Abstract
This paper addresses the issue of the sorption process on coal concerning propylene released from the source of coal heating in the deposit. In this study, the interaction between Polish coals and propylene molecules, as well as three other hydrocarbons (ethylene, ethane, and propane) with the application of a fixed-bed column, was investigated. The experimental results show that propylene adsorption was measurable under the experimental conditions. The differences in the amount of adsorbed propylene were predominately caused by various gas diffusion rates within the pore network associated with the molecular sieving effect. According to the experimental results, the influence of mesopores on propylene adsorption was significantly stronger than the share of micropores of the explored coals. The column tests demonstrated that the largest amount of propylene was adsorbed by coal with the highest value of pore diameter (6.48 nm) determined by nitrogen adsorption at 77 K. Under the experimental conditions, the influence of other hydrocarbons and a surface area on the quantity of the adsorbed gas was unnoticeable. This study provides an understanding of the behavior of some of the fire gases during the flow of the mixture through a heterogeneous structure of coal in the mine environment. The sorption of gases from multi-component mixture released during the self-heating of coal on carbon materials such as bituminous and lignite coals is poorly understood which provides the rationale for the topic of this work.
Similar content being viewed by others
Introduction
An endogenous fire is a very complex process occurring in the coal deposit conducive to heat accumulation and in zones hard to reach for people, which makes it difficult to detect the fire at an early in its development. The hazard of an endogenous fire arises due to coal self-oxidation process1,2,3. As a consequence of the contact with molecular oxygen from the air, which is entered the mine through the ventilation systems, coal undergoes low-temperature oxidation4,5,6. In the initial stage, oxidation takes place on the surface of the macropores and near the outer surface of the grains and fractures7. In the next phase, the oxygen molecules diffuse through increasingly narrower micropores into the inner surface of the pores where they undergo chemisorption on active surface centers. On account of the exothermic coal oxidation reaction, heat is released. If the heat emitted exceeds heat dissipated, the temperature within the coal mass and the oxidation reaction rate start to rise. At the same time, the unstable oxygen complexes are decomposed to produce the main gaseous compounds such as carbon dioxide, carbon monoxide and water vapor8,9. In recent years, the application of the Gas Chromatography – Flame Ionization Detector (GC-FID) allowed also to detect certain amounts (at the level of parts per million) of saturated (ethane and propane) and unsaturated (ethylene, propylene and acetylene) hydrocarbons in mine atmosphere occurring with the increase in coal temperature10,11. An endogenous fire is a process that can spread uncontrollably. The detection of this process in its initial development phase allows for the safe evacuation of employees, as well as for an effective control of the heating process and liquidation of the fire, often without stopping the extraction of coal12,13. One of the most common methods of identifying fire hazards in the mining sector is the method on basis of monitoring the composition of mine atmosphere in the air currents flowing in and out of the controlled area as well as at goafs and insulation dams14,15. Next, the results of the analyses are compared with the numerical model of fire gases emissions obtained under laboratory coal oxidation. However, the composition of the mixture released from the source of coal self-ignition may change because of the sorption phenomenon.
Coal is a natural sedimentary raw material with enhanced sorption properties. Both microscopic studies and the measurements of carbon dioxide or nitrogen sorption isotherms have confirmed that coal has a very extensive pore system with the share of very narrow pores (below 2 nm), mesopores (from 2 to 50 nm) and macropores (above 50 nm)16,17. The porous structure of coal determines its sorption capacity18,19. The larger amounts of gases are mainly adsorbed in the micropores or narrow mesopores due to the enormous inner surface area and a large number of active sites accessible for gas adsorption20,21. In contrast, large mesopores and macropores play an essential role in adsorbate transport22,23,24. A different degree of organic matter decomposition (aerobic or anaerobic) influenced the formation of various petrographic groups in the biochemical stage. It was observed that the share of individual pores in the pore space of coal also depends on the petrographic composition22,25,26. Individual groups of macerals are characterized by different porosity and pore structure. Studies have shown that inertinite macerals are more porous than the vitrinite macerals, but they are characterized by a lower share of micropores. The content of macerals in parent coals was also reported to be affecting the porous structure properties of thermally processed coals under pressurized conditions27,28. After the biochemical phase of material decomposition, further transformation occurs under the influence of geochemical factors such as pressure and temperature. At this time, the carbon content is steadily increasing, while oxygen, hydrogen and volatile matter content decreases. With the increase in carbon content, the share of micropores increases at the expense of mesopores and macropores. In high rank coals, porosity is primarily determined by the presence of micropores29.
In a number of published research papers30,31,32,33, the adsorption of gases most frequently used in fire risk assessment was discussed. In most of the studies the adsorption of a single gas on coal or the mixture of carbon dioxide and methane as an adsorbant was measured, and only in the context of methane recovery. However, under real conditions, the gases emitted from the point of self-ignition of coal constitute a multi-component gaseous mixture moving through the porous structure of coal. In study by Dudzińska34,35 the measurements were performed on degassed coal samples with the use of pure gases as adsorbants. A comparative analysis of the amounts of adsorbed gases indicated that propylene is sorbed in a larger amount than saturated hydrocarbons, carbon monoxide and hydrogen. The adsorption of propylene is on a comparable level with ethylene adsorption, while it is lower than acetylene. It was concluded that the higher preferential sorption of propylene, ethylene and acetylene over ethane and propane saturated hydrocarbons is the result of the interactions involving the π electrons of the multiple bond and the active centers present on the surface of coal. The authors of the works11,36,37,38 analyzed the coal sorption properties with the application of a fixed-bed column method and the multicomponent gaseous mixtures as adsorbant. The results showed a selective adsorption of mixture components. Additionally, the findings presented in these studies demonstrated that propylene is the gas which is the most sensitive to concentration changes in samples taken under real conditions. This gas reached the saturation state in the longest time and was sorbed in a larger amount in comparison to the remaining gases monitored. The higher reactivity of propylene is related to the strength of C–H bonds and the stability of the carbocation38. In these works, the porous structure parameters of coal samples were determined only on the basis of the nitrogen isotherm. Thus, the influence of pore size distribution below 2 nm on the amount of propylene adsorbed was not accurately analyzed, due to the limitation of the nitrogen adsorption method. Generally, in most of the above cited publications, it was also concluded that coal with high porosity, a low degree of metamorphism, a high value of specific surface area and the volume of pores determined by micropores and narrow mesopores, as well as high oxygen content sorbed the largest amounts of hydrocarbons.
In the literature, the studies on propylene adsorption and its behavior in porous materials are mainly performed in the context of the development of an alternative olefin separation technology in the petrochemical industry39,40,41. The current standard practice for the separation is a cryogenic distillation which is an energy intensive process40. A very promising solution is a separation technique based on the different diffusion rates of gases in the pore network or on the difference in the strength of the interactions between gas molecules in the mixture and the adsorbent surface41.
In this paper, the impact of the porous structure parameters of selected Polish coals on propylene sorption using a fixed-bed column was analyzed. The porous structure characterization was performed on the basis of nitrogen sorption isotherm at liquid nitrogen temperature and carbon dioxide sorption isotherm at 273 K with the application of the Autosorb iQ analyzer (Quantachrome Instruments, USA). It allowed to explore the impact of pore size distribution also at a range of narrow microporosity (from 0.45 to 1.45 nm) on the quantity of propylene adsorbed on coal, which has not been done in previous works42,43. The effects of the pore size distribution, the pore volume, the average pore diameters as well as the specific surface area of selected adsorbents on their sorption properties towards selected adsorbates were discussed in the aspect of the correct assessment of the fire hazard status in underground mines. There are very few published studies providing data on the effect of propylene flow in the coal pore network and its adsorption. The porous structure of various materials i.e. zeolites, active carbons or natural coals, plays a particularly important role in the gas diffusion mechanism in the pore network and the amount of gas uptake by the adsorbents. The most often reported critical parameter of the adsorbent sorption capacity is the size of the surface area and the number of active centers located on it. However, due to the heterogeneous structure of coals, the effect of the molecular sieving may play a more significant role in gas adsorption, especially when the size or shape of pores makes the penetration of adsorbates into the inner micropore structure of the adsorbents difficult. Such an effect can be more visible in the case of large size gas molecules, such as propylene (the kinetic diameter over 0.40 nm) and narrow micropores. In the study presented, the effect of a wide range of pores from 0.45 nm to 40 nm on the propylene sorption was tested.
Materials and methods
Adsorbents
Coal samples used in this study as adsorbents were obtained from active coal mines located in the Upper Silesia Coal Basin, Poland. The coals were ground in a laboratory mill to reduce the size of the samples and then sieved to range from 0.5 mm to 0.7 mm particle size. Each of the coal samples was stored in amber glass bottles for further adsorption tests. The characteristics of the adsorbents are given in Table 1.
Moisture, ash and volatile matter contents were done by using the determined with the use of automatic thermogravimetric analyzers LECO TGA 701 and MAC 500, while sulfur content was determined by an automatic analyzer TruSpec S by LECO44. The procedures for determining moisture and ash were applied according to standards ISO 1,171:2010 and ISO 589:2008, respectively; for volatile matter—ISO 562:2010, whereas for sulfur—ISO 334:1992. Carbon, hydrogen and nitrogen contents were measured with the application of an automatic analyzer TruSpec CHN by LECO in compliance with standards ISO 29,541:201045. Oxygen content was quantified by difference: 100%—moisture—ash—carbon—hydrogen – sulfur. Mineral matter and macerals groups (vitrinite, liptinite and inertinite) according to the method specified in standard ISO 7,404–3:2009.
The characterization of porous structure of coals tested was performed based on the measurements of nitrogen sorption at 77 K and carbon dioxide sorption at 273 K. The analyses were performed with the application of a gas sorption analyzer Autosorb iQ (Quantachrome Instruments, Boynton Beach, FL, USA). The specific surface area was determined with the use ofthe multi-point Brunauer–Emmett–Teller (BET) method46 and the nitrogen sorption isotherm data, andthe pore size distribution with the application of the density functional theory (DFT)47, while the total pore volume was calculated as the volume relevant for the relative pressure of 0.99. The narrow microporosity of the carbon materials tested in terms of pore area, volume and micropore size distribution was further characterized with the use the carbon dioxide sorption data and the Monte Carlo (MC) method 48. The results are given in Table 2.
The results of porous structure parameters obtained based on the nitrogen isotherm and the DFT method are given in Fig. 1, while the results calculated based on carbon dioxide isotherm and the Monte Carlo method are shown in Fig. 2.
Figure 3 illustrates the exemplary nitrogen isotherm for sample 3 with the hysteresis loop characteristic for mesoporous materials with irregular slit-like shape of pores49. The increase in the slope at the final p/po values is associated with the presence of a certain number of macropores.
Adsorbates
Three gaseous mixtures used in this study as adsorbates were provided by Air Products Industry Co., Ltd. The compositions of the mixtures are summarized in Table 3.
The composition of the inlet gas stream containing a mixture of ethylene, propane, ethane and propylene reflected the gases content in mixture liberated during the combustion of coal at temperatures above 373 K11,50.
Experimental setup and procedure
In this study, a fixed bed column method has been recognized as an efficient approach for investigating the adsorption process of propylene as one of the fire indicators generated during coal spontaneous combustion. The column method is mainly applied in the reduction of pollutant emissions, through the removal of ions by an ion-exchange bed or the separation of toxic organic compounds by adsorption on carbon materials51,52. The fixed-bed adsorption occurs in an open system where the adsorbate continuously passes through a column filled with adsorbent.
The dynamic adsorption tests of propylene on carbon materials were carried out using the laboratory equipment presented in Fig. 4.
The main characteristics of the fixed-bed column and the operating conditions are given in Table 4.
The measurement is based on a continuous flow of gaseous mixtures through a single glass column filled with crushed coal at a constant rate of 4.17 × 10–7 m3/s, calculated on the cross-section of an empty column. The column was kept at the temperature of 298 K by means of a heating cable wrapped around the entire length of the column, and managed by an external controller module. The sorption column was additionally protected by thermal coating to keep the temperature constant during the whole test. The pressure and flow rate at the inlet to the sorption column were controlled with the application of the ALICAT Scientific MS-50 gas flow regulator. The sampling at the outlet of the column was performed at regular time intervals: the first six samples were collected every 5 min, while the remaining samples were collected every 30 min until the end of the test. The adsorption process was stopped after 570 min.
The quantitative analysis of propylene in the mixture was performed by using a Hewlett-Packard-HP 6,890 GC System, Agilent Technologies Inc. gas chromatograph. The chromatograph was equipped with a packed column with alumina ype F1 with helium as a carrier gas and flame ionization detector (FID). This type of detector is sensitive to most hydrocarbons; therefore it is commonly used in industry53. The volume of gaseous sample introduced to the chromatograph was of 60 mL. The oven temperature was set at 323 K for five minutes and then the temperature increased at the rate of 308 K/min until it reached 403 K which was held for 2.5 min. The unknown propylene concentration in the mixture was calculated using a calibration curve established by measuring a series of reference gases with various concentrations fitted to the working range. The lowest concentration of propylene that could be reliably measured by this analytical method was 0.01 ppm.
Results and discussion
The effect of using five adsorbents with carbon content ranging from 63.98% to 86.19% on propylene adsorption from three mixtures M1, M2 and M3 is shown in Fig. 5. Column graphs in Fig. 5 illustrate the difference (ΔC = Co–Ct) between the propylene concentration at the inlet gas stream (Co) and at the outlet gas stream (Ct) of the column over a period of time, while the curves show the outlet propylene concentration at any given time.
The results show that the time in which the propylene concentration is equal to, or over 95% of the initial concentration in the measurement time was not reached. In the literature, this time is called saturation time in which a fixed-bed is no longer able to adsorb more gases48,54. From the point of view of fire hazard assessment, the saturation time provides information on how long the sorption phenomenon may occur and cause the decrease in the concentration of propylene in the underground atmosphere. As can be seen, at the end of the measurement (at 570 min), the differences ΔC = (Co–Ct) were in the range of 2.03–3.73 ppm (for mixtures M1 and M3) or 1.16–1.74 (for mixture M2), which corresponds to approx. 70–80% of the initial concentration. Under real conditions, the gas flow rate is lower than in the test because of the stresses imposed on the rock layer by the weight of the overlying material. As demonstrated in many works, with the decrease in the gas flow rate, the residence time of adsorbants in the column is prolonged55,56. It means that in underground mines, the time of reaching the 70–80% of the initial concentration can be much longer than that which was achieved in the study presented.
As can be observed in Fig. 5, almost all the curves showing the changes of outflow concentration of propylene at the top of the sorption column display a shape of a logarithm function, with the exception of the curves of samples 2 and 4 which constituted the column filling. The shape of the curves for these two samples was similar to a logistic function shape (a typical S-profile). For samples 1, 3 and 5, the time at which Ct/Co = 0.05 (called breakthrough time) was obtained much faster, within 10–15 min, than for samples 2 and 451. For samples 2 and 4, the breakthrough occurred 20–25 min after the start of the test. It means that propylene was adsorbed more effectively by the lower layers of the fresh samples 2 and 4 during the initial stage of the operations. In contrast, the immediate propylene breakthrough for samples 1, 3, and 5 may suggest that the gas was unable to pass through the narrow pores and to adsorb on the internal surface. After the breakthrough point, the curves showed a sharp increase because of the gradual exhausted of the fixed-bed. The coal mass in the column became less efficient in adsorbing the gas molecules. It was observed that in the time range of 60–90 min, the outlet gas concentration reached 40–50% of the initial concentration; the exception was sample 4 which showed only 20–30% of the initial concentration at this time. After the outlet propylene concentration reached 50–60%, the outflow gas concentrations from column started to rise very slowly, the growth was of the order of 10% or less. The flow of propylene through the pore system became more difficult. This slowdown was probably due to higher diffusion resistance caused by the adsorption process.
Figure 6 shows the ratio of propylene concentration leaving the sorption column at the end of the test (Ck) to the propylene concentration entering the column at the bottom of column (Co).
In Fig. 7, a maximum sorption capacity achieved by selected coals within the experiment time is presented.
As demonstrated in Figs. 6 and 7, sample 4 was characterized by the lowest values of the ratio in the range of 0.63–0.67 and showed the highest adsorption capacity, while sample 5 had the highest values of the ratio, of the order of 0.77–0.80, and sorbed the lowest amount of gas. Sample 4 has the highest values of the average pore diameter, and the largest share of mesopores of 2–5 nm diameter in pore volume and area (see Table 2 and Fig. 1). Coal sample 5 is not characterized by a porous structure as rich in mesopores as sample 4. In sample 5, the micropores of the pore size of 0.85–1.05 nm determined on the basis of the carbon dioxide adsorption, constituted approx. 76% of the micropores area and 32% of the micropores volume (see Fig. 2). The percentage of mesopores contribution to the porous structure of sample 5 was lower than for the remaining samples and ranged to around 18% in terms of surface area and over 40% when the pore volume is considered. The average pore diameter for sample 5 was the smallest of all in this study and equaled 3.67 nm. The pore size distribution data for narrow micropores based on the carbon dioxide sorption at 273 K (see Fig. 2) for samples 4 and 5 is similar. The difference was reflected in a 10% higher share of pores of 0.85–1.45 nm diameter and a 23–25% lower share of pores of the diameter from 0.45 to 0.85 nm in the volume and area of pores for sample 5 than for sample 4. The results revealed the higher importance of pores with a diameter size over 2 nm over the micropores of the size below 1.45 nm for the propylene uptaken by the coal adsorbents. As shown in Figs. 6 and 7, sample 3 has higher values of the Ck/Co ratio and lower sorption capacity than sample 4. This coal sample is characterized by lower the average pore size and the share of 2–5 nm pores compared to sample 4. In sample 3, pores of 2–5 nm diameter contribute to about 50% of pore volume (see Fig. 1).
Sample 1 and 2, characterized by comparable values of physical and chemical parameters (see Table 1), had different values of the Ck/Co ratio and sorbed different amounts of propylene. The values obtained for sample 2 may be attributable to the higher value of inertinite maceral group. The inertinite structure is mostly mesoporous or macroporous21. However, in Figs. 1 and 2, it can be observed that samples 1 and 2 show a similar pore size distribution in terms of the area and volume of pore quantified based on nitrogen and carbon dioxide sorption isotherms. The share of pores with a diameter size of 2–5 nm and 1–2 nm in samples 1 and 2 was the highest and amounted to about 40% (by volume) for both ranges. In the above samples, the pores of the 0.65–0.85 nm diameter constituted a larger group (see Fig. 2) which involved approximately 35–36% of the micropore area and 44–45% of the micropore volume. A multimodal pore structure of coal makes that carbon materials may behave as a molecular sieve and block the gases with larger size pass through the micropores and mesoporous channels. The differences between the samples may result from a slightly higher value of the average pore diameter for sample 2. It was noticed that although the surface area of samples 1 and 2 is 2 times (based on carbon dioxide isotherm) and 5 times (based on nitrogen isotherm) larger than that of all the other samples, these samples showed lower propylene sorption capacity (see Table 2) than sample 4.
The various values of the Ck/Co ratio as well as various amounts of adsorbed propylene obtained for all the selected samples can be caused by different diffusion rates in the pore structure. In coal characterized by large pore diameters, easier flow of propylene molecules leads to the higher adsorption of the gas. However, in coal characterized by a small pore size, propylene molecules can be trapped in narrow pores due to large-size (0.45 nm) and partially block the access of other propylene molecules to the adsorption sites on the inner surface. Besides, propylene flowing through the porous structure of coal may undergo multilayer adsorption, which may cause the reduction of the pore diameter to smaller sizes57. As a result of the multilayer adsorption, the effective pore size may approach the size of a propylene molecule. Based on the results, it can be implied that the relatively high values of pore diameter and the higher share of mesopores in samples 3 and 4 enabled the diffusion of propylene into inner pores and increased the access to more sorption sites on the coal surface. The positive correlation between the pore diameter and sorption capacity was more visible in the case of mixture 1, as can be observed in Fig. 7. Gas transport through porous materials can be controlled by various mechanisms. In pores with sizes larger than the adsorbed gas molecules, the diffusion process will occur mainly in accordance with the Knudsen mechanism in which the molecules collide with the pore walls58. In pores with comparable or smaller sizes than the adsorbate diameter, the gas will move both through the collisions of molecules with pore walls, and along the sorbent surface where gas transport is driven by surface energy heterogeneity. Thus, in the case of mesopores the transport of molecules depends on their molecular weight, while in micropores it depends on the size and shape of the diffusing molecule.
The results presented in Figs. 6 and 7, it can be found that the presence of propane, ethane and ethylene in the mixture caused a slight change of the Ck/Co ratio. The increase in the values of the Ck/Co ratio for samples 3 and 4 could be due to the fact that in the first stage of the process, smaller particles, i.e. ethylene, are early adsorbed. Larger adsorbed particles need more time to reach the active centers on the inner surface, the number of which has decreased as a result of the earlier adsorption of ethylene. Besides, the ethylene multilayer adsorption will not cause such a significant reduction in the pore diameter as in the case of propylene. A 50% lower concentration of propylene in mixture M2 than in M1 causes that fewer molecules are trapped in coal porous structure resulting in an easier access to more active sites. Interestingly, the share of propane, ethane and ethylene in the mixture led to the rise of propylene adsorption (see Fig. 7) on samples 1 and 2 with the highly developed surface areas. The finding indicates that the presence of other hydrocarbons leads to the increase in the propylene diffusion into the deep inner surface. However, this issue requires further research.
The issue of propylene sorption on coal from a multi-component mixture released during thermal coal oxidation is important for the correct assessment of the degree of endogenous fire risk in underground mines. The porous structure characterization indicated that the e porous structure of coal provides good storage capacity and an ideal transport system for migrating gases. The consequence of such a diversified coal structure is the possibility of migration of gases emitted from the fire center through the coal structure and sorption at adsorption centers. The results of this study showed that the concentration of propylene can be reduced by over 50%. The accumulation of fire gases in the pore structure of coal may result in lowering the value of their concentrations in gaseous samples collected at stations of early detection of mine fires. Numerous studies of the process of self-ignition of coal have shown that with the development of a fire, characteristic gases such as carbon monoxide, carbon dioxide, hydrogen, propylene and ethylene begin to appear in the mine atmosphere59,60. The concentration of these gases rises up with the increases in coal temperature. The underestimation of concentration resulting from gas sorption can lead to an incorrect assessment of the development of fire level and a life hazard to employees.
Conclusion
In this work, all selected coals had a potential to adsorb propylene from the mixtures. A complete gas saturation of the fixed-bed was not reached under experimental conditions due to the slow velocity gas flow. The slowdown of the gas flow was observed after reaching 50–60% of the initial concentration at the exit of the column. It was found that the overall sorption process was controlled through the gas diffusion rate in the pore network. According to the results, the amount of hydrocarbon uptake during the flow through the fixed bed column was correlated with the average pore diameter of coal. This relation was more visible in the mixture of pure propylene and nitrogen in the inlet of column. The highest propylene adsorption capacity values of 1.59∙10–3 mg/g and 1.70∙10–3 mg/g were obtained for sample 4 with the highest value of the average pore size of 6.48 nm. It was found that the samples of higher share of mesopores and a higher value of the average pore diameter were more efficient in propylene sorption. Even though the higher specific surface area means a large number of active centers and it is generally desired in the selection of the adsorbents, it could be inferred that larger pore sizes are more beneficial for the gas flow into the narrow pores of coals, and, therefore advantageous for propylene adsorption on the carbon materials. It was noticed that the presence of ethylene, ethane and propane in the mixture did not affect significantly the propylene uptake.
The experimental results imply that the concentration of propylene in the mine atmosphere may be lower than the gas concentration in model tests performed in laboratory where the sorption process is not taken into account. In underground conditions. The long retention time and high sorption of propylene on coal may be significant for the detection of endogenous fire on the basis of the concentration of this hydrocarbon. Therefore, the use of propylene as a fire indices reveal justifiable limitations, which has been proven in the course of the experimental works; especially, in coals with a high share of mesopores where easier propylene diffusion will lead to higher gas adsorption on coal surface. The research on the role of pore structure in propylene behavior in porous media can be also helpful during the design of high-performance adsorbents used in the propane/propylene separation.
References
Onifade, M. & Genc, B. Spontaneous combustion of coals and coal-shales. Int. J. Min. Sci. Technol. 28, 933–940 (2018).
Deng, J. et al. Thermal analysis of spontaneous combustion behavior of partially oxidized coal. Process Saf. Environ. Prot. 104, 218–224 (2016).
Singh, R. V. K. Spontaneous heating and fire in coal mines. Procedia Eng. 62, 78–90 (2013).
Yuan, L. & Smith, A. C. The effect of ventilation on spontaneous heating of coal. J. Loss Prevent. Proc. 25, 131–137 (2012).
Gbadamosi, A. R., Onifade, M., Genc, B. & Rupprecht, S. Spontaneous combustion liability indices of coal. Combust. Sci. Technol. 13, 1–13 (2020).
Onifade, M., Genc, B. & Wagner, N. Influence of organic and inorganic properties of coal-shale on spontaneous combustion liability. Int. J Min. Sci. Technol. 29, 851–857 (2019).
Pone, J. D. N. et al. The spontaneous combustion of coal and its by-products in the Witbank and Sasolburg coalfields of South Africa. Int. J. Coal Geol. 72, 124–140 (2007).
Chećko, J., Urych, T., Magdziarczyk, M. & Smoliński, A. Resource Assessment and Numerical Modeling of CBM Extraction in the Upper Silesian Coal Basin Poland. . Energies 13(9), 2153. https://doi.org/10.3390/en13092153 (2020).
Zhang, Y. et al. Modes and kinetics of CO2 and CO production from low-temperature oxidation of coal. Int. J. Coal Geol. 140, 1–8 (2015).
Stracher, G. B. Gases generated during the low-temperature oxidation and pyrolysis of coal and the effects on methane-air flammable limits. Coal Peat Fires Global Perspect. 2019, 157–171 (2019).
Wojtacha-Rychter, K. & Smoliński, A. The interaction between coal and multi-component gas mixtures in the process of coal heating at various temperatures: an experimental study. Fuel 213, 150–157 (2018).
Onifade, M., Genc, B. & Bada, S. Spontaneous combustion liability between coal seams: a thermogravimetric study (Int. J Min. Sci, Technol, 2020) ((In Press)).
Onifade, M. & Genc, B. A review of research on spontaneous combustion of coal (Int. J Min. Sci, Technol, 2020) ((In Press)).
Thakur, P. Spontaneous combustion of coal. Adv. Mine Ventil. 140, 345–362 (2019).
State Mining Authority. Assessment of the state of work safety, mining rescue and safety in connection with mining and geological activities in 2018. Katowice (2019).
Zhang, J., Wei, C., Yan, G. & Lu, G. Energ. Explor. Exploit. 37, 251–272 (2018).
Liu, Q. et al. Experimental observations of matrix swelling area propagation on permeability evolution using natural and reconstituted samples. J. Nat. Gas Sci. Eng. 34, 680–688 (2016).
Liu, Y., Zhu, Y., Liu, S. & Li, W. A hierarchical methane adsorption characterization through a multiscale approach by considering the macromolecular structure and pore size distribution. Mar. Petrol. Geol. 96, 304–314 (2018).
Liu, Z., Zhang, Z., Choi, S. & Lu, Y. Surface properties and pore structure of anthracite, bituminous coal and lignite. Energies 11, 1502 (2018).
Yue, J. et al. Investigation of pore structure characteristics and adsorption characteristics of coals with different destruction types. Adsorpt. Sci. Technol. 37, 623–648 (2019).
Bakshi, T., Prusty, B. K., Pathak, K. & Pal, S. K. Pore characteristics of Damodar valley shale and their effect on gas storage potential. J. Petrol. Sci. Eng. 162, 725–735 (2018).
Nie, B., Liu, X., Yang, L., Meng, J. & Li, X. Pore structure characterization of different rank coals using gas adsorption and scanning electron microscopy. Fuel 158, 908–917 (2015).
Cai, Y. et al. Pore structure and its impact on CH4 adsorption capacity and flow capability of bituminous and subbituminous coals from Northeast China. Fuel 103, 258–268 (2013).
Qi, L., Tang, X., Wang, Z. & Peng, X. Pore characterization of different types of coal from coal and gas outburst disaster sites using low temperature nitrogen adsorption approach. Int. J. Min. Sci. Technol. 27, 371–377 (2017).
Duan, X. Q., Qu, J. W. & Wang, Z. N. Pore structure of macerals from a low rank bituminous. J. China Univ. Min. Technol. 38, 224–228 (2009).
Zhao, J. et al. Effects of pore structures of different maceral compositions on methane adsorption and diffusion in anthracite. App. Sci. 9, 5130 (2019).
Howaniec, N. Development of porous structure of lignite chars at high pressure and temperature. Fuel Process Technol. 154, 163–167 (2016).
Howaniec, N. The effects of pressure on coal chars porous structure development. Fuel 172, 118–123 (2016).
JG Speight 2015 Handbook of Coal Analysis 2 Marcel Dekker New York
Dudzińska, A. & Cygankiewicz, J. Analysis of adsorption tests of gases emitted in the coal self-heating process. Fuel Process. Technol. 137, 109–116 (2015).
Baran, P., Cygankiewicz, J., Krzyżanowski, A. & Zarębska, K. Sorption of saturated and unsaturated hydrocarbons on selected coal sample from the Pniówek mine. Geol. Geophys. Environ. 39, 341–349 (2013).
Busch, A., Gensterblum, Y., Krooss, B. M. & Siemons, N. Investigation of high-pressure selective adsorption/desorption behavior of CO2 and CH4 on coals: an experimental study. Int. J. Coal Geol. 66, 53–68 (2006).
Dudzińska, A. Analysis of sorption and desorption of unsaturated hydrocarbons: ethylene, propylene and acetylene on hard coals. Fuel 246, 232–243 (2019).
Dudzińska, A. Sorption properties of hard coals with regard to gases present in the mine atmosphere. J. Earth Sci. 28, 124–130 (2017).
Gogola, K., Rogala, T., Magdziarczyk, M. & Smoliński, A. The mechanisms of endogenous fires occurring in extractive waste dumping facilities. Sustainability 12, 2856. https://doi.org/10.3390/su12072856 (2020).
Wojtacha-Rychter, K. & Smoliński, A. E3S Web Conf. 19(101010), 1–6 (2017).
Wojtacha-Rychter, K. & Smoliński, A. Multi-component gas mixture transport through porous structure of coal. Fuel 233, 37–44 (2018).
Wojtacha-Rychter, K. & Smoliński, A. Selective adsorption of ethane, ethylene, propane and propylene in flammable gas mixtures on different coal samples and implications for fire hazard assessments. Int. J. Coal Geol. 202, 38–45 (2019).
Li, K. et al. Zeolitic imidazolate frameworks for kinetic separation of propane and propene. J. Am. Chem. Soc. 131, 10368–10369 (2009).
Liu, J. et al. A new carbon molecular sieve for propylene/propane separations. Carbon 85, 201–211 (2015).
Iacomi, P. et al. Role of structural defects in the adsorption and separation of C3 hydrocarbons in Zr-Fumarate-MOF (MOF-801). Chem. Mater. 31, 8413–8423 (2019).
Wojtacha-Rychter, K., Howaniec, N. & Smoliński, A. The effect of coal grain size on the sorption of hydrocarbons from gas mixtures. Int. J. Energy Res. 43, 3496–3506 (2019).
Wojtacha-Rychter, K. & Smoliński, A. A study of dynamic adsorption of propylene and ethylene emitted from the process of coal self-heating. Sci. Rep. 9, 1–14 (2019).
Howaniec, N. Combined effect of pressure and carbon dioxide activation on porous structure of lignite chars. Materials 12, 1326 (2019).
Wojtacha-Rychter, K. & Smoliński, A. A study of dynamic adsorption of propylene and ethylene emitted from the process of coal self-heating. Sci. Rep. 9, 18277 (2019).
Brunauer, S., Emmett, P. & Teller, E. Adsorption of gases in multimolecular layers. J. Am. Chem. Soc. 60, 309–319 (1938).
Lowell, S., Shields, J. E., Thomas, M.A., & Thommes, M. Characterization of porous solids and powders: surface. Area, pore size and density (The Netherlands, 2004).
Bottani, E., & J., Tascon, J. M. D. Adsorption by carbons (Oxford, UK, 2008).
Tang, X. et al. The effect of the variation in material composition on the heterogeneous pore structure of high-maturity shale of the Silurian Longmaxi formation in the southeastern Sichuan Basin. China. J. Nat. Gas Sci. Eng. 23, 464–473 (2015).
Cygankiewicz J. Forecasting coal self-ignition process in mine undergrounds (Poland, 2018).
Patel, H. Fixed-bed column adsorption study: a comprehensive review. Appl. Water Sci. 9, 1–17 (2019).
Karunarathne, H. D. S. S. & Amarasinghe, B. M. W. P. K. Procedia Eng. 34, 83–90 (2013).
Chaulya, S. K., & Prasad, G. M. Gas Sensors for Underground Mines and Hazardous Areas in Sensing and Monitoring Technologies for Mines and Hazardous Areas (India, 2016).
Chatterjee, A. & Schiewer, S. Biosorption of cadmium(II) ions by citrus peels in a packed bed column: effect of process parameters and comparison of different breakthrough curve models. Clean (Weinh) 39, 874–881 (2011).
Radhika, R., Jayalatha, T., Rekha Krishnan, G., Jacob, S. & Rajeev, R. Process Saf. Environ. Prot. 117, 350–362 (2018).
Marzbali, M. H. & Esmaieli, M. Fixed bed adsorption of tetracycline on a mesoporous activated carbon: experimental study and neuro-fuzzy modeling. J. Appl. Res. Technol. 15, 454–463 (2017).
Nakamura, K. & Matsumoto, K. Protein adsorption properties on a microfiltration membrane: a comparison between static and dynamic adsorption methods. J. Membr. Sci. 285, 126–136 (2006).
Chen, J., Hou, J., Wang, R. & Hui, Y. Adv. Mech. Eng. 9, 168781401772185 (2017).
Zhu, H., Chang, M. & Wang, H. Study on primal CO gas generation and emission of coal seam. Int. J. Min. Sci. Technol. 27, 973–979 (2017).
Liang, Y., Zhang, J., Wang, L. & Luo, H. Forecasting spontaneous combustion of coal in underground coal mines by index gases: A review. J. Loss Prev. Process. Ind. 57, 208–222 (2019).
Acknowledgements
This work was supported by the Ministry of Science and Higher Education, Poland [Grant No. 11133069].
Author information
Authors and Affiliations
Contributions
K.W.-R. and A.S. conceived and designed of the study; K.W.-R., N.H. collected the data; K.W.-R. and A.S. analyzed the data, K.W.-R., N.H. and A.S interpreted and wrote the paper. All authors reviewed the manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Wojtacha-Rychter, K., Howaniec, N. & Smoliński, A. Effect of porous structure of coal on propylene adsorption from gas mixtures. Sci Rep 10, 11277 (2020). https://doi.org/10.1038/s41598-020-67472-x
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-020-67472-x
- Springer Nature Limited
This article is cited by
-
Pore Fractal Dimensions of Bituminous Coal Reservoirs in North China and Their Impact on Gas Adsorption Capacity
Natural Resources Research (2021)