Abstract
Purpose
Breast cancer is one of the most diffuse diseases and its incidence rate is increasing. Mammography is the gold standard exam for screening breast cancer. Nevertheless, to provide better conditions for visualization and detection of tumors, in particular to young women, techniques exploiting the X-ray phase contrast to generate images have been studied and proposed for clinical use. As every imaging modality clinically implemented, the capabilities and limitations of an X-ray phase-contrast system dedicated to breast imaging should be evaluated by a phantom. Although for mammography, there are several commercial phantoms, for tomographic X-ray phase-contrast imaging systems dedicated to breast screening, they are absent. Therefore, this study aimed to design a breast phantom for application in phase-contrast computed tomography (PC-CT) imaging.
Methods
A breast phantom dedicated to X-ray phase-contrast imaging was designed. The phantom has a cylindrical shape and is composed by PMMA, to mimic the breast of a young woman, with some inserts filled with tissue substitutes to normal and pathological breast tissues, such as ethanol and glycerol. These materials were chosen due to the similarity in the attenuation and scattering properties of normal and pathological human breast tissues.
Results
A comparison between tomographic X-ray absorption imaging and tomographic X-ray phase-contrast imaging showed a significant increase in edges definition, even with materials with similar attenuation properties.
Conclusion
The results of this work reinforce the need for dedicated phantoms to exploit the features of each imaging modality more realistic. In particular, the breast phantom–designed breast screening by PC-CT allows exploiting the features of this new imaging modality.
Similar content being viewed by others
References
Al-Bahri JS, Spyrou NM. Electron density of normal and pathological breast tissues using a Compton scattering technique. Appl Radiat Isot. 1998;49:1677–84. https://doi.org/10.1016/S0969-8043(97)10106-3.
Antoniassi M, Conceiçao ALC, Poletti ME. Characterization of breast tissues using Compton scattering. Nucl Instruments Methods Phys Res Sect A Accel Spectrometers, Detect Assoc Equip. 2010;619:375–8. https://doi.org/10.1016/j.nima.2010.01.027.
Antoniassi M, Conceição ALC, Poletti ME. Study of effective atomic number of breast tissues determined using the elastic to inelastic scattering ratio. Nucl Instruments Methods Phys Res Sect A Accel Spectrometers, Detect Assoc Equip. 2011;652:739–43. https://doi.org/10.1016/j.nima.2010.09.110.
Berg WA, Blume JD, Cormack JB, Mendelson EB, Lehrer D, Böhm-Vélez M, et al. Investigators for the A 6666. Combined screening with ultrasound and mammography vs mammography alone in women at elevated risk of breast cancer. JAMA. 2008;299:2151–63. https://doi.org/10.1001/jama.299.18.2151.
Berg WA, Zhang Z, Lehrer D, Jong RA, Pisano ED, Barr RG, et al. Investigators for the A 6666. Detection of breast cancer with addition of annual screening ultrasound or a single screening MRI to mammography in women with elevated breast cancer risk. JAMA. 2012;307:1394. https://doi.org/10.1001/jama.2012.388.
Bravin A, Keyriläinen J, Fernández M, Fiedler S, Nemoz C, Karjalainen-Lindsberg M-L, et al. High-resolution CT by diffraction-enhanced x-ray imaging: mapping of breast tissue samples and comparison with their histo-pathology. Phys Med Biol. 2007;52:2197–211. https://doi.org/10.1088/0031-9155/52/8/011.
Bravin A, Coan P, Suortti P. X-ray phase-contrast imaging: from pre-clinical applications towards clinics. Phys Med Biol. 2013;58:R1–35. https://doi.org/10.1088/0031-9155/58/1/R1.
Byng JW, Mainprize JG, Yaffe MJ. X-ray characterization of breast phantom materials. Phys Med Biol. 1998;43:1367–77. https://doi.org/10.1088/0031-9155/43/5/026.
Caldwell C, Yaffe M. Development of an anthropomorphic breast phantom. Med Phys. 1990;17:273–80.
Carton A-K, Bakic P, Ullberg C, Derand H, Maidment ADA. Development of a physical 3D anthropomorphic breast phantom. Med Phys. 2011;38:891–6. https://doi.org/10.1118/1.3533896.
Castelli E, Tonutti M, Arfelli F, Longo R, Quaia E, Rigon L, et al. Mammography with synchrotron radiation: first clinical experience with phase-detection technique. Radiology. 2011;259:684–94. https://doi.org/10.1148/radiol.11100745.
Chelli R, Procacci P, Cardini G, Della Valle RG, Califano S. Glycerol condensed phases. Part I. A molecular dynamics study. Phys Chem Chem Phys. 1999;1:871–7. https://doi.org/10.1039/a808958b.
Coan P, Bravin A, Tromba G. Phase-contrast x-ray imaging of the breast: recent developments towards clinics. J Phys D Appl Phys. 2013;46:494007. https://doi.org/10.1088/0022-3727/46/49/494007.
Conceição ALC, Antoniassi M, Cunha DM, Ribeiro-Silva A, Poletti ME. Multivariate analysis of the scattering profiles of healthy and pathological human breast tissues. Nucl Instruments Methods Phys Res Sect A Accel Spectrometers, Detect Assoc Equip. 2011;652:870–3. https://doi.org/10.1016/j.nima.2010.08.060.
Conceição ALC, Antoniassi M, Geraldelli W, Poletti ME. Mapping transitions between healthy and pathological lesions in human breast tissues by diffraction enhanced imaging computed tomography (DEI-CT) and small angle x-ray scattering (SAXS). Radiat Phys Chem. 2014;95:313–6. https://doi.org/10.1016/j.radphyschem.2013.02.025.
Cunha DM, Oliveira OR, Pérez CA, Poletti ME. X-ray scattering profiles of some normal and malignant human breast tissues. X-Ray Spectrom. 2006;35, John Wiley & Sons, Ltd.:370–4. https://doi.org/10.1002/xrs.921.
Donath T, Pfeiffer F, Bunk O, Grünzweig C, Hempel E, Popescu S, Vock P, David C (2010) Toward clinical X-ray phase-contrast CT. Investig Radiol 1. doi: https://doi.org/10.1097/RLI.0b013e3181e21866.
Fernández M, Keyriläinen J, Serimaa R, Torkkeli M, Karjalainen-Lindsberg M-L, Leidenius M, et al. Human breast cancer in vitro : matching histo-pathology with small-angle x-ray scattering and diffraction enhanced x-ray imaging. Phys Med Biol. 2005;50:2991–3006. https://doi.org/10.1088/0031-9155/50/13/002.
Fiedler S, Bravin A, Keyriläinen J, Fernández M, Suortti P, Thomlinson W, et al. Imaging lobular breast carcinoma: comparison of synchrotron radiation DEI-CT technique with clinical CT, mammography and histology. Phys Med Biol. 2004;49:175–88. https://doi.org/10.1088/0031-9155/49/2/001.
Hartman A-R, Daniel BL, Kurian AW, Mills MA, Nowels KW, Dirbas FM, et al. Breast magnetic resonance image screening and ductal lavage in women at high genetic risk for breast carcinoma. Cancer. 2004;100:479–89. https://doi.org/10.1002/cncr.11926.
Ikejimba LC, Graff CG, Rosenthal S, Badal A, Ghammraoui B, Lo JY, et al. A novel physical anthropomorphic breast phantom for 2D and 3D x-ray imaging. Med Phys. 2017;44:407–16. https://doi.org/10.1002/mp.12062.
Keyriläinen J, Bravin A, Fernández M, Tenhunen M, Virkkunen P, Suortti P. Phase-contrast X-ray imaging of breast. Acta Radiol. 2010;51:866–84. https://doi.org/10.3109/02841851.2010.504742.
Lewis RA. Medical phase contrast x-ray imaging: current status and future prospects. Phys Med Biol. 2004;49:3573–83. https://doi.org/10.1088/0031-9155/49/16/005.
Mautner B, Schmidt K, Brennan M. New diagnostic techniques and treatments for early breast cancer. Semin Oncol Nurs. 2000;16:185–96.
Morrow M, Waters J, Morris E. MRI for breast cancer screening, diagnosis, and treatment. Lancet. 2011;378:1804–11. https://doi.org/10.1016/S0140-6736(11)61350-0.
National Institute of Standards and Technology - Physical Measuring Laboratory (2018) [cited 2017 July 27]. Available from: https://physics.nist.gov/PhysRefData/Xcom/html/xcom1.html
Niklason LT, Christian BT, Niklason LE, Kopans DB, Castleberry DE, Opsahl-Ong BH, et al. Digital tomosynthesis in breast imaging. Radiology. 1997;205:399–406. https://doi.org/10.1148/radiology.205.2.9356620.
NIST (1999) NIST XCOM: Element/Compound/Mixture. Natl Inst Stand Technol. [cited 2017 August 7]. Available from: https://physics.nist.gov/PhysRefData/Xcom/html/xcom1.html
Pagot E, Fiedler S, Cloetens P, Bravin A, Coan P, Fezzaa K, et al. Quantitative comparison between two phase contrast techniques: diffraction enhanced imaging and phase propagation imaging. Phys Med Biol. 2005;50:709–24. https://doi.org/10.1088/0031-9155/50/4/010.
Poletti ME, Gonçalves OD, Mazzaro I. X-ray scattering from human breast tissues and breast-equivalent materials. Phys Med Biol. 2002;47:47–63. https://doi.org/10.1088/0031-9155/47/1/304.
Ribeiro S, Paschuk S, Swinka-Filho V, Schelin H. Analysis of dielectric breakdown in power cables using 2D and 3D tomography. Insight Non-Destructive Test Cond Monit. 2011;53:557–61. https://doi.org/10.1784/insi.2011.53.10.557.
Shakeshaft J, Morgan HM, Lillicrap SC. Gamma-ray scattering for fat fraction measurement. Phys Med Biol. 1997;42:1403–13. https://doi.org/10.1088/0031-9155/42/7/013.
Stampanoni M, Wang Z, Thüring T, David C, Roessl E, Trippel M, et al. The first analysis and clinical evaluation of native breast tissue using differential phase-contrast mammography. Investig Radiol. 2011;46:801–6. https://doi.org/10.1097/RLI.0b013e31822a585f.
Tomal A, Mazarro I, Kakuno EM, Poletti ME. Experimental determination of linear attenuation coefficient of normal, benign and malignant breast tissues. Radiat Meas. 2010;45:1055–9. https://doi.org/10.1016/J.RADMEAS.2010.08.008.
Tomal A, Cunha DM, Poletti ME. Comparison of beam quality parameters computed from mammographic x-ray spectra measured with different high-resolution semiconductor detectors. Radiat Phys Chem. 2014;95:217–20. https://doi.org/10.1016/j.radphyschem.2013.01.002.
Woodard HQ, White DR. The composition of body tissues. Br J Radiol. 1986;59:1209–18. https://doi.org/10.1259/0007-1285-59-708-1209.
Funding
This study was financed in part by the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - Brasil (CAPES) - Finance Code 001. In addition, the authors would like to acknowledge the support of the Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) and of the LACTEC Institute.
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Badelli, J.d., Ribeiro-Junior, S., Antoniassi, M. et al. Breast phantom design for X-ray phase-contrast imaging. Res. Biomed. Eng. 35, 21–26 (2019). https://doi.org/10.1007/s42600-019-00004-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s42600-019-00004-3