A real-time Bonner sphere spectrometer (BSS) has been developed for spectral neutron measurements with the HL-2A Tokamak. To correct and verify the accuracy of the neutron spectrum from the BSS, the BSS system was calibrated using monoenergetic neutron beams in the energy range of 100 keV–5 MeV. The response function of the BSS was corrected based on the calibration results, and the corrected BSS system was verified by unfolding monoenergetic neutron spectra. Fusion neutron spectra on the HL-2A have been obtained from the calibrated BSS system for the first time.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9

Similar content being viewed by others

References

  1. H.W. Kugel, G. Ascione, J. Gilbert, Review of diagnostic methods for TFTR D–T radiation shielding and neutronics studies. Rev. Sci. Instrum. 68, 557 (1997). https://doi.org/10.1063/1.1147652

    Article  Google Scholar 

  2. M.T. Swinhoe, O.N. Jarvis, Measurement and calculation of the efficiency of fission detectors designed to monitor the time dependence of the neutron production of JET. Rev. Sci. Instrum. 56, 1093 (1985). https://doi.org/10.1063/1.1138233

    Article  Google Scholar 

  3. M. Hoek, T. Nishitani, Y. Ikeda et al., Neutron yield measurements by use of foil activation at JT-60U. Rev. Sci. Instrum. 66, 885 (1995). https://doi.org/10.1063/1.1146527

    Article  Google Scholar 

  4. H. Kim, H. Lee, S. Hong et al., Radioactivity evaluation for the KSTAR Tokamak. Radiat. Prot. Dos. 116, 24 (2005). https://doi.org/10.1093/rpd/nci242

    Article  Google Scholar 

  5. D. Liu, C. Zhou, Z. Cao et al., Construction of the HL-2A Tokamak. Fusion Eng. Des. 66–68, 147 (2003). https://doi.org/10.1016/S0920-3796(03)00165-0

    Article  Google Scholar 

  6. Q. Li, Brief introduction to engineering and experiment of HL-2A Tokamak. At. Energy Sci. Technol. 43, 204 (2009). (in Chinese)

    Google Scholar 

  7. Y. Liu, X. Ding, Q. Yang et al., Recent advances in the HL-2A Tokamak experiments. Nucl. Fusion 45, S239–S244 (2005). https://doi.org/10.1088/0029-5515/45/10/S19

    Article  Google Scholar 

  8. I. Klimek, M. Cecconello, M. Gorelenkova et al., TRANSP modelling of total and local neutron emission on MAST. Nucl. Fusion. 55, 023003 (2015). https://doi.org/10.1088/0029-5515/55/2/023003

    Article  Google Scholar 

  9. R.L. Bramblett, R.I. Ewing, T.W. Bonner, A new type of neutron spectrometer. Nucl. Instrum. Methods. 9, 1 (1960). https://doi.org/10.1016/0029-554X(60)90043-4

    Article  Google Scholar 

  10. D.J. Thomas, A.V. Alevra, Bonner sphere spectrometers: a critical review. Nucl. Instrum. Methods A. 476, 12–20 (2002). https://doi.org/10.1016/S0168-9002(01)01379-1

    Article  Google Scholar 

  11. J. Cao, C. Jiang, H. Cao et al., Experimental validation of a Tokamak neutron spectrometer based on Bonner spheres. Chin. Phys. C. 39(8), 086001 (2015). https://doi.org/10.1088/1674-1137/39/8/086001

    Article  Google Scholar 

  12. C. Jiang, J. Cao, X. Jiang et al., Real-time bonner sphere spectrometry on the HL-2A Tokamak. Plasma Sci. Technol. 18, 699 (2016). https://doi.org/10.1088/1009-0630/18/6/19

    Article  Google Scholar 

  13. J. Cao, X. Jiang, C. Jiang et al., Calculation of response function for bonner sphere spectrometer based on Geant4. Plasma Sci. Technol 17, 80 (2015). https://doi.org/10.1088/1009-0630/17/1/15

    Article  Google Scholar 

  14. S. Agostinelli, J. Allison, K. Amako et al., Geant4: a simulation toolkit. Nucl. Instrum. Methods A. 506, 250–303 (2003). https://doi.org/10.1016/S0168-9002(03)01368-8

    Article  Google Scholar 

  15. R. Bedogni, A. Pola, M. Costa et al., A Bonner sphere spectrometer based on a large 6LiI(Eu) scintillator: calibration in reference monoenergetic fields. Nucl. Instrum. Methods A. 897, 18–21 (2018). https://doi.org/10.1016/j.nima.2018.04.040

    Article  Google Scholar 

  16. R.M. Howell, E.A. Burgett, B. Wiegel et al., Calibration of a Bonner sphere extension (BSE) for high-energy neutron spectrometry. Radiat. Meas. 45(10), 1233–1237 (2010). https://doi.org/10.1016/j.radmeas.2010.09.003

    Article  Google Scholar 

  17. B. Wiegel, A.V. Alevra, NEMUS: the PTB neutron multisphere spectrometer—Bonner spheres and more. Nucl. Instrum. Methods A. 476, 36–41 (2002). https://doi.org/10.1016/S0168-9002(01)01385-7

    Article  Google Scholar 

  18. H. Sun, X. Luo, C. Li et al., The measurement of neutron flux using 197Au neutron activation from static accelerator. Nucl. Electron. Detect. Technol. 30, 288–295 (2010). https://doi.org/10.3969/j.issn.0258-0934.2010.02.032. (In Chinese)

    Article  Google Scholar 

  19. Z. Zhu, Y. Hua, W. Chen et al., Efficiency calibration of long counter and its application. J. Sichuan Univ. (Natural Science Edition) 52, 1303 (2015). https://doi.org/10.3969/j.issn.0490-6756.2015.11.021. (in Chinese)

    Article  Google Scholar 

  20. C. Birattari, E. Dimovasili, A. Mitaroff et al., A Bonner sphere spectrometer with extended response matrix. Nucl. Instrum. Methods A. 620, 260–269 (2010). https://doi.org/10.1016/j.nima.2010.04.033

    Article  Google Scholar 

  21. T. Peng, X. Luo, C. Zhang et al., Study on calibration of neutron efficiency and relative photo-yield of plastic scintillator. Nucl. Phys. Rev. 19(3), 57–60 (2002). https://doi.org/10.11804/NuclPhysRev.19.03.357. (in Chinese)

    Article  Google Scholar 

  22. V. Lacoste, V. Gressier, J.L. Pochat et al., Characterization of Bonner sphere system at monoenergetic and thermal neutron fields. Radiat. Prot. Dosim. 110(1–4), 529–532 (2004). https://doi.org/10.1093/rpd/nch279

    Article  Google Scholar 

  23. T. Ogata, S. Kudo, Y. Watanabe et al., The calibration of Bonner sphere spectrometer. Radiat. Prot. Dosim. 146(1–3), 107–110 (2011). https://doi.org/10.1093/rpd/ncr123

    Article  Google Scholar 

  24. A. Cheminet, V. Lacoste, V. Gressier et al., Characterization of the IRSN neutron multisphere spectrometer (HERMEIS) at European standard calibration fields. J. Instrum. 7, C04007 (2012). https://doi.org/10.1088/1748-0221/7/04/C04007

    Article  Google Scholar 

  25. A. Alevra, D. Thomas, Neutron spectrometry in mixed fields: multisphere spectrometer. Radiat. Prot. Dosim. 107, 37–72 (2003). https://doi.org/10.1093/oxfordjournals.rpd.a0063848

    Article  Google Scholar 

  26. R. Bedogni, C. Domingo, A. Esposito et al., FRUIT: an operational tool for multisphere neutron spectrometry in workplaces. Nucl. Instrum. Methods A. 580, 1301–1309 (2007). https://doi.org/10.1016/j.nima.2007.07.033

    Article  Google Scholar 

  27. M. Matzke, Unfolding procedures. Radiat. Prot. Dosim. 107, 155–174 (2003). https://doi.org/10.1093/oxfordjournals.rpd.a006384

    Article  Google Scholar 

  28. C.S. Zaidins, J.B. Martin, F.M. Edwards, A least-squares technique for extracting neutron spectra from Bonner sphere data. Med. Phys. 5, 42–45 (1978). https://doi.org/10.1118/1.594464

    Article  Google Scholar 

  29. J. Cao, C. Jiang, Q. Yang et al., Verification of a fusion neutron diagnostic Bonner sphere spectrometer on measurement of a 241Am–Be neutron source. Nucl. Sci. Tech. 27, 127 (2016). https://doi.org/10.1007/s41365-016-0126-2

    Article  Google Scholar 

  30. A. Esposito, M. Nandy, Measurement and unfolding of neutron spectra using Bonner spheres. Radiat. Prot. Dosim. 110(1–4), 555–558 (2004). https://doi.org/10.1093/rpd/nch385

    Article  Google Scholar 

  31. W.Y. Hong, L.W. Yan, K.J. Zhao et al., Experimental observation of divertor configuration and ECRH on the HL-2A Tokamak. Nucl. Fusion. Plasma. Phys. 27(1), 7–11 (2007). https://doi.org/10.3969/j.issn.0254-6086.2007.01.002. (in Chinese)

    Article  Google Scholar 

  32. Z.M. Hu, X.F. Xie, Z.J. Chen et al., Monte Carlo simulation of a Bonner sphere spectrometer for application to the determination of neutron field in the experimental advanced superconducting Tokamak experimental hall. Rev. Sci. Instrum. 85, 11E417 (2014). https://doi.org/10.1063/1.4891163

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Bo-Wen Zheng.

Additional information

This work was supported by the National Natural Science Foundation of China (Nos. 11375195 and 11575184).

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zheng, BW., Jiang, CY., Liu, ZH. et al. Correction and verification of HL-2A Tokamak Bonner sphere spectrometer in monoenergetic neutron fields from 100 keV to 5 MeV. NUCL SCI TECH 30, 159 (2019). https://doi.org/10.1007/s41365-019-0689-9

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s41365-019-0689-9

Keywords

Navigation