Abstract
Purpose
d-Dimer estimation has been proposed as a reliable biomarker in prosthetic joint infections. Its role in non-prosthetic orthopaedic implant infections has, however, not been studied. The objectives of this study were to assess the levels of plasma d-Dimer in non-prosthetic orthopaedic implant infection. The diagnostic efficiency of d-dimer on orthopaedic implant-related infection was evaluated.
Methods
The study was designed as a cross-sectional comparative study. Patients who presented with orthopaedic implant-related infection as diagnosed by modified MSIS criteria were allocated to case group (n = 49) and patients who underwent surgical procedures with orthopaedic implants with no evidence of infection at 6 weeks postoperatively were allocated to the control group (n = 48). Serum d-Dimer levels were assessed quantitatively using immunoturbidimetric assays in both groups and compared between both groups.
Results
The mean (± SD) value of serum d-Dimer in case group was 0.64 (± 0.45) μg/ml and control group was 0.77 (± 0.47) μg/ml. No significant difference was found in serum d-Dimer levels between cases and control groups (p value = 0.183). The diagnostic accuracy of d-dimer in orthopaedic implant-related infection also could not be demonstrated.
Conclusion
The findings of d-dimer as a marker for the diagnosis of prosthetic joint infections cannot be extrapolated to non-prosthetic orthopaedic implant infection.
Similar content being viewed by others
References
Gabay, C., & Kushner, I. (1999). Acute-phase proteins and other systemic responses to inflammation. New England Journal of Medicine, 340, 448.
Antoniak, S. (2018). The coagulation system in host defense. Research and Practice in Thrombosis and Haemostasis, 2(3), 549–557.
Weitz, J. I., Fredenburgh, J. C., & Eikelboom, J. W. (2017). A test in context: d-dimer. Journal of the American College of Cardiology, 70(19), 2411–2420.
Shahi, A., Kheir, M. M., Tarabichi, M., Hosseinzadeh, H. R. S., Tan, T. L., & Parvizi, J. (2017). Serum d-dimer test is promising for the diagnosis of periprosthetic joint infection and timing of reimplantation. The Journal of Bone and Joint Surgery, 99(17), 1419–1427.
Goebel, P. J., Williams, J. B., & Gerhardt, R. T. (2010). A pilot study of the performance characteristics of the d-dimer in presumed sepsis. The Western Journal of Emergency Medicine, 2, 7.
Hao, L., & Wang, N. (2013). Changes in plasma thrombomodulin and d-dimer levels and their clinical significance in neonates with sepsis. Chinese Journal of Contemporary Pediatrics, 15(10), 841–844.
Kaya, B., Sana, B., Eris, C., Karabulut, K., Bat, O., & Kutanis, R. (2012). The diagnostic value of d-dimer, procalcitonin and CRP in acute appendicitis. International Journal of Medical Sciences, 9(10), 909–915.
Lee, Y. S., Lee, Y. K., Han, S. B., Nam, C. H., Parvizi, J., & Koo, K. H. (2018). Natural progress of D-dimer following total joint arthroplasty: A baseline for the diagnosis of the early postoperative infection. Journal of Orthopaedic Surgery and Research, 13, 36.
Alijanipour, P., Bakhshi, H., & Parvizi, J. (2013). Diagnosis of periprosthetic joint infection: The threshold for serological markers. Clinical Orthopaedics and Related Research, 471(10), 3186–3195.
Wang, Z., Zheng, C., Wen, S., Wang, J., Zhang, Z., Qiu, X., et al. (2019). Usefulness of serum d-dimer for preoperative diagnosis of infected nonunion after open reduction and internal fixation. Infection and Drug Resistance, 1(12), 1827–1831.
Alvand, A., Rezapoor, M., & Parvizi, J. (2017). The role of biomarkers for the diagnosis of implant-related infections in orthopaedics and trauma. Advances in Experimental Medicine and Biology, 971, 69–79.
Morgenstern, M., Kühl, R., Eckardt, H., Acklin, Y., Stanic, B., Garcia, M., et al. (2018). Diagnostic challenges and future perspectives in fracture-related infection. Injury, 49, S83–90.
Metsemakers, W. J., Morgenstern, M., McNally, M. A., Moriarty, T. F., McFadyen, I., Scarborough, M., et al. (2018). Fracture-related infection: A consensus on definition from an international expert group. Injury, 49(3), 505–510.
Tschudin-Sutter, S., Frei, R., Dangel, M., Jakob, M., Balmelli, C., Schaefer, D. J., et al. (2016). Validation of a treatment algorithm for orthopaedic implant-related infections with device-retention—results from a prospective observational cohort study. Clinical Microbiology and Infection, 22(5), 457.e1–457.e9.
Bytniewski, P., Macha, W., Romanowski, L., Wiśniewski, W., & Kosowski, K. (2014). The dynamics of d-dimer level fluctuation in patients after the cemented and cementless total hip and total knee replacement. Journal of Orthopaedic Surgery and Research, 9, 89.
Zhang, J., & Li, M. (2017). A call for standardization and age adjusted d-dimer cut-off value. Journal of Blood Disorders Symptoms and Treatments, 1, 2.
Rodelo, J. R., De la Rosa, G., Valencia, M. L., Ospina, S., Arango, C. M., Gómez, C. I., et al. (2012). d-dimer is a significant prognostic factor in patients with suspected infection and sepsis. American Journal of Emergency Medicine, 30(9), 1991–1999.
Xiong, L., Li, S., & Dai, M. (2019). Comparison of d-dimer with CRP and ESR for diagnosis of periprosthetic joint infection. Journal of Orthopaedics Surgery and Research, 14, 240.
Li, R., Shao, H.-Y., Hao, L.-B., Yu, B.-Z., Qu, P.-F., Zhou, Y.-X., et al. (2019). Plasma fibrinogen exhibits better performance than plasma d-dimer in the diagnosis of periprosthetic joint infection: A multicenter retrospective study. Journal of Bone and Joint Surgery, 101(7), 613–619.
Xu, H., Xie, J., Huang, Q., Lei, Y., Zhang, S., & Pei, F. (2019). Plasma fibrin degradation product and D-dimer are of limited value for diagnosing periprosthetic joint infection. Journal of Arthroplasty, 34(10), 2454–2460.
Funding
This study was funded by an intra-mural grant from the Jawaharlal Institute of Postgraduate Medical Education and Research, Pondicherry, India.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of Interest
The authors declare that they have no conflict of interest.
Ethics Approval
The study was done in accordance with the ethical standards of the institutional research committee (Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India, Project number: JIP/IEC/2017/0256) and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
Consent to Participate
Informed consent was obtained from all individual participants included in the study.
Consent to Publish
Patients signed informed consent regarding publishing their data and photographs.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
About this article
Cite this article
Karunakaran, G., Menon, J., Nema, S. et al. Plasma d-Dimer Levels in Non-prosthetic Orthopaedic Implant Infection: Can it Aid Diagnosis?. JOIO 54 (Suppl 1), 76–80 (2020). https://doi.org/10.1007/s43465-020-00120-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s43465-020-00120-8