The thermohydraulic characteristics of turbulent flow of air (Pr 0.7) through circular tube with short-length and full-length twisted-tape turbulators inserts have been studied experimentally. Also, heat transfer performance for different values of the twist ratio, tape thickness ratio and diameter ratio are investigated for Reynolds numbers within the range 6000–20,000. The full-length twisted tape enhances heat transfer more than those of short-length twisted tapes. Heat transfer and pressure drop tests were carried out in brass channels. The channel with twisted tape inserts specifies that the use of tapes augments heat transfer mostly, which is complemented by a greater friction penalty. The thermohydraulic performance of the problem under study has been assessed. It is observed that by using full-length twisted tape at constant pumping power, up to 27% heat duty rises in comparison with short-length twisted tape. Similarly, by using full-length twisted tape at heat duty, up to 33% pumping power increases in comparison with short-length twisted tape.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

Abbreviations

A :

Heat transfer area [πDL (m2)]

A 0 :

Plain duct flow cross-sectional area (m2)

Cp:

Constant pressure specific heat (J/kg K)

D :

Internal diameter of the plain channel (m)

D h :

Hydraulic diameter of the test duct = 4A0/P (m)

f :

Fully developed Fanning friction factor (dimensionless)

FLTT:

Full-length twisted-tape

FLHT:

Full-length helical tape

g :

Gravitational acceleration (m/s2)

Gr :

Grashof number = gβρ2D3hΔTw/μ2 (dimensionless)

H :

Pitch for 180° rotation of twisted tape (m)

h z :

Axially local heat transfer coefficient [W/(m2 K)]

k :

Fluid thermal conductivity [W/(mK)]

L :

Length of twisted-tape (m)

m :

Mass flow rate (kg/min)

Nu m :

Axially averaged Nusselt number = \(\frac{1}{L}\int\limits_{0}^{L} {\frac{{h_{\text{z}} D_{\text{h}} {\text{d}}z}}{k}}\) (dimensionless)

ΔPz :

Pressure drop (mm)

P :

Wetted perimeter in the particular cross section of the duct (m)

Pr :

Fluid Prandtl number = \({\raise0.7ex\hbox{${\mu C_{\text{p}} }$} \!\mathord{\left/ {\vphantom {{\mu C_{\text{p}} } k}}\right.\kern-0pt} \!\lower0.7ex\hbox{$k$}}\) (dimensionless)

Ra :

Rayleigh number = Gr·Pr

Re :

Reynolds number based on plain channel diameter (dimensionless)

T :

Temperature (K)

SLTT:

Short-length twisted tape

Tw :

Wall to fluid bulk temperature difference (K)

X :

Prn, the value of n depends on the exponent of Pr in the correlation

Y :

\(\left( {\frac{{\mu_{\text{b}} }}{{\mu_{\text{w}} }}} \right)^{ - 0.14} \times \frac{1}{5.172}\)

y :

Twist ratio (dimensionless)

β :

Coefficient of isobaric thermal expansion (K−1)

δ :

Tape thickness ratio [t/D (m)]

µ :

Fluid dynamic viscosity (kg/ms)

ρ :

Density of the fluid (kg/m3)

ax:

At axial flow condition

b :

At bulk fluid temperature

m :

Axially averaged

sw:

At swirl flow condition

w :

At duct wall temperature, with

z :

Local value

References

  • AI-Fahed S, Chakroun W (1996) Effect of tube tape clearance on heat transfer for fully developed turbulent flow in a horizontal isothermal tube. Int J Heat Fluid Flow 17(2):173–178

    Article  Google Scholar 

  • Balachandar C, Arunkumar S, Madhumitha R, Venkatesan M (2018) MANFIS–GA heat transfer analysis and optimization of fins with elliptical perforation. Iran J Sci Technol Trans Mech Eng. https://doi.org/10.1007/s40997-018-0179-4

    Article  Google Scholar 

  • Bergles AE, Blumenkrantz AR, Taborek J (1974) Performance evaluation criteria for enhanced heat transfer surfaces. Paper FC 6.3. In: Proceedings of the 5th international heat transfer conference, vol II, Tokyo, pp 239–243

  • Bhattacharyya S, Saha SK (2012) Thermohydraulics of laminar flow through a circular tube having integral helical rib roughness and fitted with centre cleared twisted-tape. Exp Therm Fluid Sci 42:154–162

    Article  Google Scholar 

  • Bhattacharyya S, Saha S, Saha SK (2013) Laminar flow heat transfer enhancement in a circular tube having integral spiral rib roughness and fitted with centre cleared twisted-tape. Exp Therm Fluid Sci 44:727–735

    Article  Google Scholar 

  • Bhattacharyya S, Chattopadhyay H, Haldar A (2018) Design of twisted tape turbulator at different entrance angle for heat transfer enhancement in a solar heater. Beni-Suef Univ J Basic Appl Sci 7(1):118–126

    Article  Google Scholar 

  • Eiamsa-ard S, Promvonge P (2005) Enhancement of heat transfer in a tube with regularly-spaced helical tape swirl generators. Sol Energy 78:483–494

    Article  Google Scholar 

  • Eiamsa-ard S, Thianpong C, Eiamsa-ard P, Promvonge P (2009) Convective heat transfer in a circular tube with short-length twisted tape insert. Int Commun Heat Mass Transf 36:365–371

    Article  Google Scholar 

  • Ghajar AJ, Tang CC, Cook WL (2010) Experimental investigation of friction factor in the transition region for water flow in minitubes and microtubes. Heat Transf Eng 31(8):646–657

    Article  Google Scholar 

  • Manglik RM, Bergles AE (1994) Fully developed laminar heat transfer in circular-segment ducts with uniform wall temperature. Numer Heat Transf Part A Appl 26:499–519

    Article  Google Scholar 

  • Meyer JP, Abolarin SM (2018) Heat transfer and pressure drop in the transitional flow regime for a smooth circular tube with twisted tape inserts and a square edge inlet. Int J Heat Mass Transf 117:11–29

    Article  Google Scholar 

  • Meyer JP, Olivier JA (2011) Transitional flow inside enhanced tubes for fully developed and developing flow with different types of inlet disturbances: part I—adiabatic pressure drops. Int J Heat Mass Transf 54(7–8):1587–1597

    Article  Google Scholar 

  • Mohammadiun H, Amerian V, Mohammadiun M, Rahimi AB (2017) Similarity solution of axisymmetric stagnation-point flow and heat transfer of a nanofluid on a stationary cylinder with constant wall temperature. Iran J Sci Technol Trans Mech Eng 41:91–95

    Article  Google Scholar 

  • Ozisik MN (1985) Heat transfer. McGraw-Hill, New York

    MATH  Google Scholar 

  • Rahimi M, Soran RA (2017) Numerical analysis of heat transfer and flow field due to slot air jet impingement for the cases of moving plate and moving nozzle. Iran J Sci Technol Trans Mech Eng 41:217

    Article  Google Scholar 

  • Roy S, Saha SK (2015) Thermal and friction characteristics of laminar flow through a circular duct having helical screw-tape with oblique teeth inserts and wire coil inserts. Exp Therm Fluid Sci 68:733–743

    Article  Google Scholar 

  • Sabet GS, Pavithran S, Iran Kulkarni RR (2017) comparison of heat transfer enhancement in a diffuser by inserting wing vortex generators and protrusions. Iran J Sci Technol Trans Mech Eng. https://doi.org/10.1007/s40997-017-0084-2

    Article  Google Scholar 

  • Saha SK (2010) Thermohydraulics of turbulent flow through rectangular and square ducts with axial corrugation roughness and twisted tapes with and without oblique teeth. Exp Therm Fluid Sci 34(6):744–752

    Article  Google Scholar 

  • Saha SK (2011) Thermohydraulics of turbulent flow through square and rectangular ducts with transverse ribs and twisted tapes with and without oblique teeth. J Enhanc Heat Transf 18(4):281–293

    Article  Google Scholar 

  • Saha SK, Bhattacharyya S, Pal PK (2012) Thermo-hydraulics of laminar flow of viscous oil through a circular tube having integral spiral rib roughness and fitted with centre-cleared twisted tape. Exp Therm Fluid Sci 41:121–129

    Article  Google Scholar 

  • Sheikholeslami M (2018a) Numerical investigation for CuO–H2O nanofluid flow in a porous channel with magnetic field using mesoscopic method. J Mol Liq 249:739–746

    Article  Google Scholar 

  • Sheikholeslami M (2018b) Numerical investigation of nanofluid free convection under the influence of electric field in a porous enclosure. J Mol Liq 249:1212–1221

    Article  Google Scholar 

  • Sheikholeslami M, Ganji DD (2016a) Heat transfer improvement in a double pipe heat exchanger by means of perforated turbulators. Energy Convers Manag 127:112–123

    Article  Google Scholar 

  • Sheikholeslami M, Ganji DD (2016b) Heat transfer enhancement in an air to water heat exchanger with discontinuous helical turbulators; experimental and numerical studies. Energy 116:341–352

    Article  Google Scholar 

  • Sheikholeslami M, Rokni HB (2018) Numerical simulation for impact of Coulomb force on nanofluid heat transfer in a porous enclosure in presence of thermal radiation. Int J Heat Mass Transf 118:823–831

    Article  Google Scholar 

  • Sheikholeslami M, Seyednezhad M (2018) Simulation of nanofluid flow and natural convection in a porous media under the influence of electric field using CVFEM. Int J Heat Mass Transf 120:772–781

    Article  Google Scholar 

  • Sheikholeslami M, Shehzad SA (2018) Simulation of water based nanofluid convective flow inside a porous enclosure via non-equilibrium model. Int J Heat Mass Transf 120:1200–1212

    Article  Google Scholar 

  • Sheikholeslami M, Darzi M, Sadoughi MK (2018) Heat transfer improvement and pressure drop during condensation of refrigerant-based nanofluid; an experimental procedure. Int J Heat Mass Transf 122:643–650

    Article  Google Scholar 

  • Sivashanmugam P, Suresh S (2006) Experimental studies on heat transfer and friction factor characteristics of laminar flow through a circular tube fitted with helical screw-tape inserts. Appl Therm Eng 26:1990–1997

    Article  Google Scholar 

  • Sivashanmugam P, Suresh S (2007a) Experimental studies on heat transfer and friction factor characteristics of laminar flow through a circular tube fitted with regularly spaced helical screw-tape inserts. Exp Therm Fluid Sci 31:301–308

    Article  Google Scholar 

  • Sivashanmugam P, Suresh S (2007b) Experimental studies on heat transfer and friction factor characteristics of turbulent flow through a circular tube fitted with regularly spaced helical screw-tape inserts. Appl Therm Eng 27:1311–1319

    Article  Google Scholar 

  • Sivashanmugam P, Suresh S (2007c) Experimental studies on heat transfer and friction factor characteristics of turbulent flow through a circular tube fitted with helical screw-tape inserts. Chem Eng Process 46:1292–1298

    Article  Google Scholar 

  • Suresh KP, Mahanta P, Dewan A (2004) Study of heat transfer and pressure drop in a large hydraulic diameter annulus. In: 17th national heat and mass transfer conference and 6th ISHMT/ASME, heat and mass transfer conference. Indira Gandhi Centre for Atomic Research, Kalpakkam, pp 62–66

  • Tiwari M, Saha SK (2015) Thermohydraulics of laminar flow through a circular tube with transverse ribs and twisted tapes. ASME J Therm Sci Eng Appl 7(4):041009. https://doi.org/10.1115/1.4030792

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Suvanjan Bhattacharyya.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Bhattacharyya, S. Fluid Flow and Heat Transfer in a Heat Exchanger Channel with Short-Length Twisted Tape Turbulator Inserts. Iran J Sci Technol Trans Mech Eng 44, 217–227 (2020). https://doi.org/10.1007/s40997-018-0251-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s40997-018-0251-0

Keywords

Navigation