Bending response of cold-formed steel built-up beams with overlapped flanges in stiffened channels

  • Technical paper
  • Published:
Innovative Infrastructure Solutions Aims and scope Submit manuscript

Abstract

Mono-section members may not fulfil the structural requirements from strength or serviceability considerations. Built-up members are successful at producing sufficient resistance to high load demands, and their effectiveness is dictated mainly by the robustness of the designing and detailing of the built-up sections. The past findings on built-up beams with closed sections have been limited. This study aimed to explore the bending response of cold-formed steel (CFS) built-up beams constructed using channels that were intermediately stiffened in the web region through an experimental analysis. The built-up specimens were formed by connecting the stiffened channels in the face-to-face arrangement by overlapping the flanges over one another, thus doubling the thickness of the outermost fibers, subjected to extreme compressive stresses due to flexure. The stiffened channels were fastened by means of self-drilling screws, which were connected at the center of the flange width, along the beams’ lengths, on both the tension and compression zones. All the specimens adhered to simply supported boundary conditions. The sectional compactness of the stiffened channels and the loading pattern were varied in the specimens, and their effect on the bending response was noted. All the specimens had nearly the same cross-sectional aspect ratio. Tensile coupon tests were performed before the specimens’ bending tests were conducted to bring out the mechanical properties of the steel sheets adopted for fabricating the various specimens. Also, the test strengths were compared against the theoretical strengths that were developed using relevant European and North American Specifications. It was confirmed that both the sectional compactness as well as the loading type adopted had an influence on the bending strength of CFS built-up beams with overlapped flanges in stiffened channels. Both the design standards resulted in unconservative predictions, with the North American Specification being more unconservative.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17

Similar content being viewed by others

References

  1. Saeed MK, Alhakeem AA (2021) Selection of optimum structural roof system in Saudi Arabia for a conference hall without interior columns in terms of cost and feasibility. Innov Infrastruct Solut 6(8). doi:https://doi.org/10.1007/s41062-020-00377-w

  2. Raut KV, Morkhade SG, Khartode RR, Ahiwale DD (2020) Experimental study on flexural behavior of light steel hollow flange beam with various stiffening arrangements. Innov Infrastruct Solut 5(90). doi:https://doi.org/10.1007/s41062-020-00345-4

  3. Yu J, Becquea J, Hajirasoulihaa I, Mojtabaei SM, Lim JBP (2018) Development of optimum cold-formed steel sections for maximum energy dissipation in uniaxial bending. Eng Struct 161:55–67

    Article  Google Scholar 

  4. Sani MSHM, Muftah F, Ismail MI (2018) Testing and analysis of cold-formed steel channel section with notch. Int J Geomate 14(43):42–49

    Google Scholar 

  5. Siahaan R, Keerthan P, Mahendren M (2018) Section moment capacity design rules for rivet fastened rectangular hollow flange channel beams. Thin-Walled Struct 127:781–797

    Article  Google Scholar 

  6. Magnucki K, Paczos P, Kasprzak J (2010) Elastic buckling of cold-formed thin-walled channel beams with drop flanges. J Struct Eng-ASCE 136(7):886–896

    Article  Google Scholar 

  7. Grenda M, Paczos P (2019) Experimental and numerical study of local stability of non-standard thin-walled channel beams. J Theor Appl Mech 57(3):549–562

    Article  Google Scholar 

  8. Yang Y, Lui EM (2012) Behavior and design of steel I-beams with inclined stiffeners. Steel Compos Struct 12(3):183–205

    Article  Google Scholar 

  9. Dar MA, Dar AR, Yusuf M, Raju J (2015) Experimental study on innovative sections for cold formed steel beams. Steel Compos Struct 19(6):1599–1610

    Article  Google Scholar 

  10. Dar MA, Subramanian N, Mir A, Dar AR, Anbaasu M, Lim JBP (2020) Efficient cross-sectional profiling of built up CFS beams for improved flexural performance. Steel Compos Struct 34(3):333–345

    Google Scholar 

  11. Dar MA, Subramanian N, Rather AI, Dar A, Lim JBP, Anbarasu M, Roy K (2019) Effect of angle stiffeners on the flexural strength and stiffness of cold-formed steel beams. Steel Compos Struct 33(2):225–243

    Google Scholar 

  12. Dar MA, Subramanian N, Dar AR, Anbarasu M, Lim JB, Mir A (2019) Behaviour of partly stiffened cold-formed steel built-up beams: Experimental investigation and numerical validation. Adv Struct Eng 22(1):172–186

    Article  Google Scholar 

  13. Dar MA, Subramanian N, Dar DA, Dar AR, Anbarasu M, Lim JBP, Mahjoubi S (2020) Flexural strength of cold-formed steel built-up composite beams with rectangular compression flanges. Steel Compos Struct 34(2):171–188

    Google Scholar 

  14. Dar MA, Subramanian N, Dar AR, Anbarasu M, Lim JBP (2018) Structural Performance of cold-formed steel composite beams. Steel Compos Struct 27(5):545–554

    Google Scholar 

  15. Dar MA, Subramanian N, Dar AR, Majid M, Haseeb M, Tahoor M (2019) Structural efficiency of various strengthening schemes for cold-formed steel beams: effect of global imperfections. Steel Compos Struct 30(4):393–403

    Google Scholar 

  16. Divahar R, Joanna PS (2018) Numerical simulation and experimental investigation on static behavior of cold formed steel beam with trapezoidally corrugated web by varying depth-thickness ratio. Asian J Civ Eng 19(2):121–137

    Article  Google Scholar 

  17. Faridmehr I, Osman MH, Tahir MM, Azimi M, Gholami M (2016) Behaviour and design of cold-formed steel C-sections with cover plates under bending. Int J Steel Struct 16(2):587–600

    Article  Google Scholar 

  18. Faridmehr I, Tahir MM, Osman MH, Nejad AF, Hodjati R (2015) An experimental investigation of stiffened cold-formed C-channels in pure bending and primarily shear conditions. Thin-Walled Struct 96:39–48

    Article  Google Scholar 

  19. Ghannam M (2019) Bending moment capacity of cold-formed steel built-up beams. Int J Steel Struct 19(2):660–671

    Article  Google Scholar 

  20. Muftah F, Sani MSHM, Kamal MMM (2019) Flexural strength behaviour of bolted built-up cold-formed steel beam with outstand and extended stiffener. Int J Steel Struct 19(3):719–732

    Article  Google Scholar 

  21. Anbarasu M, Dar MA, Ghowsi AF, Dar AR (2021) Flexural behaviour of cover plated CFS built-up beams composed of lipped channels: comparison of test and design strengths. Structures 30:294–304. https://doi.org/10.1016/j.istruc.2020.12.088

    Article  Google Scholar 

  22. Wang L, Young B (2016) Behavior of cold-formed steel built-up sections with intermediate stiffeners under bending. I: tests and numerical validation. J Struct Eng-ASCE 142(3): https://doi.org/10.1061/(ASCE)ST.1943-541X.0001428

  23. Anbarasu M (2019) Simulation of flexural behaviour and design of cold-formed steel closed built-up beams composed of two sigma sections for local buckling. Eng Struct 191:549–562

    Article  Google Scholar 

  24. AISI S-100, North American specification for the design of cold-formed steel structural members, AISI Standard, Washington, DC, 2016

  25. EC3.Eurocode3. Design of steel structures. Part1–3: General rules – Supplementary rules for cold-formed members and sheeting. BS EN1993-1-3, Brussels 2006: European Committee for Standardization

  26. IS 1608-2005. Indian Standard- Metallic Materials - Tensile Testing at Ambient Temperature, Bureau of Indian Standards, New Delhi, India 2005

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. R. Dar.

Ethics declarations

Conflict of interest

The author declared no potential conflicts of interest with respect to the research, authorship and/or publication of this article.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Dar, A.R. Bending response of cold-formed steel built-up beams with overlapped flanges in stiffened channels. Innov. Infrastruct. Solut. 6, 175 (2021). https://doi.org/10.1007/s41062-021-00546-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s41062-021-00546-5

Keywords

Navigation