Abstract
We demonstrate an on-demand source of microwave single photons with 71–99% intrinsic quantum efficiency. The source is narrowband (300 kHz) and tuneable over a 600 MHz range around 5.2 GHz. Such a device is an important element in numerous quantum technologies and applications. The device consists of a superconducting transmon qubit coupled to the open end of a transmission line. A π-pulse excites the qubit, which subsequently rapidly emits a single photon into the transmission line. A cancellation pulse then suppresses the reflected π-pulse by 33.5 dB, resulting in 0.005 photons leaking into the photon emission channel. We verify strong antibunching of the emitted photon field and determine its Wigner function. Non-radiative decay and 1/f flux noise both affect the quantum efficiency. We also study the device stability over time and identify uncorrelated discrete jumps of the pure dephasing rate at different qubit frequencies on a time scale of hours, which we attribute to independent two-level system defects in the device dielectrics, dispersively coupled to the qubit. Our single-photon source with only one input port is more compact and scalable compared to standard implementations.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Introduction
The single photon—the fundamental excitation of the electromagnetic field—plays a key role in quantum physics and can find practical application in quantum sensing1, communication2, and computing3,4,5. Recently, considerable progress has been made in the generation of optical photons, e.g. by using quantum dots6,7,8. However, in the microwave domain, the much smaller photon energy introduces many constrains for the realization of single-photon sources; for instance, operation at millikelvin temperatures is necessary to avoid thermal generation of photons. Narrowband microwave single photons are essential for precise interactions with circuits exhibiting a shaped energy structure, such as coplanar resonators9, three-dimensional cavities10, and acoustic-wave resonators11,12, which can be used as quantum memories.
Superconducting quantum circuits are suitable for the implementation of on-demand microwave photon sources. So far, several different methods have been used. The first method is based on a qubit coupled to a resonator13,14,15, where the source bandwidth is limited by the linewidth of the resonator. Secondly, in refs. 16,17,18, single photons are generated due to inelastic Cooper-pair tunneling. This type of source has a high emission rate, but it cannot generate a superposition of vacuum and a single-photon Fock state. Thirdly, a single-photon generator based on emission from a qubit into a waveguide requires proper engineering of the asymmetric couplings to the control and emission channels19,20,21,22. Finally, shaped single photons emitted from a qubit located near the end of a transmission line with a tunable-impedance termination23 were demonstrated in experiment24. None of these experiments included a thorough study of the photon leakage of the excitation pulse from the control to the emission channel, which affects the purity of the single-photon.
In this work, we implement a theoretical proposal from ref. 23: a frequency-tunable qubit is capacitively coupled to the end of an open transmission line25,26. Only a single channel exists in our system, so that the qubit, excited by a π-pulse, can only release a single photon back to the input. We cancel the π-pulse, after its interaction with the qubit, by interfering it with another, phase-shifted pulse and show a photon leakage 0.5% of a photon from the excitation pulse. The intrinsic quantum efficiency of our single-photon source is 71–99% over a tuneable frequency range of 600 MHz around 5.2 GHz, which is about 1600 times larger than the single-photon linewidth (300 kHz). This bandwidth is more than 20 times narrower than that of the tuneable microwave single-photon sources reported in refs. 16,17,18,20,21,22,24.
Different from refs. 16,17,18, our single-photon source allows to generate a superposition of vacuum and a single-photon Fock state. Moreover, compared to other results with more than one input ports20,21,22,24, our single-port single-photon source does not require engineering of the asymmetric couplings on chip and is more compact and scalable as the number of sources increase.
Importantly, the intrinsic quantum efficiency—the fidelity only due to the emitter coherence—can be limited by both the pure dephasing rate and the non-radiative decay rate of the emitter. It is important to understand the noise mechanisms determining these rates in order to make further improvements. We systematically study the limitation of the intrinsic quantum efficiency and the temporal fluctuations of the single-photon source over 136 h. The result shows that both non-radiative decay and 1/f flux noise can affect the quantum efficiency from different types of two-level systems (TLSs). In addition, we also characterize the fluctuations of the pure dephasing rate due to dispersively coupled TLS defects with a narrow linewidth, which can lead to a decrease of the quantum efficiency by up to 60%.
Results
Experimental setup and procedure for single-photon emission
Our device consists of a magnetic-flux-tunable Xmon-type transmon qubit, capacitively coupled to the open end of a one-dimensional coplanar-waveguide transmission line. This zero-current boundary condition behaves as a mirror for the incoming microwave radiation. The corresponding simplified circuit diagram is shown in Fig. 1a. An asymmetric beam splitter, implemented by a 20 dB directional coupler, is connected to the sample to provide channels for qubit excitation and pulse cancellation. The circuit is made of aluminum on a silicon substrate, and is fabricated with a standard lithography process27. The sample is characterized at T = 10 mK with its parameters shown in Table 1.
As shown in Fig. 1a, we send a pulse to the input port of the directional coupler with the amplitude ain(t)/A, where A = 0.1 is the attenuation from the −20 dB directional coupler. Then, ain(t) is the corresponding amplitude of the pulse at the qubit. The output field at the qubit, using the standard input-output relation, is \({a}_{{{{{{\rm{out}}}}}}}^{{{{{{\rm{q}}}}}}}(t)={a}_{{{{{{\rm{in}}}}}}}(t)-i\sqrt{{{{\Gamma }}}_{{{{{{\rm{r}}}}}}}}{\sigma }_{-}(t)\)23,28, where σ−(t) is the emission operator of the qubit. By adding another pulse β(t)/A to the cancellation port of the directional coupler, we have \({a}_{{{{{{\rm{out}}}}}}}(t)={a}_{{{{{{\rm{out}}}}}}}^{{{{{{\rm{q}}}}}}}(t)+\beta (t)\) at the output of the directional coupler. When β(t) = −ain(t), we have \({a}_{{{{{{\rm{out}}}}}}}(t)=-i\sqrt{{{{\Gamma }}}_{{{{{{\rm{r}}}}}}}}{\sigma }_{-}(t)\) (the small red pulse). This means we obtain a single photon if ain(t) is a π-pulse, and a superposition of vacuum and a single-photon Fock state if ain(t) is a π/2-pulse.
We adjust the external flux to zero (Φ = 0) so that the qubit reaches its highest frequency ω01. We then send a calibrated Gaussian pulse \(\propto \exp (-{t}^{2}/2{\xi }^{2})\) with ξ = 20 ns which is on resonance with the qubit, so that it acts as a π-pulse. We measure the output field using a traveling-wave parametric amplifier (TWPA)29 followed by a high electron mobility transistor amplifier (HEMT) (Fig. 7). Both quadratures of the signal output from the directional coupler, with and without the cancellation, are amplified and recorded by a digitizer (not shown) as a voltage V(t) = I(t) + iQ(t). The voltage is then normalized by the system gain from the on-resonance Mollow triplet30,31,32. After averaging, the corresponding photon number at the qubit is defined as
where t0 and t1 denote when the signal starts and ends, respectively. Note that for the qubit emission, t0 is the time corresponding to the maximal amplitude of the emission. 〈VN〉 is the averaged system voltage noise and Z0 ≈ 50 Ω is the waveguide impedance.
Figure 1b shows the power of the input π-pulse as a function of time. The black line indicates the power of the input pulse at the sample after the gain calibration when the qubit is tuned away, while the blue one corresponds to the residual pulse after cancellation. The result shows a 33.5 dB suppression of a π-pulse in power due to the cancellation, resulting in a photon leakage of \({n}_{{{{{{\rm{leak}}}}}}}^{{{{{{\rm{meas}}}}}}}=0.0049\), according to Eq. (1). In Fig. 1c, we also measure the coherent emission (red line) from the qubit decay after a π/2-pulse and fit the data to an exponential curve (black) with a decay rate Γ2/(2π) = 193 ± 4 kHz. By taking the integral over time with Eq. (1) starting from t0 = 252 ns, we obtain the photon numbers \({n}_{{{{{{\rm{q}}}}}}}^{{{{{{\rm{meas}}}}}}}\approx 0.173\) for the qubit emission. This agrees well with the formula Γr/8Γ2 = 0.1795 derived below. We notice that \({n}_{{{{{{\rm{q}}}}}}}^{{{{{{\rm{meas}}}}}}}\) is less than 0.5 since we just measure the coherent part of the qubit emission.
The leakage from the excitation pulse can also be estimated without calibrating the system gain as follows. The driven qubit generates a voltage amplitude of Vq(t) = i2ω01Z0Ccdσ−(t)20, where d is the qubit dipole moment, and Cc represents the coupling capacitance between the qubit and the transmission line. The radiative decay rate is given by \({{{\Gamma }}}_{{{{{{\rm{r}}}}}}}={S}_{{{{{{\rm{v}}}}}}}(\omega ){({C}_{{{{{{\rm{c}}}}}}}d)}^{2}/{\hslash }^{2}\) with Sv(ω) = 2\(\hslash\) ω01Z0 being the spectral density of the voltage quantum noise in the transmission line where we ignore the effect from the thermal noise inside the waveguide since \(\hslash\)ω01 ≫ kBT. Therefore, the corresponding emission power from the qubit is \(| {V}_{{{{{{\rm{q}}}}}}}(t){| }^{2}/(2{Z}_{0})=\hslash {\omega }_{01}{{{\Gamma }}}_{{{{{{\rm{r}}}}}}}| {\sigma }_{-}(0){| }^{2}{e}^{-2{{{\Gamma }}}_{2}t}\) where we have \({\sigma }_{-}(t)={\sigma }_{-}(0){e}^{-{{{\Gamma }}}_{2}t}\). By taking the integral over time, the photon number is nq = Γr/(2Γ2)∣σ−(0)∣2 = Γr/8Γ2. Combining the values of Γr and Γ2 in Table 1, the leakage from the π-pulse is \({n}_{{{{{{\rm{leak}}}}}}}={n}_{{{{{{\rm{leak}}}}}}}^{{{{{{\rm{meas}}}}}}}/{n}_{{{{{{\rm{q}}}}}}}^{{{{{{\rm{meas}}}}}}}\times {n}_{{{{{{\rm{q}}}}}}}\approx 0.005\). In reality, ∣σ−(0)∣ < 0.5 due to the small emission during a π/2-pulse. Here, we ignore this since our pulse length is much shorter than the qubit lifetime. We emphasize that the amplitude of the canceled pulse in Fig. 1b, c was minimized by adjusting the amplitude of the cancellation pulse, the phase difference between the input and the cancellation pulse and compensating the time delay between these two pulses. Compared to directly measuring the qubit emission power after a π-pulse, we take an advantage of the coherent emission after a π/2-pulse so that the system noise can be averaged out with much fewer averages.
Qubit operation
Next we vary the pulse length τ, and measure the integral of free-decay traces such as the one in Fig. 1c, normalized to the number of points in the trace. In order to maximize the signal, we digitally rotate the integrated value into the I quadrature. Meanwhile, we also record the second moment of the emitted field which corresponds to the emitted power 〈P〉 = 〈(I2 + Q2)〉. Figure 2 shows the Rabi oscillations of 〈I〉 and 〈P〉 with pulse lengths up to 1.4 μs. The signal is averaged over 1.28 * 104 repetitions. The background offset from the system noise is removed from each data point of the power oscillation. The clear oscillatory pattern in the figure is a manifestation of the coherence of photons emitted by the qubit. By solving the Bloch equations we obtain
where Γ1 is the relaxation rate of the qubit and Ω is the Rabi frequency, Γs = (Γ1 + Γ2)/2, \({{{\Omega }}}_{{{{{{\rm{m}}}}}}}=\sqrt{{{{\Omega }}}^{2}-{({{{\Gamma }}}_{1}-{{{\Gamma }}}_{2})}^{2}/4}\), \({B}_{1}={{{\Omega }}}_{{{{{{\rm{m}}}}}}}-({{{\Gamma }}}_{1}^{2}-{{{\Gamma }}}_{2}^{2})/(4{{{\Omega }}}_{{{{{{\rm{m}}}}}}})\), \({B}_{2}={{{\Gamma }}}_{{{{{{\rm{s}}}}}}}/{{{\Omega }}}_{{{{{{\rm{m}}}}}}}=\cot {\theta }_{2}\) and \({{{\Gamma }}}_{1}/{{{\Omega }}}_{{{{{{\rm{m}}}}}}}\approx \tan {\theta }_{1}\). Since 〈I〉 ∝ 〈σy〉 and 〈P〉 ∝ 1 + 〈σz〉, we take Eq. (2) to fit the data to obtain Γs/2π = 316 ± 6 kHz and θ2 + θ1 = (0.498 ± 0.004)π. The phase difference indicates that the measured radiation is not from a coherent state in which the power and amplitude would oscillate in phase.
To demonstrate that our device indeed is a single-photon source we extract the second-order correlation function g(2)(0) and we reconstruct the Wigner function W(α)33. We send either a π-pulse or a π/2-pulse to excite the qubit. With an appropriate mode-matching filter with an exponential decay, we obtain the quadrature histograms of the measured single-shot voltages normalized by the gain value. The single-shot measurement is repeated up to 2.56 * 107 times. By then subtracting the reference values measured in the absence of the pulse, as outlined for example in ref. 34, we extract the moments of the photon mode a. Figure 3a shows the moments ∣〈a〉∣, 〈a†a〉 and \(\langle {({a}^{{{\dagger}} })}^{2}{a}^{2}\rangle\) of the qubit emission after a π-pulse and a π/2-pulse, respectively. The first and second-order moments are 0.036 ± 0.001 and 0.618 ± 0.003 for a π-pulse, and 0.399 ± 0.035 and 0.337 ± 0.002 for a π/2-pulse. The second order of moments shows that the overall quantum efficiencies at the maximum qubit frequency are 61.8% for a single-Fock state \(\left|1\right\rangle\) after a π-pulse, and 67.4% for a superposition state \((\left|0\right\rangle +\left|1\right\rangle )/\sqrt{2}\) after a π/2-pulse. In our case, the maximum photon number is just one so that we only need to consider up to the fourth order of the moments corresponding to two photons.
The moments we extract differ from the theoretically expected 〈a†a〉 = 1 for the Fock state and ∣〈a〉∣ = 0.5 for the superposition state. The numerical result from simulating the dynamics of the qubit by using QuTip35 shows that the population of the first excited level of our qubit is given by the density matrix element ρ11 = 0.93 after a π-pulse with ξ = 20 ns, and ∣σ−∣ = 0.44 after a π/2-pulse with ξ = 20 ns. The normalized filter for the mode matching is \(f(t)=\sqrt{{{{\Gamma }}}_{1}}{e}^{-{{{\Gamma }}}_{1}/2t}\), leading to 〈a†a〉 = Γr/Γ1 and \(| \langle a\rangle | =2\sqrt{{{{\Gamma }}}_{{{{{{\rm{r}}}}}}}{{{\Gamma }}}_{1}}/(2{{{\Gamma }}}_{2}+{{{\Gamma }}}_{1})\). In summary, we have 〈a†a〉 = 0.93*Γr/Γ1 and \(\langle a\rangle =0.44* 2\sqrt{{{{\Gamma }}}_{{{{{{\rm{r}}}}}}}{{{\Gamma }}}_{1}}/(2{{{\Gamma }}}_{2}+{{{\Gamma }}}_{1})\). Combining the decay rates in Table 1 and assuming that the pure dephasing rate is zero (Fig. 4b) at the maximum qubit frequency (Φ = 0), we get 〈a†a〉 = 0.67 and ∣〈a〉∣ = 0.36, which are close to our measured results. From this discussion, we can conclude that the non-radiative decay is the main factor that limits the quantum efficiency of our single-photon source at the flux sweet spot, and the overall quantum efficiency are limited by both the imperfect qubit excitation and the qubit coherence.
Of particular interest is the normalized zero-time-delay intensity correlation function \({g}^{(2)}(0)=\langle {({a}^{{{\dagger}} })}^{2}{a}^{2}\rangle /{\langle {a}^{{{\dagger}} }a\rangle }^{2}\). Its values of 0 ± 0.0139 and 0 ± 0.0264 for π and π/2-pulses show an almost complete antibunching of the microwave field, demonstrating that the output is almost purely a single photon. To further demonstrate that our source is nonclassical, in Fig. 3b, we reconstruct the Wigner function from the relation \(W(\alpha )=(2/\pi ){{{{{\rm{Tr}}}}}}[\hat{D}(\alpha )\rho {\hat{D}}^{{{\dagger}} }(\alpha )\hat{{{\Pi }}}]\), by using a maximum likelihood method34,36, where \(\hat{D}(\alpha )\) is the displacement operator with a coherent state α, \(\hat{{{\Pi }}}\) is the parity operator and ρ is the extracted density matrix of the filtered output from the different orders of moments.
Besides the photon leakage, there are a number of different properties that are important for proper operation of the single-photon source, such as frequency tunability, quantum efficiency, stability, bandwidth and repetition rate. In the following paragraphs we study and evaluate these quantities for our single-photon source.
Bandwidth, repetition rate, and tunability
The repetition rate for our source is limited by the coupling strength between the qubit and the transmission line which can be varied over a wide range by design. For our sample the relaxation rate at the sweet spot is ~2π × 376 kHz, resulting in a repetition time of about 2.5 μs where the time is several times longer than the qubit lifetime T1 = 1/Γ1 ≈ 420 ns.
Our single-photon source is frequency-tunable over a wide frequency range. The operation frequency is adjusted by changing the qubit frequency with the external magnetic flux and adjusting the frequency of the microwave source that generates the π-pulse and the cancellation pulse. Here we show tunability of up to 600 MHz, where it is limited by flux noise producing large jumps in the qubit frequency when the qubit is tuned too far away from the flux sweet spot (Φ = 0).
Intrinsic quantum efficiency
Different from the overall quantum efficiency, the intrinsic quantum efficiency only depends on the qubit coherence, which is the upper bound for the overall efficiency. We also investigate the intrinsic quantum efficiency which is given by ηq = Γr/(2Γ2), of our single-photon source over the frequency range 4.9–5.5 GHz. The quantum efficiency is in the range 71–99% (red in Fig. 4a), extracted from the reflection coefficient. Typically, the pure dephasing rate Γϕ can decohere the supposition of vacuum and a single-photon Fock state, resulting in a decrease in the single-photon quantum efficiency. Moreover, a single photon can be dissipated into the environment through the non-radiative decay channel due to the qubit interaction with the environment. We denote that the reduction of the quantum efficiency from these two effects as ηp = Γϕ/Γ2 and ηn = Γn/2Γ2, respectively. Here, the values of ηp are based on the exponential decay from the qubit emission as discussed below (black, in Fig. 4a). Then, we calculate ηn indirectly, from ηn = Γn/2Γ2 = 1 − ηp − ηq (blue, in Fig. 4a). we find that the non-radiative decay only affects the quantum efficiency near the maximal qubit frequency. When we tune the qubit frequency down, the pure phasing dominates the reduction of the quantum efficiency. Therefore, it is necessary to understand which type of noise induces the pure dephasing rate.
To extract Γϕ, we send a pulse with the amplitude close to a π/2-pulse, and measure the qubit emission with 3.84 × 107 averages. From the emission decay, we can extract both Γ1 and Γ2, the power decay \(\propto {e}^{-{{{\Gamma }}}_{{{{{{\rm{1}}}}}}}t}\), and the quadrature decay \(\propto {e}^{-{{{\Gamma }}}_{{{{{{\rm{2}}}}}}}t}\). Then, Γϕ can be calculated from Γϕ = Γ2 − Γ1/2. In Fig. 4b, the data (black) shows that the pure dephasing rate increases when the qubit is tuned away from the flux sweet spot further. The averaged pure dephasing rate \(\overline{{{{\Gamma }}}_{\phi }}\) over the whole frequency range is about 2π*10 Hz. The pure dephasing rate Γϕ due to 1/f flux noise with the flux noise spectral density SΦ(f) = AΦ/f has the relationship \({{{\Gamma }}}_{\phi }=\sqrt{{A}_{{{\Phi }}}| {{{{\mathrm{ln}}}}}\,(2\pi {f}_{{{{{{\rm{IR}}}}}}}t)| }\frac{\partial {\omega }_{01}}{\partial {{\Phi }}}\)37. fIR is the infrared cutoff frequency, taken to be 5 mHz determined by the measurement time, and t is on the order of \({\overline{{{{\Gamma }}}_{\phi }}}^{-1}\). Using this relationship to fit the extracted Γϕ values shown as a dashed line in Fig. 4b, we obtain \({A}_{{{\Phi }}}^{1/2}\approx 2\mu {{{\Phi }}}_{0}\), which is consistent with other measurements37,38.
In Fig. 4c, from 5.51 to 5.39 GHz, we find that the non-radiative decay rate Γn decreases gradually from 100 kHz to zero. We suspect that some TLSs with a certain bandwidth are located around the flux sweet spot. Since in this range the pure dephasing rate Γϕ is less than 20 kHz (Fig. 4b) with the increasing rate slower than the reduction rate of Γn, the quantum efficiency of our single-photon source in Fig. 4a grows from 80 to 94%. Especially near the flux sweet spot, the non-radiative decay is several times larger than the pure dephasing rate, leading to the quantum efficiency mainly limited by the non-radiative decay. At the two exceptional data points where we obtain negative values of Γn (Fig. 4c), around 5.2 GHz, the efficiency is up to 99%, indicating that during the reflection coefficient measurement at this frequency, both the pure dephasing rate and non-radiative decay rate are very small. When we tune the qubit frequency further away from the flux sweet spot, the non-radiative decay remains close to zero whereas the pure decay rate is increased to be around 35 kHz, leading to a decreased quantum efficiency around 71%. (See a more detailed analysis in the “Methods” section).
Stability
Recently, many works demonstrated that fluctuating TLSs can limit the coherence of superconducting qubits27,39,40,41. Here, we investigate how the fluctuations affect different properties of our single-photon source. We repeatedly measure Γ1 and Γ2 interleaved at Φ = 0 and Φ = 0.09Φ0, corresponding to ω01,1 = ω01(0) = 2π × 5.51 GHz and ω01,2 = ω01(0.09Φ0) = 2π × 5.39 GHz, respectively. At the same time, the fluctuations of the qubit frequency are also obtained from the phase information of the emitted field which carries information about the qubit operator \(\langle {\sigma }_{-}\rangle \propto {e}^{i\delta {\omega }_{01}t}\) where δω01 is the frequency difference between the frequency of the driving pulse and the qubit frequency. The total measurement spans 4.90 × 105 s (~136 h) with 2000 repetitions for each qubit frequency. Each repetition has 3.20 × 106 averages. From the values of Γ1 and Γ2, we extract Γϕ values shown in Fig. 5a, b from averaging over 8 repetitions. We find that Γ1 remains stable for both zero detuning and 120 MHz detuning in Fig. 6. By assuming that Γr is stable over time, this implies that for this detuning Γn is also stable on the scale of Γr.
However, the fluctuations of the qubit frequency, δf,i = (ω01,i − 〈ω01,i〉)/2π and the pure dephasing rate are obvious as shown in Fig. 5a for δf,1 and (b) for δf,2. First, we note the frequency jumps for the case of 120 MHz detuning (i.e. around ω01,2) at t = 16 h and t = 90 h do not affect the pure dephasing rate. We suspect that this is due to a change in the flux offset through the SQUID, as we tune the qubit back and forth by the applied external flux that could induce a change in magnetic polarization in cold components. Therefore, we can not see significant fluctuations at the flux sweet spot.
Other frequency-switching events happening at t = 95 h and t = 120 h for 0 MHz detuning (i.e. around ω01,1) and those before t = 10 h and at t = 64 h for 120 MHz detuning show a strong positive correlation with the pure dephasing rate. Interestingly, the fluctuations do not happen at the same time for both detunings. Combining this with the fact that Γ1 is stable, we speculate that this is due to two uncorrelated TLSs with a small decay rate γi (i = 1, 2), close to ω01,i, dispersively coupled to the qubit (see more details in the section “Methods”). Thus, these two TLSs can only cause the pure dephasing, but not dominate the relaxation, which can explain the stronger fluctuations in Γϕ compared to Γ1 shown in Fig. 6.
Evidently, these two TLSs reduce the intrinsic quantum efficiency substantially by up to 40% and 60% as shown in Fig. 5c for detunings of 0 and 120 MHz, respectively. The effect from TLSs is stronger than other types of noises, especially in the case of zero detuning. At zero detuning we also note that between these large fluctuations the single-photon source can be stable for tens of hours. However, the qubit becomes more sensitive to the 1/f flux noise when it is detuned by 120 MHz, it results in about a 20% fluctuation of the quantum efficiency over the total measurement time. This indicates that 1/f flux noise will be the dominant noise when we tune the qubit frequency away from the flux sweet spot.
Since our single-photon source has a narrow bandwidth it will be meaningful to investigate the frequency stability over a long time, from Fig. 5a, b, we find that at Φ = 0 the frequency fluctuations due to TLSs can be up to 100 kHz which is nearly one third of the single-photon linewidth (Γr = 270 kHz). However, just tuned down the qubit frequency by 120 MHz (Φ = 0.09), the external flux jumps described above dominate the frequency shift of the single-photon source, the shifts can be up to 200 kHz which is a factor of two compared to the effect from TLSs.
Discussion
In this paper, we demonstrate a method to implement a frequency-tunable single-photon source by using a superconducting qubit. We measure the moments of the emitted field, and from those we can evaluate both the second order correlation function and the Wigner function. Our study illustrates that the intrinsic quantum efficiency of our single-photon source can reach up to 99%, which could be improved further by engineering a large radiative decay rate of the qubit into the waveguide transmission line. Moreover, the photon leakage from the canceled input π-pulse is as low as 0.5% of a photon, indicating that our single-photon source is very pure. The frequency tunable range of our single-photon source corresponds to 1600 × Γ1, reaching state of the art and enabling us to address quantum memories with a large number of different ‘colors.’
We also study the noise mechanisms which limit the intrinsic quantum efficiency in detail. The non-radiative decay rate and the pure dephasing rate from the 1/f flux noise both contribute to the reduced quantum efficiency. The 1/f flux noise could be decreased by reducing the density of surface spins by surface treatment of the sample, e.g. annealing42 and UV illumination43.
Finally, we investigate the stability of our single-photon source, which is important for long time operation. The instability originates mainly from the increased sensitivity to 1/f flux noise when the source frequency is tuned down from the flux-insensitive bias point. The results show that the source can be stable for tens of hours at the maximum frequency. However, sometimes, the quantum efficiency decreases by up to 60% when the qubit couples to TLSs. Besides reducing the quantum efficiency, the TLSs can also change the frequency of the single photons by up to one third of the linewidth. However, the environment flux jump will be the dominant noise to shift the single-photon frequency, which could be further reduced by magnetic shields e.g. Cryoperm shielding27,44.
Methods
Measurement setup and qubit characterization
Figure 7a shows the detailed experimental setup. To characterize the qubit a vector network analyzer (VNA) generates a weak coherent probe with the frequency ωpr. The signal is fed into the input line, attenuated to be weak (Ω < Γ1) and interacts with the qubit. Then, the VNA receives the reflected signal from the output line after the amplification to determine the complex reflection coefficient, r. Two-tone spectroscopy is then done to obtain the qubit anharmonicity. Specifically, we apply a strong pump at ω01 to saturate the \(\left|0\right\rangle -\left|1\right\rangle\) transition. Meanwhile, we combine a weak probe with the strong pump together via a 20 dB directional coupler. The frequency of the weak probe from the VNA is swept near the \(\left|1\right\rangle -\left|2\right\rangle\) transition. When the probe is on resonance, again, we will get a dip in the magnitude response of r, leading to α = (ω01 − ω12)/\(\hslash\) = 2π*0.251 GHz (not shown).
Fano-shape spectroscopy
When we measure the reflection coefficient at different qubit frequencies, we notice that at some frequencies the amplitude of the spectroscopy is not flat but has a Fano shape (Fig. 8a). This Fano shape may affect the extracted Γr values, and we argue that the Fano shape originates from an impedance mismatch in the measurement setup which will result in a modified reflection coefficient as31:
where
r1 (t1) is the reflection (transmission) coefficient at the place where the impedance mismatch is located, and β is proportional to the attenuation between the place and the sample. ϕ0 = ωτ is the extra phase of the propagating wave from the propagating time τ, due to the distance between the qubit and the impedance mismatch. We use Eq. (3) to fit the data to extract the values of Φ at different qubit frequencies which are thus fit to Eq. (4) as show in Fig. 9a. The extracted r1 ≈ 0.14 close to 0.1 (corresponding −20 dB in power) and β ≈ 0.97 corresponding to 0.26 dB attenuation indicate that the impedance mismatch probably arises from the directional coupler.
Afterwards, to compensate the impedance mismatch, we calculate rcomp = 1 − (1 − rraw) * eiϕ where rraw is the raw data (blue in Fig. 8a, b). The magnitude response of rcomp in Fig. 8c manifests that the impedance mismatch has been corrected. We repeat this process for other qubit frequencies and then fit the calculated data to obtain Γr and Γ2 (red stars in Fig. 9b, c). Comparing to the values before correcting the impedance mismatch (blue dots in Fig. 9b, c), we find they are close to each other.
Two-level fluctuator model
Figure 6 shows the fluctuations of Γ1 and Γ2 at ω01,1/(2π) = 5.51 GHz and ω01,2/(2π)5.39 GHz over 136 h. We denote gi and Δi = (ωTLS,i − ω01,i)/(2π) as the coupling strength and the frequency detuning between the TLS and the qubit, respectively. In addition, Γn,i and Γ1,i are the corresponding non-radiative decay rate and relaxation at each qubit frequency. To simplify the model, we let g1 = g2. When gi ≪ Δi ≪ 120 MHz, we have a dispersive shift \({\chi }_{{{{{{\rm{i}}}}}}}={g}_{{{{{{\rm{i}}}}}}}^{2}/{{{\Delta }}}_{{{{{{\rm{i}}}}}}}\). Typically, the surface TLS coupling rates are on the order of g ≈ 100 kHz40. Since the measured frequency shifts of both qubit frequencies are almost the same, about 40 kHz, the detuning to such a TLS is ~\({{{\Delta }}}_{{{{{{\rm{i}}}}}}}={g}_{{{{{{\rm{i}}}}}}}^{2}/{\chi }_{{{{{{\rm{i}}}}}}}=2.5\,{{{{{\rm{MHz}}}}}}\), which is about 9 × Γ1,i. From the shortest duration of the TLS fluctuations in Fig. 5b, we can estimate the switching time of these two TLSs roughly to be 2.88 × 104 s and 7.82 × 103 s, corresponding to γ1 = 34.7 μHz and γ2 = 127.9 μHz, respectively. According to \({{{\Gamma }}}_{{{{{{\rm{n}}}}}},{{{{{\rm{i}}}}}}}\propto {g}_{{{{{{\rm{i}}}}}}}^{2}/{{{\Delta }}}_{{{{{{\rm{i}}}}}}}^{2}{\gamma }_{{{{{{\rm{i}}}}}}}=0.16 \% {\gamma }_{{{{{{\rm{i}}}}}}}\). Thus, these two TLSs can only cause the pure dephasing, but not dominate the relaxation. This can also explain the stronger fluctuations in Γϕ compared to Γ1 shown in Fig. 6. We emphasize that the fresh finding here is that we notice TLSs can be activated independently where there is only a single TLS was investigated in ref. 40.
Directional coupler parameters
Directional coupler parameters are shown in Table 2. The approximate values of the commercial directional coupler used in our setup as measured by a VNA. Even though these values are measured at room temperature, they should be close to the values at 10 mK. The attenuation between the input and ain is about −21.7 dB including the insertion loss, very close to −20 dB which is the value printed on the coupler.
Measurement consistency
In order to obtain the non-radiative decay rate and the quantum-efficiency reduction from that, we need to combine results from different measurements as we discussed in Fig. 4. We obtain Γn = Γ1 − Γr where Γ1 can be either measured from the exponential decay of the qubit emission or the power spectrum, and Γr is based on the reflection coefficient. Therefore, it is necessary to check whether the qubit is stable over these measurements. In Fig. 10, we show the extracted values of Γ2 from different methods, over the frequency range of 4.91–5.51 GHz. We find that the values of Γ2 from different methods agree well except for the data points at 5.2 and 5.3 GHz. This inconsistency is probably due to the redistribution of TLSs27,39 between different measurements, since there are a few-days delay when we take these different measurements. Because of this inconsistency, we have slightly negative values of Γn and ηn as shown in Fig. 4a, c, respectively.
Data availability
The data that supports the findings of this study is available from the corresponding authors upon reasonable request.
Code availability
The code that supports the findings of this study is available from the corresponding authors upon reasonable request
References
Degen, C. L., Reinhard, F. & Cappellaro, P. Quantum sensing. Rev. Mod. Phys. 89, 035002 (2017).
Kimble, H. J. The quantum internet. Nature 453, 1023 (2008).
Knill, E., Laflamme, R. & Milburn, G. J. A scheme for efficient quantum computation with linear optics. Nature 409, 46 (2001).
Kok, P. et al. Linear optical quantum computing with photonic qubits. Rev. Mod. Phys. 79, 135 (2007).
Zhong, H.-S. et al. Quantum computational advantage using photons. Science 370, 1460 (2020).
Somaschi, N. et al. Near-optimal single-photon sources in the solid state. Nat. Photonics 10, 340 (2016).
Senellart, P., Solomon, G. & White, A. High-performance semiconductor quantum-dot single-photon sources. Nat. Nanotechnol. 12, 1026 (2017).
Schweickert, L. et al. On-demand generation of background-free single photons from a solid-state source. Appl. Phys. Lett. 112, 093106 (2018).
Barends, R. et al. Quasiparticle relaxation in optically excited high-q superconducting resonators. Phys. Rev. Lett. 100, 257002 (2008).
Reagor, M. et al. Reaching 10 ms single photon lifetimes for superconducting aluminum cavities. Appl. Phys. Lett. 102, 192604 (2013).
MacCabe, G. S. et al. Nano-acoustic resonator with ultralong phonon lifetime. Science 370, 840 (2020).
Chu, Y. et al. Creation and control of multi-phonon fock states in a bulk acoustic-wave resonator. Nature 563, 666 (2018).
Houck, A. A. et al. Generating single microwave photons in a circuit. Nature 449, 328 (2007).
Lang, C. et al. Correlations, indistinguishability and entanglement in Hong-Ou-Mandel experiments at microwave frequencies. Nat. Phys. 9, 345 (2013).
Pechal, M. et al. Microwave-controlled generation of shaped single photons in circuit quantum electrodynamics. Phys. Rev. X 4, 041010 (2014).
Leppäkangas, J. et al. Antibunched photons from inelastic cooper-pair tunneling. Phys. Rev. Lett. 115, 027004 (2015).
Grimm, A. et al. Bright on-demand source of antibunched microwave photons based on inelastic cooper pair tunneling. Phys. Rev. X 9, 021016 (2019).
Rolland, C. et al. Antibunched photons emitted by a dc-biased Josephson junction. Phys. Rev. Lett. 122, 186804 (2019).
Lindkvist, J. & Johansson, G. Scattering of coherent pulses on a two-level system-single-photon generation. N. J. Phys. 16, 055018 (2014).
Peng, Z., De Graaf, S., Tsai, J. & Astafiev, O. Tuneable on-demand single-photon source in the microwave range. Nat. Commun. 7, 12588 (2016).
Pechal, M. et al. Superconducting switch for fast on-chip routing of quantum microwave fields. Phys. Rev. Appl. 6, 024009 (2016).
Zhou, Y., Peng, Z., Horiuchi, Y., Astafiev, O. & Tsai, J. Tunable microwave single-photon source based on transmon qubit with high efficiency. Phys. Rev. Appl. 13, 034007 (2020).
Sathyamoorthy, S. R. et al. Simple, robust, and on-demand generation of single and correlated photons. Phys. Rev. A 93, 063823 (2016).
Forn-Diaz, P., Warren, C. W., Chang, C. W. S., Vadiraj, A. M. & Wilson, C. M. On-demand microwave generator of shaped single photons. Phys. Rev. Appl. 8, 54015 (2017).
Hoi, I.-C. et al. Probing the quantum vacuum with an artificial atom in front of a mirror. Nat. Phys. 11, 1045 (2015).
Lin, W.-J. et al. Deterministic loading and phase shaping of microwaves onto a single artificial atom. arXiv:2012.15084 (2020).
Burnett, J. J. et al. Decoherence benchmarking of superconducting qubits. npj Quantum Inform. 5, 54 (2019).
Koshino, K. & Nakamura, Y. Control of the radiative level shift and linewidth of a superconducting artificial atom through a variable boundary condition. N. J. Phys. 14, 043005 (2012).
Macklin, C. et al. A near–quantum-limited Josephson traveling-wave parametric amplifier. Science 350, 307 (2015).
Lu, Y. et al. Characterizing decoherence rates of a superconducting qubit by direct microwave scattering. npj Quantum Inform. 7, 35 (2021).
Lu, Y. et al. Propagating Wigner-negative states generated from the steady-state emission of a superconducting qubit. Phys. Rev. Lett. 126, 253602 (2021).
Astafiev, O. et al. Resonance fluorescence of a single artificial atom. Science 327, 840 (2010).
Cahill, K. E. & Glauber, R. J. Density operators and quasiprobability distributions. Phys. Rev. 177, 1882 (1969).
Eichler, C., Bozyigit, D. & Wallraff, A. Characterizing quantum microwave radiation and its entanglement with superconducting qubits using linear detectors. Phys. Rev. A 86, 032106 (2012).
Johansson, J. R., Nation, P. D. & Nori, F. Qutip: An open-source python framework for the dynamics of open quantum systems. Comput. Phys. Commun. 183, 1760 (2012).
James, D. F., Kwiat, P. G., Munro, W. J. & White, A. G. Measurement of qubits. Phys. Rev. A 64, 052312 (2001).
Hutchings, M. et al. Tunable superconducting qubits with flux-independent coherence. Phys. Rev. Appl. 8, 044003 (2017).
Bialczak, R. C. et al. 1/f flux noise in Josephson phase qubits. Phys. Rev. Lett. 99, 187006 (2007).
Klimov, P. et al. Fluctuations of energy-relaxation times in superconducting qubits. Phys. Rev. Lett. 121, 090502 (2018).
Schlör, S. et al. Correlating decoherence in transmon qubits: low frequency noise by single fluctuators. Phys. Rev. Lett. 123, 190502 (2019).
Lisenfeld, J. et al. Electric field spectroscopy of material defects in transmon qubits. npj Quantum Inf. 5, 105 (2019).
De Graaf, S. et al. Suppression of low-frequency charge noise in superconducting resonators by surface spin desorption. Nat. Commun. 9, 1143 (2018).
Kumar, P. et al. Origin and reduction of 1/f magnetic flux noise in superconducting devices. Phys. Rev. Appl. 6, 041001 (2016).
Kreikebaum, J. M., Dove, A., Livingston, W., Kim, E. & Siddiqi, I. Optimization of infrared and magnetic shielding of superconducting tin and al coplanar microwave resonators. Supercond. Sci. Technol. 29, 104002 (2016).
Acknowledgements
The authors acknowledge the use of the Nano fabrication Laboratory (NFL) at Chalmers. We also acknowledge IARPA and Lincoln Labs for providing the TWPA used in this experiment. We wish to express our gratitude to Lars Jönsson for help and we appreciate the fruitful discussions with Prof. Simone Gasparinetti, Dr. Marek Pechal, Dr. Neill Lambert and Ingrid Strandberg. This work was supported by the Knut and Alice Wallenberg Foundation via the Wallenberg Center for Quantum Technology (WACQT) and by the Swedish Research Council. B.S. acknowledges the support of the DST-SERB-CRG and Infosys Young Investigator grants.
Funding
Open access funding provided by Chalmers University of Technology.
Author information
Authors and Affiliations
Contributions
P.D. and Y.L. planned the project. Y.L. performed the measurements with the input from A.B., J.J.B, B.S., and P.D. Y.L. designed and A.B. fabricated the sample. Y.L. developed the theoretical expressions. H.R.N. and Y.L. set up the TWPA. Y.L. wrote the manuscript with input from all the authors. Y.L. analyzed the data with inputs from J.B. and P.D. P.D. supervised this work.
Corresponding authors
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Lu, Y., Bengtsson, A., Burnett, J.J. et al. Quantum efficiency, purity and stability of a tunable, narrowband microwave single-photon source. npj Quantum Inf 7, 140 (2021). https://doi.org/10.1038/s41534-021-00480-5
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41534-021-00480-5
- Springer Nature Limited
This article is cited by
-
Towards a microwave single-photon counter for searching axions
npj Quantum Information (2022)