Abstract
Calibrations were performed for three types of neutron ambient dose equivalent rate meters, i.e., Aloka TPS-451C (Hitachi), KSAR1U.06 (Baltic Scientific Instruments), and Model 12-4 (Ludlum), using a standard field of a 241Am–Be source. The measured total neutron ambient dose equivalent rates, \(H^*(10)_{\text{tot}}'\), were analyzed to obtain the direct neutron ambient dose equivalent rates, \(H^*(10)_{\text{dir}}'\), using the ISO 8529-2-recommended generalized-fit method, semiempirical fit method, and reduced-fitting method (RFM) fit methods. The calibration factor (CF), defined as the ratio between the conventional true value of the neutron ambient dose equivalent rates in a free field, \(H^*(10)_{\text{FF}}'\), and \(H^*(10)_{\text{dir}}'\), was evaluated as one of the important characteristics of the neutron meters in the present work. The fitting results show that the \(H^*(10)_{\text{dir}}'\) values of the meters are in good agreement within the theoretical data within 4%. The averaged CFs of the three neutron meters were evaluated as \(0.99 \pm 0.01\), \(1.00 \pm 0.03,\) and \(0.99 \pm 0.08\), respectively. The largest standard uncertainty of these values was determined to be approximately 18.47% (\(k=1\)). The standard uncertainty of the CFs obtained using the RFM method was less than 4.23% (\(k=1\)), which is the smallest uncertainty among the three methods.
Similar content being viewed by others
References
S.M. Jun, B.H. Kim, J.L. Kim et al., Calibration of spherical neutron measuring devices with a \(^{252}\)Cf source in the neutron calibration room of the KAERI. J. Nucl. Sci. Technol. 5, 286–289 (2008)
ISO 8529-2:2001 (E), Reference neutron radiations-part 2: calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field, Switzerland (2000)
T.N. Le, H.N. Tran, K.T. Nguyen et al., Neutron calibration field of a bare \(^{252}\)Cf source in Vietnam. Nucl. Eng. Technol. 49, 277–284 (2017). https://doi.org/10.1016/j.net.2016.07.011
T.N. Le, H.N. Tran, Q.N. Nguyen et al., Characterization of a neutron calibration field with 241Am–Be source using bonner sphere spectrometer. Appl. Radiat. Isot. 133, 68–74 (2018). https://doi.org/10.1016/j.apradiso.2017.12.012
S. Loreti, A. Pietropaolo, Assessment of the neutron emission anisotropy factor of a sealed Am–Be source by means of measurements and Monte Carlo simulations. Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 797, 201–205 (2015). https://doi.org/10.1016/j.nima.2015.06.047
H. Mazrou, T. Sidahmed, M. Allab, Neutron field characterisation of the OB26 CRNA irradiator in view of its use for calibration purposes. Radiat. Prot. Dosim. 141, 114–126 (2010). https://doi.org/10.1093/rpd/ncq166
Aloka TPS-451C-Hitachi, Neutron Survey Meter TPS-451C. http://www.hitachi.com/businesses/healthcare/products-support/radiation/surveymeter/tps451c/index.html. Accessed 11 Mar 2019
IAEA Nuclear Security Series No. 1, Technical and functional specifications for border monitoring equipment. International Atomic Energy Agency (2006)
KSAR1U.06-BSI, Neutron Search Detector KSAR1U.06. http://bsi.lv/en/products/neutron-search-detectors-infrare/neutron-search-detector-ksar1u06/. Accessed 11 Mar 2019
Model 12-4-Ludlum, Neutron Dose Ratemeter-Model 12-4. https://ludlums.com/products/all-products/product/model-12-4. Accessed 11 Mar 2019
G.F. Knoll, Radiation Detection and Measurement, 4th edn. (Wiley, New York, 2010)
T.N. Le, H.N. Tran, T.D. Duong et al., Evaluation of gamma contribution in a neutron calibration field of 241Am–Be source. Appl. Radiat. Isot. 133, 117–120 (2018). https://doi.org/10.1016/j.apradiso.2018.01.001
H. Kluge, K. Weise, J.B. Hunt, Calibration of neutron sensitive spherical devices with bare and D\(_2\)O-moderated \(^{252}\)Cf sources in rooms of different sizes. Radiat. Prot. Dosim. 32, 233–244 (1990). https://doi.org/10.1093/oxfordjournals.rpd.a080738
C.M. Eisenhauer, Review of scattering corrections for calibration of neutron instruments. Radiat. Prot. Dosim. 28, 253–262 (1989). https://doi.org/10.1093/oxfordjournals.rpd.a080514
C.M. Eisenhauer, J.B. Hunt, R. Schwartz, Calibration techniques for neutron personal dosimetry. Radiat. Prot. Dosim. 10, 43–57 (1985). https://doi.org/10.1093/oxfordjournals.rpd.a079410
H. Schraube, F. Grünauer, G. Burger, Calibration problems with neutron moderator detectors, in Proceeding of Symposium on Neutron Monitoring for Radiation Protection Purposes (1972), pp. 453–464
H.R. Vega-Carrillo, E. Manzanares-Acuña, M. Pilar Iñiguez et al., Spectrum of isotopic neutron sources inside concrete wall spherical cavities. Radiat. Meas. 42, 1373–1379 (2007). https://doi.org/10.1016/j.radmeas.2007.06.006
H.R. Vega-Carrillo, E. Manzanares-Acuña, M. Pilar Iñiguez et al., Study of room-return neutrons. Radiat. Meas. 42, 413–419 (2007). https://doi.org/10.1016/j.radmeas.2007.01.036
Author information
Authors and Affiliations
Corresponding author
Additional information
This work was supported by the Ministry of Science and Technology of Vietnam under Grant 07/HĐ/ĐTCB.
Rights and permissions
About this article
Cite this article
Le, T.N., Hoang, S.M.T., Nguyen, Q.N. et al. Evaluation of the calibration factors of neutron dose rate meters in a 241Am–Be neutron field. NUCL SCI TECH 30, 133 (2019). https://doi.org/10.1007/s41365-019-0654-7
Received:
Revised:
Accepted:
Published:
DOI: https://doi.org/10.1007/s41365-019-0654-7