for helpful discussions on cell-free systems and extract creation, Gottfried Otting for BL21 (DE3) Star::RF1-CBD3 strain, and the patients for providing their samples. This work was supported by an ERC starting grant “COMPUCELL” and ANR “SynbioDiag” to J.B. J.B. also acknowledges continuous support from the INSERM Atip-Avenir program and the Bettencourt-Schueller Foundation. The CBS acknowledges support from the French Infrastructure for Integrated Structural Biology (FRISBI) ANR-10-INSB-05-01. All plasmids will be available from Addgene.
Author information
Authors and Affiliations
Contributions
P.L.V., I.C., D.I.C., and J.B. designed experiments. P.L.V, I.C. and K.M. performed experiments. I.C., E.R., and P.C. participated in clinical sample collection. P.L.V., I.C., D.I.C., and J.B. analyzed the data and wrote the paper. All authors approved the manuscript.
Corresponding authors
Ethics declarations
Competing interests
P.L.V. is a shareholder at Twist Bioscience (NYSE: TWST), which was used to synthesize the murine RNase inhibitor.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Voyvodic, P.L., Conejero, I., Mesmoudi, K. et al. Evaluating and mitigating clinical samples matrix effects on TX-TL cell-free performance. Sci Rep 12, 13785 (2022). https://doi.org/10.1038/s41598-022-17583-4
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-022-17583-4
- Springer Nature Limited
This article is cited by
-
Automated design of protein-binding riboswitches for sensing human biomarkers in a cell-free expression system